The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful...The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful not only for the reduction of the interaction tone noise but also for the improvement of the pressure recovery characteristics within the diffuser passage. By using tapered diffuser vanes, the interaction area between the impeller-discharge flow and diffuser vanes becomes small, and then the noise level of the discrete tone can be reduced remarkably as a result. Furthermore, by utilizing the visualization technique of vortical structures based on the CFD results, the scale of vortex shedding leaving from the leading edge of the diffuser vanes is found to be contracted and a tendency for the turbulence level to decrease is observed. This may be the cause of the attenuation of broadband noise components. The secondary flow, which is considered to be an obstruction of diffuser pressure recovery, can also be suppressed by the tapered diffuser vanes, and the pressure decrease observed in the throat part of the diffuser passage is further reducible.展开更多
This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predi...This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predicted by an ARI standard 540 map-based compressor model and verified by a semi-open drying heat pump system constructed for this purpose. A comparison of the experimental data with the predicted data proved that the new scroll compressor used in the drying heat pump works well, can supply a wide range of condensing temperatures (30--80℃) (without auxiliary heating), and has a minimum coeffi- cient of performance (COP) above 2.0, even in the worst condition.展开更多
文摘The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful not only for the reduction of the interaction tone noise but also for the improvement of the pressure recovery characteristics within the diffuser passage. By using tapered diffuser vanes, the interaction area between the impeller-discharge flow and diffuser vanes becomes small, and then the noise level of the discrete tone can be reduced remarkably as a result. Furthermore, by utilizing the visualization technique of vortical structures based on the CFD results, the scale of vortex shedding leaving from the leading edge of the diffuser vanes is found to be contracted and a tendency for the turbulence level to decrease is observed. This may be the cause of the attenuation of broadband noise components. The secondary flow, which is considered to be an obstruction of diffuser pressure recovery, can also be suppressed by the tapered diffuser vanes, and the pressure decrease observed in the throat part of the diffuser passage is further reducible.
基金supported by the National High Technology Research and Development Program of China(Grant No.2012AA10A510)
文摘This study presents the performance of a new single-stage scroll compressor used for the heat pump drying of thermally sensitive materials over a wide temperature range. The performance of the new compressor was predicted by an ARI standard 540 map-based compressor model and verified by a semi-open drying heat pump system constructed for this purpose. A comparison of the experimental data with the predicted data proved that the new scroll compressor used in the drying heat pump works well, can supply a wide range of condensing temperatures (30--80℃) (without auxiliary heating), and has a minimum coeffi- cient of performance (COP) above 2.0, even in the worst condition.