期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
旋管器在长距离大口径渗滤液管道疏通清洗中的应用
1
作者 刘世超 杨建 《清洗世界》 CAS 2024年第2期13-15,共3页
渗滤液管道结垢问题广泛存在于填埋场的渗滤液导排系统中。渗滤液管道长期运行,管道内结垢量大且可能存在管道局部形变,为疏通清洗工作造成很大困难。针对以上问题,本文采用旋管器辅助的高压水射流清洗技术成功的疏通了规格为DN400且存... 渗滤液管道结垢问题广泛存在于填埋场的渗滤液导排系统中。渗滤液管道长期运行,管道内结垢量大且可能存在管道局部形变,为疏通清洗工作造成很大困难。针对以上问题,本文采用旋管器辅助的高压水射流清洗技术成功的疏通了规格为DN400且存在局部形变的渗滤液主管管道。在空气中,高压水射流压力为65 MPa时可以有效的击碎渗滤液垢;在渗滤液浸没条件下,高压水射流压力升值为75 MPa后成功疏通位于水面以下的堵塞区域;同时,验证了推进器在长距离管道清洗过程中对中喷头和高压管前进的速度提升的有效性。为同类型管道的疏通清洗工作提供了重要借鉴。 展开更多
关键词 高压水 射流清洗技术 旋管器 渗滤液管道 疏通
下载PDF
Numerical simulation of heat transfer enhancement by strip-coil-baffles in tube-bundle for a tube-shell heat exchanger
2
作者 陈亚平 梅娜 施明恒 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期81-85,共5页
A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vor... A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger. The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted. The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each comer of a square. The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software. The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed. The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle; meanwhile, higher flow resistance is also accompanied. It is believe that the strip-coil- baffled heat exchanger should have promising applications in many industry fields. 展开更多
关键词 heat transfer enhancement strip-coil-baffle tube-shell heat exchanger vortex flow numerical simulation
下载PDF
Enhancement patterns of pancreatic adenocarcinoma on conventional dynamic multi-detector row CT:Correlation with angiogenesis and fibrosis 被引量:15
3
作者 Yuki Hattori Toshifumi Gabata +5 位作者 Osamu Matsui Kentaro Mochizuki Hirohisa Kitagawa Masato Kayahara Tetsuo Ohta Yasuni Nakanuma 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第25期3114-3121,共8页
AIM:To evaluate retrospectively the correlation between enhancement patterns on dynamic computed tomography (CT) and angiogenesis and fibrosis in pancreatic adenocarcinoma.METHODS: Twenty-three patients with pancreati... AIM:To evaluate retrospectively the correlation between enhancement patterns on dynamic computed tomography (CT) and angiogenesis and fibrosis in pancreatic adenocarcinoma.METHODS: Twenty-three patients with pancreatic adenocarcinoma underwent dynamic CT and tumor resection. In addition to the absolute and relative enhanced value that was calculated by subtracting the attenuation value on pre-contrast from those on contrast-enhanced CT in each phase, we defined one parameter, "tumor-aorta enhancement ratio", which was calculated by dividing enhancement of pancreatic cancer by enhancement of abdominal aorta in each phase. These enhancement patterns were correlated with the level of vascular endothelial growth factor (VEGF), microvessel density (MVD), and extent of fibrosis.RESULTS: The absolute enhanced value in the arterial phase correlated with the level of VEGF and MVD (P=0.047, P=0.001). The relative enhanced value in arterial phase and tumor-aorta enhancement ratio (arterial) correlated with MVD (P=0.003, P=0.022). Tumor-aorta enhancement ratio (arterial) correlated negatively with the extent of fibrosis (P=0.004). The tumors with greater MVD and higher expression of VEGF tended to show high enhancement in the arterial dominant phase. On the other hand, the tumors with a larger amount of fibrosis showed a negative correlation with the grade of enhancement during the arterial phase.CONCLUSION: Enhancement patterns on dynamic CT correlated with angiogenesis and may be modified by the extent of fibrosis. 展开更多
关键词 Computed tomography Contrast media Pancreatic cancer ANGIOGENESIS
下载PDF
An advanced turbulator with blades and semi-conical section for heat transfer improvement in a helical double tube heat exchanger
4
作者 Seyed Hossein HASHEMI KAROUEI Seyed Soheil MOUSAVI AJAROSTAGHI +1 位作者 Saman RASHIDI Elham HOSSEINIRAD 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3491-3506,共16页
In present work,a helical double tube heat exchanger is proposed in which an advanced turbulator with blades,semi-conical part,and two holes is inserted in inner section.Two geometrical parameters,including angle of t... In present work,a helical double tube heat exchanger is proposed in which an advanced turbulator with blades,semi-conical part,and two holes is inserted in inner section.Two geometrical parameters,including angle of turbulator’s blades(θ) and number of turbulator’s blades(N),are considered.Results indicated that firstly,the best thermal stratification is achieved at θ=180°.Furthermore,at the lowest studied mass flow rate(m = 8 × 10^(-3) kg/s),heat transfer coefficient of turbulator with blade angle of 180° is 130.77%,25%,and 36.36% higher than cases including without turbulator,with turbulator with blade angle of θ =240°,and θ =360°,respectively.Moreover,case with N=12 showed the highest overall performance.At the highest studied mass flow rate(m = 5.842 × 10^(-2) kg/s),heat transfer coefficient for case with N=12 is up to 54.76%,27.45%,and 6.56% higher than cases including without turbulator,with turbulator with N=6,and with turbulator with N=9,respectively. 展开更多
关键词 helical double tube heat exchanger TURBULATOR BLADE thermal performance swirl flows
下载PDF
Experimental Verification to Estimate Ground Thermal Conductivity Using Spiral Coil Type Ground Heat Exchangers
5
作者 Seok Yoon Min Jun Kim Gyu Hyun Go Seung Rae Lee 《Journal of Civil Engineering and Architecture》 2014年第4期425-429,共5页
This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of s... This paper presents an experimental study on the evaluation of thermal response of a spiral coil type GHE (ground heat exchanger). This GHE was installed on partially saturated landfill ground that was composed of silt and clay in the runway area of Incheon International airport. TRT (thermal response test) was conducted for more than 65 hours under continuous operation conditions. Ground thermal conductivity was derived based on line source theory, which has usually been found to be appropriate for line type GHEs such as U, W and 2U types. A reasonable method to derive ground thermal conductivity using the infinite line source theory for a spiral coil type GHE was introduced. Ground thermal conductivity from the TRT using spiral coil type GHE was compared with those from the analytical equivalent model of ground thermal conductivity. 展开更多
关键词 Ground thermal conductivity ground heat exchanger thermal response test spiral coil.
下载PDF
Numerical simulation of the effect of upstream swirling flow on swirl meter performance 被引量:4
6
作者 CHEN Desheng CUI Baoling ZHU Zuchao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2018年第2期117-124,共8页
Flow measurement is important in the fluid process and transmission system. For the need of accuracy measure- ment of fluid, stable flow is acquired. However, the elbows and devices as valves and rotary machines may p... Flow measurement is important in the fluid process and transmission system. For the need of accuracy measure- ment of fluid, stable flow is acquired. However, the elbows and devices as valves and rotary machines may pro- duce swirling flow in the natural gas pipeline networks system and many other industry fields. In order to reveal the influence of upstream swirling flow on internal flow fields and the metrological characteristics, numerical si- mulations are carried out on the swirl meter. Using RNG k-e turbulent model and SIMPLE algorithm, the flow field is numerically simulated under swirling flows generated from co-swirl and counter-swirl flow. Simulation results show fluctuation is enhanced or weakened depending on the rotating direction of swirling flow. A coun- ter-swift flow increases the entropy production rate at the inlet and outlet of the swirler, the junction region between throat and divergent section, and then the pressure loss is increased. The vortex precession dominates the static pressure distributions on the solid walls and in the channel, especially at the end region of the throat. 展开更多
关键词 Swirl meter Numerical simulation swirling flow vortex precession
原文传递
Van der Waals contact between 2D magnetic VSe_(2)and transition metals and demonstration of high-performance spin-field-effect transistors 被引量:3
7
作者 Jiaduo Zhu Xing Chen +4 位作者 Wei Shang Jing Ning Dong Wang Jincheng Zhang Yue Hao 《Science China Materials》 SCIE EI CAS CSCD 2021年第11期2786-2794,共9页
This study used density functional theory and the quantum transport method to investigate the interfacial coupling and spin transport of transition metals(TMs)with a Fe,Co,and Ni/2H-VSe_(2)hybrid nanostructure.Because... This study used density functional theory and the quantum transport method to investigate the interfacial coupling and spin transport of transition metals(TMs)with a Fe,Co,and Ni/2H-VSe_(2)hybrid nanostructure.Because the indirect coupling of TM-Se-V led to an obvious reduction of the magnetic moment and the disappearance of the half-metal characteristics of 2H-VSe_(2),the expected spin-filtering effect of individual TMs and 2H-VSe_(2)deteriorated at the contact region.Nevertheless,all the TM/2H-VSe_(2)-based dual-probe devices exhibited an interesting bias-dependent spin-injection efficiency with a maximum output spin-polarized current of 666 mA mm-1 in Co/2H-VSe_(2).The proposed TM/2H-VSe_(2)-based spin-field-effect transistor demonstrated outstanding performance.The Ni/2H-VSe_(2)-based transistor achieved a maximum output spin-polarized current of 3117 m A mm-1 and demonstrated a good switching characteristic of 106 mV dec-1.Importantly,all transistors achieved a widely tunable scale of spin-extraction efficiency ranging consistently between 96%and-92%with gate bias.These results indicate a promising candidate for use in high-performance spintronic devices. 展开更多
关键词 VSe2 CONTACT DFT spin-FET
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部