In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock...In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock-in amplifier was employed in the capacitance detection to restrain the noise interference.The capacitance analysis shows that 1 fF capacitance variation corresponds to 0.1 degree of the turn angle.The differential capacitance bridge and the charge integral amplifier were used as the front signal input interface.In the implementation of digital lock-in amplifier,a new routine which warranted the exactly matching of the reference phase to signal phase was proposed.The result of the experiment shows that digital lock-in amplifier can greatly eliminate the noise in the output signal.The non linearity of the turn angle output is 2.3% and the minimum resolution of turn angle is 0.04 degrees.The application of the software demodulation in the signal detection of micro-electro-mechanical-system(MEMS)device is a new attempt,and it shows the prospective for a high-performance application.展开更多
In this paper,a new direct optical triangulation(DOT) for measuring theout-of-plane displacement is given.In order to state its principle,DOT is used to measure a micro-displacement of a rigid body,and at the same tim...In this paper,a new direct optical triangulation(DOT) for measuring theout-of-plane displacement is given.In order to state its principle,DOT is used to measure a micro-displacement of a rigid body,and at the same time,the method of digital image processing is also given.展开更多
基金The National Natural Science Foundation ofChina(No.60402003)The National High Technology Research and Development Pro-gram of China(863Program)(No.2002AA745120)
文摘In the novel prototype of micro-gyroscope structure,the new configured capacitance sensing scheme for the micro gyroscope was analyzed and the virtual instrument based detection scheme was implemented.The digital lock-in amplifier was employed in the capacitance detection to restrain the noise interference.The capacitance analysis shows that 1 fF capacitance variation corresponds to 0.1 degree of the turn angle.The differential capacitance bridge and the charge integral amplifier were used as the front signal input interface.In the implementation of digital lock-in amplifier,a new routine which warranted the exactly matching of the reference phase to signal phase was proposed.The result of the experiment shows that digital lock-in amplifier can greatly eliminate the noise in the output signal.The non linearity of the turn angle output is 2.3% and the minimum resolution of turn angle is 0.04 degrees.The application of the software demodulation in the signal detection of micro-electro-mechanical-system(MEMS)device is a new attempt,and it shows the prospective for a high-performance application.
文摘In this paper,a new direct optical triangulation(DOT) for measuring theout-of-plane displacement is given.In order to state its principle,DOT is used to measure a micro-displacement of a rigid body,and at the same time,the method of digital image processing is also given.