基于本地电压比瞬量的直流短路故障检测与定位方法研究 被引量:5
1
作者 王静 孙谦浩 +3 位作者 刘国伟 赵宇明 代少君 熊天龙 《可再生能源》 CAS CSCD 北大核心 2021年第12期1693-1698,共6页
文章通过分析与模块化多电平换流器(Modular Multilevel Converter, MMC)相连的直流线路的短路故障特性,提出了一种基于故障限流电抗器两端电压比瞬时值的故障检测与定位方法,利用故障限流电抗器稳态与故障时两端电压比值的不同,可以迅... 文章通过分析与模块化多电平换流器(Modular Multilevel Converter, MMC)相连的直流线路的短路故障特性,提出了一种基于故障限流电抗器两端电压比瞬时值的故障检测与定位方法,利用故障限流电抗器稳态与故障时两端电压比值的不同,可以迅速地对短路故障进行判断与定位。由于所提方法仅依赖于各换流站本地的电压测量值而无需通信,因此相比于行波定位法与纵联保护法,可靠性与经济性更高、技术难度更低。同时,由于故障判据仅依赖于电压比在故障瞬间的值,而与故障后的变化特性无关,所提方法对故障的检测与定位更加快速,且可以较好地消除故障过渡电阻对定位精度的影响。最后,基于MATLAB/Simulink的仿真模型,验证了所提方法的正确性与有效性。 展开更多
关键词 MMC 故障限流电抗器 本地电压比瞬时值 短路故障分析 故障定位
下载PDF
The Application of the Fault Current Limiters in Power Distribution System
2
作者 T. Madiba W. Siti A.A. Jimoh 《Journal of Energy and Power Engineering》 2011年第12期1205-1212,共8页
In this paper, an application of fault current limiter-thyristor controller series reactor (FCL-TCSR) in the distribution network is presented in order to minimize the peak value of current during the fault conditio... In this paper, an application of fault current limiter-thyristor controller series reactor (FCL-TCSR) in the distribution network is presented in order to minimize the peak value of current during the fault condition. This application considers a single fault current limiting action but can also be applied for a three phase system. The maximum contribution of FCL-TCSR quickly clears the abnormal current in the power distribution system when a fault condition occurs. Using a mathematical model of FCL-TCSR, the impact of series impedance used to adjust the amplitude of the fault current action is demonstrated. The performance of the load with the impedance and load in series is also analyzed. 展开更多
关键词 FCL-TCSR distribution network limhing action mathematical model amplitude of the abnormal current.
下载PDF
Directional Overcurrent Relays Coordination Restoration by Reducing Minimum Fault Current Limiter Impedance
3
作者 Saadoun Abdel Aziz Mostafa DoaaKhalil Ibrahim Essam El-Din Abo El-Zahab 《Journal of Energy and Power Engineering》 2014年第6期1132-1141,共10页
FCL (fault current limiter) is used to solve relays miscoordination problem arises from DG (distributed generation) installation. In most published researches, different optimization methods are developed to obtai... FCL (fault current limiter) is used to solve relays miscoordination problem arises from DG (distributed generation) installation. In most published researches, different optimization methods are developed to obtain optimal relay settings to achieve coordination in case of not installing DG, then depending on the achieved optimal obtained relay settings, FCL impedance is deduced to ensure relays coordination restoration in case of installing DG. Based on original optimal relay settings, obtained FCL impedance is not the minimum one required to achieve relay coordination. The contribution of this paper is the generation of multi sets of original relay settings that increase the possibility of finding FCL impedance of minimum value which is lower than the calculated value based on original optimal relay settings. The proposed method achieves better economic target by reducing FCL impedance. The proposed approach is implemented and tested on IEEE-39 bus test system. 展开更多
关键词 FCL (fault current limiter) IP (pickup current setting) relays coordination TDS (time-dial setting).
下载PDF