The Saharan areas and in particular the isolated sites are characterized by low levels of population, in dispersed cores, which suffer from serious problems of water supply for consumption and the irrigation. The phot...The Saharan areas and in particular the isolated sites are characterized by low levels of population, in dispersed cores, which suffer from serious problems of water supply for consumption and the irrigation. The photovoltaic pumping systems (PV) are an ideal solution for these problems. Despite the presence of several photovoltaic pumping systems (PVPS) projects, data acquisition system is still missing in most cases. In this work, the authors will present the PVPS installed at the unit of research in renewable energies in Saharan medium (URERMS, Algeria). This system will enable us to better analyze the performances ofa photovoltaic pumping system in Saharan medium. The principal elements of the chain of the photovoltaic pumping system are: a photovoltaic generator, the power conditioning system, a motor-driven pump immersed group, an electric wiring, a hydraulic infrastructure which comprises a water tank.展开更多
To apply electrical stimulation to the specific phase position of electroencephalogram (EEG) waveform, a nervous electrical stimulation system was developed using general data acquisition card and LabVIEW virtual in...To apply electrical stimulation to the specific phase position of electroencephalogram (EEG) waveform, a nervous electrical stimulation system was developed using general data acquisition card and LabVIEW virtual instrument environment. The hippocampal field potential signal in the brain of rat was sampled using the acquisition card' s A/D channel, and the amplitude and cycle characteristics were analyzed and the wave peak or trough of the coming field potential ( 0 ) rhythm was predicted using LabVIEW program. Meanwhile, the needed stimulus signal was output at the specified phase position via the digital port or D/A channel of the acquisition card, so as to implement the nerve stimulation. The experimental result showed that the prediction accuracies of 0 -rhythm wave peak and trough were up to 92% and 86%, respectively. The electrical stimulation system can be applied to predicting a variety of nervous rhythm wave phases and other signal characteristics because of its universality and flexibility. Thus, a new loop control stimulation method is provided for the nerve electrophysiology study and the electrical stimulation treatment of brain diseases.展开更多
In order to solve the difficulty of reading inconvenience in the measurement process of digital track gauge, a kind of image data acquisition system with low cost and stable performance is designed. The system uses th...In order to solve the difficulty of reading inconvenience in the measurement process of digital track gauge, a kind of image data acquisition system with low cost and stable performance is designed. The system uses the Cortex-M4 as the core of the STM32F407ZGT6 as the control core, the use of OV2640 as an image sensor to collect images, and the collection of image files stored in the SD card for subsequent image processing to achieve the goal of rail adjustment to lay the foundation. The experimental results show that the image acquisition is stable and refiable and the collected images are clear and meet the design requirements.展开更多
文摘The Saharan areas and in particular the isolated sites are characterized by low levels of population, in dispersed cores, which suffer from serious problems of water supply for consumption and the irrigation. The photovoltaic pumping systems (PV) are an ideal solution for these problems. Despite the presence of several photovoltaic pumping systems (PVPS) projects, data acquisition system is still missing in most cases. In this work, the authors will present the PVPS installed at the unit of research in renewable energies in Saharan medium (URERMS, Algeria). This system will enable us to better analyze the performances ofa photovoltaic pumping system in Saharan medium. The principal elements of the chain of the photovoltaic pumping system are: a photovoltaic generator, the power conditioning system, a motor-driven pump immersed group, an electric wiring, a hydraulic infrastructure which comprises a water tank.
文摘To apply electrical stimulation to the specific phase position of electroencephalogram (EEG) waveform, a nervous electrical stimulation system was developed using general data acquisition card and LabVIEW virtual instrument environment. The hippocampal field potential signal in the brain of rat was sampled using the acquisition card' s A/D channel, and the amplitude and cycle characteristics were analyzed and the wave peak or trough of the coming field potential ( 0 ) rhythm was predicted using LabVIEW program. Meanwhile, the needed stimulus signal was output at the specified phase position via the digital port or D/A channel of the acquisition card, so as to implement the nerve stimulation. The experimental result showed that the prediction accuracies of 0 -rhythm wave peak and trough were up to 92% and 86%, respectively. The electrical stimulation system can be applied to predicting a variety of nervous rhythm wave phases and other signal characteristics because of its universality and flexibility. Thus, a new loop control stimulation method is provided for the nerve electrophysiology study and the electrical stimulation treatment of brain diseases.
文摘In order to solve the difficulty of reading inconvenience in the measurement process of digital track gauge, a kind of image data acquisition system with low cost and stable performance is designed. The system uses the Cortex-M4 as the core of the STM32F407ZGT6 as the control core, the use of OV2640 as an image sensor to collect images, and the collection of image files stored in the SD card for subsequent image processing to achieve the goal of rail adjustment to lay the foundation. The experimental results show that the image acquisition is stable and refiable and the collected images are clear and meet the design requirements.