期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Optically stimulated luminescence dosimeter based on CaS:Eu,Sm 被引量:4
1
作者 LIU Yanping CHEN Zhaoyang +6 位作者 BA Weizhen FAN Yanwei GUO Qi YU Xuefeng CHANG Aiming LU Wu DU Yanzhao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第2期113-116,共4页
Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (O... Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions. 展开更多
关键词 刺激性发光 辐射检测 辐射放射量测定器
下载PDF
A study on Fricke-PVA-xylenol orange hydrogel dosimeter for E-beam radiotherapy
2
作者 CAO Fangqi YANG Liming +6 位作者 CHEN Jie LIN Han FAN Jinchen RONG Liang LUO Wenyun ZHA Yuanzi WU Guohua 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第3期152-156,共5页
A Fricke-PVA-xylenol orange (FPX) hydrogel dosimeter, in good transparency, was prepared by physical crosslinking for three-dimensional dose measurements. The process of mixing the chemical dosimeter with the PVA solu... A Fricke-PVA-xylenol orange (FPX) hydrogel dosimeter, in good transparency, was prepared by physical crosslinking for three-dimensional dose measurements. The process of mixing the chemical dosimeter with the PVA solution was carried out at room temperature, which reduced the influence of auto-oxidation rate. Gradation in color was obviously observed with different distance from the radiation source after 6 MeV electron beam irradiation for radiotherapy. The effects of irradiation dose and three components of the FPX gel dosimeter, i.e. ferrous ions, xylenol orange (XO) and sulphuric acid on sensitivity and stability of dose response were investigated by UV-vis spectropho-tometric measurement. The dose response of the FPX gel dosimeter was linear in the range 0~2.0 Gy. The orthogonal test was employed to find the optimal composition of the gel dosimeter with a sensitivity of about 0.095 cm-1·Gy-1. It was found that XO concentration greatly affected the sensitivity of dose response and lower concentrations of the ferrous ion and XO gave higher sensitivity within the range 0~2.0 Gy. 展开更多
关键词 PVA 放射量测定器 FPX 凝胶体 核技术
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部