A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou...A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed.The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters,and four sets of detector telescopes(including doublesided silicon strip detectors) are placed systematically with the beam line,incorporating with Monte Carlo simulations.The data of ^(16)O on ^(89)Y target were analyzed to compare with the simulation results.It is found that the simulated distribution is agreeable with the experimental data.By assuming the pure Rutherford scattering at small scattering angles,the angular distribution of elastic scattering of^(16)O+^(89)Y at low energies can be reasonably obtained.It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.展开更多
A β-delayed particle decay beam like 9C has been recognized as a double irradiation source, i.e. the external beam radiation itself and the delayed low-energy particles emitted internally. A radioactive 9C-ion beam, ...A β-delayed particle decay beam like 9C has been recognized as a double irradiation source, i.e. the external beam radiation itself and the delayed low-energy particles emitted internally. A radioactive 9C-ion beam, therefore, is considered to be very useful in cancer radiation therapy. To explore the potential importance of radioactive 9C-ion beams in cancer therapy, radiobiological experiments using a 9C beam supplied by the secondary beam line (SBL) at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan were carried out.展开更多
基金Supported by the National Natural Science Foundation of China(Nos.11475013,11175011,11035007)
文摘A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed.The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters,and four sets of detector telescopes(including doublesided silicon strip detectors) are placed systematically with the beam line,incorporating with Monte Carlo simulations.The data of ^(16)O on ^(89)Y target were analyzed to compare with the simulation results.It is found that the simulated distribution is agreeable with the experimental data.By assuming the pure Rutherford scattering at small scattering angles,the angular distribution of elastic scattering of^(16)O+^(89)Y at low energies can be reasonably obtained.It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.
文摘A β-delayed particle decay beam like 9C has been recognized as a double irradiation source, i.e. the external beam radiation itself and the delayed low-energy particles emitted internally. A radioactive 9C-ion beam, therefore, is considered to be very useful in cancer radiation therapy. To explore the potential importance of radioactive 9C-ion beams in cancer therapy, radiobiological experiments using a 9C beam supplied by the secondary beam line (SBL) at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan were carried out.