A novel numerical algorithm of fault location estimation for four-line fault without ground connection involving phases from each of the parallel lines is presented in this paper. It is based on one-terminal voltage a...A novel numerical algorithm of fault location estimation for four-line fault without ground connection involving phases from each of the parallel lines is presented in this paper. It is based on one-terminal voltage and current data. The loop and nodal equations comparing faulted phase to non-faulted phase of two-parallel lines are introduced in the fault location estimation model, in which the source impedance of a remote end is not involved. The effects of load flow and fault resistance on the accuracy of fault location are effectively eliminated, therefore a precise algorithm of locating fault is derived. The algorithm is demonstrated by digital computer simulations.展开更多
In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline....In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline. The main methods for the detection are UHF signal amplitude difference (DOA) and time difference (TOF). We analyze the localization error by using TE and TEM component and high order TE mode component in electromagnetic coaxial wave guide theory. Research and field test prove the DOA detection error can meet the requirements of real-time online diagnosis and for history tracking analysis. The error of TOF detection method can be controlled within 3% and can be applied to the site.展开更多
A novel single-ended online fault location algorithm is investigated for DC distribution networks. The proposed algorithm calculates the fault distance based on the characteristics of the voltage resonance. The Prony&...A novel single-ended online fault location algorithm is investigated for DC distribution networks. The proposed algorithm calculates the fault distance based on the characteristics of the voltage resonance. The Prony's method is introduced to extract the characteristics. A novel method is proposed to solve the pseudo dual-root problem in the calculation process. The multiple data windows are adopted to enhance the robustness of the proposed algorithm. An index is proposed to evaluate the accuracy and validity of the results derived from the various data windows. The performances of the proposed algorithm in different fault scenarios were evaluated using the PSCAD/EMTDC simulations. The results show that the algorithm can locate the faults with transient resistance using the 1.6 ms data of the DC-side voltage after a fault inception and offers a good precision.展开更多
文摘A novel numerical algorithm of fault location estimation for four-line fault without ground connection involving phases from each of the parallel lines is presented in this paper. It is based on one-terminal voltage and current data. The loop and nodal equations comparing faulted phase to non-faulted phase of two-parallel lines are introduced in the fault location estimation model, in which the source impedance of a remote end is not involved. The effects of load flow and fault resistance on the accuracy of fault location are effectively eliminated, therefore a precise algorithm of locating fault is derived. The algorithm is demonstrated by digital computer simulations.
文摘In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline. The main methods for the detection are UHF signal amplitude difference (DOA) and time difference (TOF). We analyze the localization error by using TE and TEM component and high order TE mode component in electromagnetic coaxial wave guide theory. Research and field test prove the DOA detection error can meet the requirements of real-time online diagnosis and for history tracking analysis. The error of TOF detection method can be controlled within 3% and can be applied to the site.
基金supported by the National Basic Research Program of China("973" Project)(Grant No.2012CB215206)the National Natural Science Foundation of China(Grant Nos.51407067&51222703)the "111" Project of China(Grant No.B08013)
文摘A novel single-ended online fault location algorithm is investigated for DC distribution networks. The proposed algorithm calculates the fault distance based on the characteristics of the voltage resonance. The Prony's method is introduced to extract the characteristics. A novel method is proposed to solve the pseudo dual-root problem in the calculation process. The multiple data windows are adopted to enhance the robustness of the proposed algorithm. An index is proposed to evaluate the accuracy and validity of the results derived from the various data windows. The performances of the proposed algorithm in different fault scenarios were evaluated using the PSCAD/EMTDC simulations. The results show that the algorithm can locate the faults with transient resistance using the 1.6 ms data of the DC-side voltage after a fault inception and offers a good precision.