Based on the analysis of conditions for airflow reversal within a bypass branch, the airflow reversal phenomena were successfully simulated in the laboratory experiments. Data obtained indicate that airflow reversal w...Based on the analysis of conditions for airflow reversal within a bypass branch, the airflow reversal phenomena were successfully simulated in the laboratory experiments. Data obtained indicate that airflow reversal within a bypass branch is mainly caused by fire pressure yielded in the combustion branch. In addition, the maximum reversal quantity of airflow occurs in step with the highest temperature of fire, the highest concentration of CO 2 and the lowest concentration of O 2. Moreover, the time that fire size reaches the maximum value corresponds to the time airflow reversal in the bypass branch is most possible. The results are of great significance for guiding rescue work to avoid airflow reversal.展开更多
基金National Natural Science Foundation of China( 5 9876 0 45 )
文摘Based on the analysis of conditions for airflow reversal within a bypass branch, the airflow reversal phenomena were successfully simulated in the laboratory experiments. Data obtained indicate that airflow reversal within a bypass branch is mainly caused by fire pressure yielded in the combustion branch. In addition, the maximum reversal quantity of airflow occurs in step with the highest temperature of fire, the highest concentration of CO 2 and the lowest concentration of O 2. Moreover, the time that fire size reaches the maximum value corresponds to the time airflow reversal in the bypass branch is most possible. The results are of great significance for guiding rescue work to avoid airflow reversal.