The degradation characteristics of both wide and narrow devices under V _g= V _d/2 stress mode is investigated.The width-enhanced device degradation can be seen with devices narrowing.The main degradation mechanism is...The degradation characteristics of both wide and narrow devices under V _g= V _d/2 stress mode is investigated.The width-enhanced device degradation can be seen with devices narrowing.The main degradation mechanism is interface state generation for pMOSFETs with different channel width.The cause of the width-enhanced device degradation is attributed to the combination of width-enhanced threshold voltage and series resistance.展开更多
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele...The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter.展开更多
An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two...An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two-phase closed thermosyphon (TPCT). The performance of the ECT system was examined over a range of flow conditions.The experimental data were compared with the visual observations and existing correlations. Results indicated that the ECT system, with the linear back projection (LBP) algorithm, could be used to give an on-line qualitative image of the flow patterns. The Landweber iteration algorithm with optimal step length was implemented off-line to reconstruct high-resolution images. Then, the images were analyzed to obtain the film thickness of the annular flow. The experimental data compared well with the Nusselt's equation in low vapor velocity range, but showed an increasing deficiency with the increase of vapor velocity.展开更多
文摘The degradation characteristics of both wide and narrow devices under V _g= V _d/2 stress mode is investigated.The width-enhanced device degradation can be seen with devices narrowing.The main degradation mechanism is interface state generation for pMOSFETs with different channel width.The cause of the width-enhanced device degradation is attributed to the combination of width-enhanced threshold voltage and series resistance.
文摘The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter.
文摘An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two-phase closed thermosyphon (TPCT). The performance of the ECT system was examined over a range of flow conditions.The experimental data were compared with the visual observations and existing correlations. Results indicated that the ECT system, with the linear back projection (LBP) algorithm, could be used to give an on-line qualitative image of the flow patterns. The Landweber iteration algorithm with optimal step length was implemented off-line to reconstruct high-resolution images. Then, the images were analyzed to obtain the film thickness of the annular flow. The experimental data compared well with the Nusselt's equation in low vapor velocity range, but showed an increasing deficiency with the increase of vapor velocity.