A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vor...A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger. The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted. The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each comer of a square. The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software. The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed. The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle; meanwhile, higher flow resistance is also accompanied. It is believe that the strip-coil- baffled heat exchanger should have promising applications in many industry fields.展开更多
The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful...The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful not only for the reduction of the interaction tone noise but also for the improvement of the pressure recovery characteristics within the diffuser passage. By using tapered diffuser vanes, the interaction area between the impeller-discharge flow and diffuser vanes becomes small, and then the noise level of the discrete tone can be reduced remarkably as a result. Furthermore, by utilizing the visualization technique of vortical structures based on the CFD results, the scale of vortex shedding leaving from the leading edge of the diffuser vanes is found to be contracted and a tendency for the turbulence level to decrease is observed. This may be the cause of the attenuation of broadband noise components. The secondary flow, which is considered to be an obstruction of diffuser pressure recovery, can also be suppressed by the tapered diffuser vanes, and the pressure decrease observed in the throat part of the diffuser passage is further reducible.展开更多
基金The National Basic Research Program of China(973Program) (NoG2000026303)the National Natural Science Foun-dation of China (No50176008)
文摘A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger. The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted. The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each comer of a square. The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software. The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed. The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle; meanwhile, higher flow resistance is also accompanied. It is believe that the strip-coil- baffled heat exchanger should have promising applications in many industry fields.
文摘The effects of a three-dimensional tapered diffuser vane on the flow field and noise radiated from a centrifugal compressor are investigated by both CFD analyses and experiments. Tapered diffuser vanes are very useful not only for the reduction of the interaction tone noise but also for the improvement of the pressure recovery characteristics within the diffuser passage. By using tapered diffuser vanes, the interaction area between the impeller-discharge flow and diffuser vanes becomes small, and then the noise level of the discrete tone can be reduced remarkably as a result. Furthermore, by utilizing the visualization technique of vortical structures based on the CFD results, the scale of vortex shedding leaving from the leading edge of the diffuser vanes is found to be contracted and a tendency for the turbulence level to decrease is observed. This may be the cause of the attenuation of broadband noise components. The secondary flow, which is considered to be an obstruction of diffuser pressure recovery, can also be suppressed by the tapered diffuser vanes, and the pressure decrease observed in the throat part of the diffuser passage is further reducible.