In the study and implementation of a programmable RS codec module in satellite communication modem, FPGA is used as the kernel in the implementation, while some ASICs are used as necessary assistant measures. The modu...In the study and implementation of a programmable RS codec module in satellite communication modem, FPGA is used as the kernel in the implementation, while some ASICs are used as necessary assistant measures. The module includes the RS codec unit, the interleaver and deinterleaver unit, the scrambler and descrambler unit and the frame synchronization unit. The module is realized successfully and it can be programmed on-line to meet the requirements of IESS 308/309/310 including many specifications about different service types and data rates. With the implementation combining FPGA with ASICs, size of the circuit is much reduced, its flexibility dramatically increased, and its stability further strengthened. Furthermore, the module is based on the software radio concept and can be easily integrated into the whole satellite communication modem.展开更多
With a live wire, line impedance could be measured by means of only passive elements such as inductors or resistors, whose techniques are well known. However, as the voltage and current used for the measurement are in...With a live wire, line impedance could be measured by means of only passive elements such as inductors or resistors, whose techniques are well known. However, as the voltage and current used for the measurement are increased, the size of the inductor or resistor being used also needs to be increased, so it would be virtually impossible to make an accurate measurement. Because of this, the authors have developed a novel measurement method for line impedance using LC resonance, which the authors describe first place. In the second place, the authors propose another line impedance. The novel method is that the rectangular wave with minimum voltage is injected into the distribution line system. By means of this method, the line capacitance and the line inductance can be measured. These proposals are confirmed by the simulation or experiment. Finally, the frequency response analysis method is to be examined, whose mechanism and results are to be presented and discussed.展开更多
Baseband ASIP designs for handsets are discussed based on the author's R&D backgrounds. Algorithms for 4G, 3G, and WLAN are analyzed and selected for implementation based on the trade off of cost and performan...Baseband ASIP designs for handsets are discussed based on the author's R&D backgrounds. Algorithms for 4G, 3G, and WLAN are analyzed and selected for implementation based on the trade off of cost and performance with power consumption in mind. A SDR ASIP baseband system architecture is proposed for 4G and 3G mobile handsets. Function partitions for heterogeneous symbol processors are introduced to get higher performance over cost. Three structures for DFE, FFE, and Matrix symbol ASIP are proposed. The concept of bit parallel processor is introduced. Challenges of baseband processors for UDN of 5G were briefly introduced. Conclusions on ASIP architecture and system design are given for different baseband processors on different products.展开更多
Due to rapidly development of high power semiconductor devices with fast control features have made possible to control the power flow more efficiently and effectively. The Flexible AC Transmission Systems (FACTS) i...Due to rapidly development of high power semiconductor devices with fast control features have made possible to control the power flow more efficiently and effectively. The Flexible AC Transmission Systems (FACTS) in this category introduces several innovative operating control devices. One of the recent devices is Advanced Unified Power Flow Controller (AUPFC) or multi-converter UPFC, which can control bus voltage and real and reactive power flows of more than one line or even a sub-network. This paper presents performance analysis of AUPFC based on d-q axis model theory. Based on the analysis, a new fuzzy logic rules based control algorithm has been developed in this paper which improves the system performance. The control rules are structured depending upon the relationship between series inserted voltages in multi-line and the desired changes of real and reactive power flows in the control network. The impacts of different controllers along with parameters of series connected transformers and transmission lines have been investigated through developed control block models in SIMULINK. The effectiveness of the proposed scheme is demonstrated by a case study.展开更多
文摘In the study and implementation of a programmable RS codec module in satellite communication modem, FPGA is used as the kernel in the implementation, while some ASICs are used as necessary assistant measures. The module includes the RS codec unit, the interleaver and deinterleaver unit, the scrambler and descrambler unit and the frame synchronization unit. The module is realized successfully and it can be programmed on-line to meet the requirements of IESS 308/309/310 including many specifications about different service types and data rates. With the implementation combining FPGA with ASICs, size of the circuit is much reduced, its flexibility dramatically increased, and its stability further strengthened. Furthermore, the module is based on the software radio concept and can be easily integrated into the whole satellite communication modem.
文摘With a live wire, line impedance could be measured by means of only passive elements such as inductors or resistors, whose techniques are well known. However, as the voltage and current used for the measurement are increased, the size of the inductor or resistor being used also needs to be increased, so it would be virtually impossible to make an accurate measurement. Because of this, the authors have developed a novel measurement method for line impedance using LC resonance, which the authors describe first place. In the second place, the authors propose another line impedance. The novel method is that the rectangular wave with minimum voltage is injected into the distribution line system. By means of this method, the line capacitance and the line inductance can be measured. These proposals are confirmed by the simulation or experiment. Finally, the frequency response analysis method is to be examined, whose mechanism and results are to be presented and discussed.
基金supported by the National HighTech Research and Development Program of China (863 Program) 2014AA01A705.
文摘Baseband ASIP designs for handsets are discussed based on the author's R&D backgrounds. Algorithms for 4G, 3G, and WLAN are analyzed and selected for implementation based on the trade off of cost and performance with power consumption in mind. A SDR ASIP baseband system architecture is proposed for 4G and 3G mobile handsets. Function partitions for heterogeneous symbol processors are introduced to get higher performance over cost. Three structures for DFE, FFE, and Matrix symbol ASIP are proposed. The concept of bit parallel processor is introduced. Challenges of baseband processors for UDN of 5G were briefly introduced. Conclusions on ASIP architecture and system design are given for different baseband processors on different products.
文摘Due to rapidly development of high power semiconductor devices with fast control features have made possible to control the power flow more efficiently and effectively. The Flexible AC Transmission Systems (FACTS) in this category introduces several innovative operating control devices. One of the recent devices is Advanced Unified Power Flow Controller (AUPFC) or multi-converter UPFC, which can control bus voltage and real and reactive power flows of more than one line or even a sub-network. This paper presents performance analysis of AUPFC based on d-q axis model theory. Based on the analysis, a new fuzzy logic rules based control algorithm has been developed in this paper which improves the system performance. The control rules are structured depending upon the relationship between series inserted voltages in multi-line and the desired changes of real and reactive power flows in the control network. The impacts of different controllers along with parameters of series connected transformers and transmission lines have been investigated through developed control block models in SIMULINK. The effectiveness of the proposed scheme is demonstrated by a case study.