期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
纳秒脉冲下单间隙伪火花放电特性 被引量:5
1
作者 张佳 赵军平 张乔根 《强激光与粒子束》 EI CAS CSCD 北大核心 2014年第4期211-214,共4页
采用单间隙伪火花放电装置,研究了纳秒脉冲下气压、间隙距离和小孔直径对伪火花放电特性的影响。研究结果表明,纳秒脉冲下伪火花放电电压随着气压、间隙距离和小孔直径的增加而减小。通过数值拟合,得到了放电电压与气压、间隙距离和小... 采用单间隙伪火花放电装置,研究了纳秒脉冲下气压、间隙距离和小孔直径对伪火花放电特性的影响。研究结果表明,纳秒脉冲下伪火花放电电压随着气压、间隙距离和小孔直径的增加而减小。通过数值拟合,得到了放电电压与气压、间隙距离和小孔直径间的经验公式。放电电压随着气压、间隙距离和小孔直径的增加而减小,衰减系数分别为0.76,0.39和0.39。 展开更多
关键词 纳秒脉冲 单间隙伪火花放电 放电电压特性 间隙距离 小孔直径
下载PDF
Study of partial discharge characteristics at repetitive square voltages based on UHF method 被引量:15
2
作者 WANG Peng WU GuangNing +2 位作者 GAO Bo LUO Yang CAO KaiJiang 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第1期262-270,共9页
Due to overvoltage produced by inverter output,inverter-fed motor insulation systems often experience fast electrical aging process,especially when partial discharge(PD) is incepted.Before putting into use,the PD dete... Due to overvoltage produced by inverter output,inverter-fed motor insulation systems often experience fast electrical aging process,especially when partial discharge(PD) is incepted.Before putting into use,the PD detection should be performed on inverter-fed motors at repetitive square voltages to avoid the PD caused insulation deterioration when the motors are collected to inverters having specific characteristics.However,unlike PD tests at AC/DC voltages proposed in IEC 60270,the PD detection at repetitive square voltages is much more complex because of serious interference generated by impulse generator.To solve the problem,ultra-high frequency(UHF) method seems recommendable for its preferable signal-to-noise ratio(SNR).The chief aim of this study is to investigate PD pulse and statistical characteristics of turn-to-turn insulation for inverter-fed traction motors.A square-shaped Archimedes antenna,specially designed for the PD detection at repetitive square voltages of fast rise times,was used to perform PD tests on turn-to-turn insulation models.Time and frequency analysis results indicate that energy component of generator disturbance and PD pulses are mainly distributed in the 0-0.5 GHz and 0.6-1.5 GHz range,respectively.Based on the results,suitable filter was designed for power disturbance suppression.Additionally,resorting to the sensor unit(i.e.antenna and filter) and the PD test system,the PD statistical features at square voltages of different frequencies were obtained.Experimental results show that higher frequency will give rise,statistically,to PD of lower magnitudes distributing at smaller phases.A reasonable interpretation of this phenomenon was presented.Lastly,according to the PD statistical features,some suggestions for the PD detection system design,generator parameter optimization and the PD pulse extracting were given.The results of this work would be beneficial to the increase of the sensitivity when performing the PD detection on insulation systems for inverter-fed motors at repetitive square voltages and thus,improving the reliability of inverter-fed motors. 展开更多
关键词 inverter-fed motors insulation system partial discharge UHF square voltage ANTENNA FILTER
原文传递
上一页 1 下一页 到第