期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
数字X线DR摄影技术在放射科中的应用探讨
1
作者 潘俊峰 《中文科技期刊数据库(文摘版)医药卫生》 2021年第10期229-230,共2页
分析数字X线DR摄影技术在放射科中应用。方法:分析目标为我科放射检查128例患者,分析时间设置为2020年2月-2021年4月,分析方法为随机数法,将128例患者分为对照组和观察组,分析两组检查患者分别在传统X线与数字X线DR技术下的效果。结果:... 分析数字X线DR摄影技术在放射科中应用。方法:分析目标为我科放射检查128例患者,分析时间设置为2020年2月-2021年4月,分析方法为随机数法,将128例患者分为对照组和观察组,分析两组检查患者分别在传统X线与数字X线DR技术下的效果。结果:观察组1级患者28例,对照组1级58例,观察组1级患者例数及占比明显更低;而观察组2级患者21例、3级15例明显比对照组2级(6例)、3级(0例)例数高,区间差异明显(P<0.05);观察组检查满意度优于对照组(P<0.05)。结论:数字X线DR摄影技术在放射科应用中图像质量更高、处理的效率更快,并且筛查疾病的准确率也明显提升,同时,在很大程度上提高了患者对医学检查的认可,增强满意度,对疾病的筛查具有显著的优势,因此,可广泛应用到放射科临床检查工作中。 展开更多
关键词 数学x线 DR摄影 放射科 应用
下载PDF
Crystallographic Parameters and Band Gap of CdSxSe1-x Mixed Crystals
2
作者 Abdullah A. Al-Bassam Usamh A. Elani 《Journal of Energy and Power Engineering》 2014年第4期770-774,共5页
Crystals of CdSxSe1-x alloys have been grown from the vapour phase. Some of the physical properties, such as lattice parameters, crystal structure and x-rays data of CdSxSe1-x alloys were determined using x-ray diffra... Crystals of CdSxSe1-x alloys have been grown from the vapour phase. Some of the physical properties, such as lattice parameters, crystal structure and x-rays data of CdSxSe1-x alloys were determined using x-ray diffractometry. X-ray diffractometry has shown that CdS-CdSe mixed crystals had the wurtzite structure for all compositions between CdS and CdSe. The lattice parameters (both a and c) were found to show a linear dependence with composition. The dependence of the lattice parameters of a and c on composition can be expressed as: a(x) = 4.165 + 0.16x; c(x) = 6.713 + 0.27x. The variation of band gap with composition was determined for these samples from optical absorption measurements, which showed that the band gap varied smoothly and monotonically, but not linearly over the composition range typical results were found between 2.42-1.74 eV at room temperature. 展开更多
关键词 Thin films mixed crystals lattice parameter SEMICONDUCTORS devices.
下载PDF
Radiobiological effect of abdominal X-ray hypo-fraction irradiation on Wistar rats liver
3
作者 Peng Qi Yongheng An +1 位作者 Hongsheng Yu Xinjia He 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第7期395-398,共4页
Objective: The aim of our study was to investigate the impact of abdominal hypo-fraction irradiation on liver damage in rats so as to provide a reference for its clinical application. Methods: A total of 100 Wistar ra... Objective: The aim of our study was to investigate the impact of abdominal hypo-fraction irradiation on liver damage in rats so as to provide a reference for its clinical application. Methods: A total of 100 Wistar rats were equally randomized to five groups as control, 4 Gy, 6 Gy, 8 Gy and 12 Gy group, and the corresponding fractionated doses were offered. Liver functions were examined at the 2nd, 4th, 6th, 8th and 10th week after irradiation. Morphological changes were observed by HE staining. Expressions of Bcl-2 and Bax were examined by immunohistochemical technique. Results: In all irradiation groups, hepatocellular swell, degeneration, necrosis and even hepatic fibrosis could be seen. The differences of the liver coefficient, Glutamyl pyruvic transaminase (GPT), Glutamyl oxaloacetic transaminase (GOT) were significant among the groups and different time points (F = 11.833-781.972, F = 20.857-264.692, P < 0.001). Expressions of Bcl-2 and Bax were significantly different between each group (F = 211.607, 116.577; P < 0. 001), and between each time point (F = 54.083, 68.749; P < 0. 001). Conclusion: Compare with conventional fraction, abdominal hypo-fraction irradiation may cause radiation damage to rat liver, being dose-and-time dependent. Up-regulation of activating apoptosis protein Bax and down-regulation of inhibiting apoptosis protein Bcl-2 may involve in the process. 展开更多
关键词 RADIOTHERAPY dose fractionation LIVER radiobiological effects apoptosis BCL-2/BAx
下载PDF
Void defect detection in BGA solder joints using mathematical morphology
4
作者 张俊生 王明泉 +2 位作者 王玉 王军 郭晋秦 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第2期199-204,共6页
Voids are one of the major defects in ball grid array (BGA) solder joints due to a large amount of outgassing flux that gets entrapped during reflow. X-ray nondestructive machines are used to make voids visible ... Voids are one of the major defects in ball grid array (BGA) solder joints due to a large amount of outgassing flux that gets entrapped during reflow. X-ray nondestructive machines are used to make voids visible as lighter areas inside the solder joints in X-ray images for detection However, it has always been difficult to analyze this problem automatically because of some challenges such as noise, inconsistent lighting and void-like artifacts. This study realized accurate extraction and automatic a-nalysis of void defects in solder joints by adopting a technical proposal, in which Otsu algorithm was used to segment solder balls and void defects were extracted through opening and closing operations and top-hat transformation in mathematical mor-phology. Experimental results show that the technical proposal mentioned here has good robustness and can be applied in the detection of voids in BGA solder joints. 展开更多
关键词 ball grid array (BGA) void defect x-RAY OTSU mathematical morphology
下载PDF
Hydration process of rice husk ash cement paste and its corrosion resistance of embedded steel bar 被引量:4
5
作者 WANG Hui ZHANG Ai-lian +7 位作者 ZHANG Lin-chun WANG Qian HAN Yan LIU Jun-zhe GAO Xiao-jian SHI Fei-ting LIN Xue-yan FENG Li-yu 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第11期3464-3476,共13页
Thermogravimetric analysis and electrical resistivity were used to determine the hydration process of cement paste with rice husk ash(RHA)(0−15%)and water-cement ratio of 0.4 in this work.X-ray diffraction(XRD)method ... Thermogravimetric analysis and electrical resistivity were used to determine the hydration process of cement paste with rice husk ash(RHA)(0−15%)and water-cement ratio of 0.4 in this work.X-ray diffraction(XRD)method and scanning electron microscopy(SEM)were used to survey crystal composition and microstructures of specimens cured for 3 h,1 d,7 d and 28 d.Finally,electrical parameters(electrical resistance and AC impedance spectroscopy)of steel bars reinforced cement paste were investigated to study the effect of RHA on the corrosion resistance.Results showed that RHA could affect the cement hydration by hydration promotion and pozzolanic effect.The evaluation function for electrical resistivity and curing ages fitted well with linear increasing function.The addition of RHA higher than 5%demonstrated a decreasing role in the electrical resistivity of cement paste at earlier curing ages(3−7 d).Meanwhile,when at later curing ages(7−28 d)the result was the opposite.Moreover,RHA demonstrated positive effects on corrosion resistance of steel bars in cement paste. 展开更多
关键词 rice husk ash thermogravimetric analysis electrical parameters x-ray diffraction corrosion resistance
下载PDF
Calculation of the coefficient and dynamics of water diffusion in graphite joints
6
作者 WANG Jun LIU Wen-bin 《Journal of Marine Science and Application》 2006年第2期65-70,共6页
The coefficient and dynamics of water diffusion in adhesive-graphite joints were calculated in-situ with energy dispersive X-ray (EDX) analysis, a method that is significantly simpler than elemental analysis. Water di... The coefficient and dynamics of water diffusion in adhesive-graphite joints were calculated in-situ with energy dispersive X-ray (EDX) analysis, a method that is significantly simpler than elemental analysis. Water diffusion coefficient and dynamics of adhesive-graphite joints treated by different surface treatment methods were also investigated. Calculation results indicated that the water diffusion rate in adhesive-graphite joints treated by sandpaper was higher than that treated by chemical oxidation or by silane couple agent. Also the durability of graphite joints treated by coupling agent is superior to that treated by chemical oxidation or sandpaper burnishing. 展开更多
关键词 adhesive-graphite joints diffusion coefficient diffusion dynamics energy dispersive x-ray (EDx
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部