When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor...When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor current mode. To solve this problem, this paper proposes a PFC control system, which can operate with load fluctuations up to 1 000 W by using duty cycle feed-forward control theory to achieve smooth switching mode. The duty cycles in the next period of the control system are pre-estimated in the current cycle, which enhances the speeds of AD samplers and switching frequency, and reduces the cost and volume of the equipment to some extent. Introductions of system decoupling and feed-forward of input-voltage greatly improve the system performance. Both theoretical simulation and experimental results prove the advantage of the proposed scheme.展开更多
A 10-bit single-slope analog-to-digital converter (ADC) for time-delay-integration CMOS image sensor was proposed. A programmable ramp generator was applied to accomplish the error calibration and improve the linearit...A 10-bit single-slope analog-to-digital converter (ADC) for time-delay-integration CMOS image sensor was proposed. A programmable ramp generator was applied to accomplish the error calibration and improve the linearity. The ADC was fabricated in a 180 nm 1P4M CMOS process. Experimental results indicate that the differential nonlinearity and integral nonlinearity were 0.51/-0.53 LSB and 0.63/-0.71 LSB, respectively. The sampling rate of the ADC was 32 kHz.展开更多
基金Supported by the National Basic Research Program of China("973"Program,No.2009CB219700)
文摘When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor current mode. To solve this problem, this paper proposes a PFC control system, which can operate with load fluctuations up to 1 000 W by using duty cycle feed-forward control theory to achieve smooth switching mode. The duty cycles in the next period of the control system are pre-estimated in the current cycle, which enhances the speeds of AD samplers and switching frequency, and reduces the cost and volume of the equipment to some extent. Introductions of system decoupling and feed-forward of input-voltage greatly improve the system performance. Both theoretical simulation and experimental results prove the advantage of the proposed scheme.
基金Supported by National Natural Science Foundation of China (No. 61036004 and No. 61076024)
文摘A 10-bit single-slope analog-to-digital converter (ADC) for time-delay-integration CMOS image sensor was proposed. A programmable ramp generator was applied to accomplish the error calibration and improve the linearity. The ADC was fabricated in a 180 nm 1P4M CMOS process. Experimental results indicate that the differential nonlinearity and integral nonlinearity were 0.51/-0.53 LSB and 0.63/-0.71 LSB, respectively. The sampling rate of the ADC was 32 kHz.