Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylid...Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylidene fluoride (PVDF, 0.1 μm), cellulose acetate (CA, 0.22 μm), sulfonated polyethersulfone (SPES, 0.22 μm) and polyamide (PA, 0.45 μm), respectively, were used in filtration experiments. The dependence of the filtrate mass of the cross-flow MF on time was measured on-line. The experimental results showed that the effect of the cross-flow on high viscosity medium was more significant than that on the low viscosity one.展开更多
Rotating systems have many applications in wide-ranging industrial contexts. The breakdown of this equipment results in economic wastes and leads to dangerous situations. To avoid such problems is very important, and ...Rotating systems have many applications in wide-ranging industrial contexts. The breakdown of this equipment results in economic wastes and leads to dangerous situations. To avoid such problems is very important, and it can be done through tools that inform about the existence of faults, as well as, about their progress in time. A review of the modeling process used for rotor-support-structure shows that the finite element method is the maj or method employed. In this paper, with the aid of well defined theoretical models, obtained using the finite element technique, and the state observer method for the identification and location of faults, it is possible to monitor the parameters of a rotor-support-structure system, including the foundation effects. In order to improve safety, these parameters must be supervised in case of the occurrence of failures or faults. The state observers are designed using Linear Matrix Inequalities (LMIs). Finally, experimental results (using for this a rotation system in the mechanical vibrations laboratory at Ilha Solteira's Mechanical Engineering Department) demonstrate the effectiveness of the methodology developed.展开更多
Recent experiments open up the possibility to investigate oblate rotation-aligned states and prolate high-K isomers in neutron-rich tungsten isotopes.In the present work,we perform the projected-shell-model calculatio...Recent experiments open up the possibility to investigate oblate rotation-aligned states and prolate high-K isomers in neutron-rich tungsten isotopes.In the present work,we perform the projected-shell-model calculations for A ~ 190 tungsten nuclei.The 190 W results are compared with experimental data.The observed 8 + isomer is assigned as a two-quasiproton K π = 8 + configuration.Low-lying high-K four-quasiparticle states are predicted.Of particular interest is the prediction of the K π = 20 + state in 190,192 W,which may form a long-lived spin trap.In competition with the prolate high-K states,rotational alignment leads to near-yrast collective oblate rotation.展开更多
A valveless piezoelectric pump with rotatable unsymmetrical slopes is developed in this research.It has the following features:The pump integrates driving and transporting,and it can mix different fluids while transpo...A valveless piezoelectric pump with rotatable unsymmetrical slopes is developed in this research.It has the following features:The pump integrates driving and transporting,and it can mix different fluids while transporting them.In this paper,firstly,the design of the valveless piezoelectric pump with rotatable unsymmetrical slopes was proposed,and the single-direction flow principle was explained.Then,the fluid mechanics model of the valveless piezoelectric pump with rotatable unsymmetrical slopes was established.Meanwhile,the numerical simulation of the pump was performed.Finally,the experiments on relationship between the rotation angles of the slope and the flow rates were conducted.The experimental results showed that the maximum flow was 32.32 mL min 1.The maximum relative error between the theoretical results and the experimental ones was 14.59%.For the relationship between rotation angles and flow ratio of two inlets,the relative error between the experimental and theoretical maxima was 3.75%.Thus,the experiments proved the feasibility of the pump design and verified the theory.展开更多
基金Supported by the State Key Development Program for Basic Research of China(2003CB615705)
文摘Experimental investigation of the microfiltration (MF) using a revolving cross-flow membrane filter was performed under the condition of constant pressure difference, and different flat membranes made of polyvinylidene fluoride (PVDF, 0.1 μm), cellulose acetate (CA, 0.22 μm), sulfonated polyethersulfone (SPES, 0.22 μm) and polyamide (PA, 0.45 μm), respectively, were used in filtration experiments. The dependence of the filtrate mass of the cross-flow MF on time was measured on-line. The experimental results showed that the effect of the cross-flow on high viscosity medium was more significant than that on the low viscosity one.
文摘Rotating systems have many applications in wide-ranging industrial contexts. The breakdown of this equipment results in economic wastes and leads to dangerous situations. To avoid such problems is very important, and it can be done through tools that inform about the existence of faults, as well as, about their progress in time. A review of the modeling process used for rotor-support-structure shows that the finite element method is the maj or method employed. In this paper, with the aid of well defined theoretical models, obtained using the finite element technique, and the state observer method for the identification and location of faults, it is possible to monitor the parameters of a rotor-support-structure system, including the foundation effects. In order to improve safety, these parameters must be supervised in case of the occurrence of failures or faults. The state observers are designed using Linear Matrix Inequalities (LMIs). Finally, experimental results (using for this a rotation system in the mechanical vibrations laboratory at Ilha Solteira's Mechanical Engineering Department) demonstrate the effectiveness of the methodology developed.
基金supported by the National Natural Science Foundation of China (Grant No. 10975006)
文摘Recent experiments open up the possibility to investigate oblate rotation-aligned states and prolate high-K isomers in neutron-rich tungsten isotopes.In the present work,we perform the projected-shell-model calculations for A ~ 190 tungsten nuclei.The 190 W results are compared with experimental data.The observed 8 + isomer is assigned as a two-quasiproton K π = 8 + configuration.Low-lying high-K four-quasiparticle states are predicted.Of particular interest is the prediction of the K π = 20 + state in 190,192 W,which may form a long-lived spin trap.In competition with the prolate high-K states,rotational alignment leads to near-yrast collective oblate rotation.
基金supported by the National Natural Science Foundation of China (Grant Nos. 50775109 and 51075201)the Important Projects of National Science Foundation of China (Grant No. 50735002)Open Fund of State Key Lab of Digital Manufacturing Equipment and Technology (Grant No. DMETKF2009002)
文摘A valveless piezoelectric pump with rotatable unsymmetrical slopes is developed in this research.It has the following features:The pump integrates driving and transporting,and it can mix different fluids while transporting them.In this paper,firstly,the design of the valveless piezoelectric pump with rotatable unsymmetrical slopes was proposed,and the single-direction flow principle was explained.Then,the fluid mechanics model of the valveless piezoelectric pump with rotatable unsymmetrical slopes was established.Meanwhile,the numerical simulation of the pump was performed.Finally,the experiments on relationship between the rotation angles of the slope and the flow rates were conducted.The experimental results showed that the maximum flow was 32.32 mL min 1.The maximum relative error between the theoretical results and the experimental ones was 14.59%.For the relationship between rotation angles and flow ratio of two inlets,the relative error between the experimental and theoretical maxima was 3.75%.Thus,the experiments proved the feasibility of the pump design and verified the theory.