This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of thi...This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.展开更多
In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature ...In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature of BD (bypass diodes) mounted on PV modules was measured for simple and practical fault detection. The temperature of the BD of Module 31 was higher than other modules and a large current passed through one of the BDs. Measuring BD temperatures is easier than other conventional methods of fault detection. From the results of the rise in BD temperature under dark conditions, the increase in temperature increased linearly with increasing current flow. There is a proportional relationship between heat generated and the increasing temperature of the terminal box. The experimental results about surface temperature of the junction box in actual system operation suggested that the electric current through a BD in a terminal box can be known by measuring the surface temperature of the terminal box for PV module fault detection without a system shutdown. Moreover, we tried to evaluate temperature distribution of a terminal box using heat conduction equations. The evaluated results agreed well with the measured results.展开更多
文摘This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.
文摘In recent years, PV (photovoltaic) systems have been installed rapidly around the world. However, there is often a delay in the practical application of fault detection in PV systems. In this study, the temperature of BD (bypass diodes) mounted on PV modules was measured for simple and practical fault detection. The temperature of the BD of Module 31 was higher than other modules and a large current passed through one of the BDs. Measuring BD temperatures is easier than other conventional methods of fault detection. From the results of the rise in BD temperature under dark conditions, the increase in temperature increased linearly with increasing current flow. There is a proportional relationship between heat generated and the increasing temperature of the terminal box. The experimental results about surface temperature of the junction box in actual system operation suggested that the electric current through a BD in a terminal box can be known by measuring the surface temperature of the terminal box for PV module fault detection without a system shutdown. Moreover, we tried to evaluate temperature distribution of a terminal box using heat conduction equations. The evaluated results agreed well with the measured results.