A fault injection model-oriented testing strategy was proposed for detecting component vulnerabilities.A fault injection model was defined,and the faults were injected into the tested component based on the fault inje...A fault injection model-oriented testing strategy was proposed for detecting component vulnerabilities.A fault injection model was defined,and the faults were injected into the tested component based on the fault injection model to trigger security exceptions.The testing process could be recorded by the monitoring mechanism of the strategy,and the monitoring information was written into the security log.The component vulnerabilities could be detected by the detecting algorithm through analyzing the security log.Lastly,some experiments were done in an integration testing platform to verify the applicability of the strategy.The experimental results show that the strategy is effective and operable.The detecting rate is more than 90%for vulnerability components.展开更多
Lack of up-to-date information on efficient operation and maintenance of EPDS (electric power distribution systems), Nigeria is addressed by designing and implementing an indigenous real-time monitoring and diagnosi...Lack of up-to-date information on efficient operation and maintenance of EPDS (electric power distribution systems), Nigeria is addressed by designing and implementing an indigenous real-time monitoring and diagnosis system. The system encompasses the development of software driven hardware positioned at the remotely located sub-stations at the low voltage level to keep track of the network in real-time. The detection of faults exploits threshold passing algorithm through continuous monitoring of the network power quality. Communication between the RTU (remote terminal unit) and the DCC (distribution control center) which is based on GSM is initiated by disturbance. The DCC performs fault evaluation processing using the received data and predetermined faults signatures to determine the nature of disturbance and presents the result in graphic user interface environment. A fault reporting time of 2 s was achieved. The developed system exhibits a high degree of accuracy and manifests no spurious reports during testing. The resultant system limits the effects of interruption and increases power availability by reducing the down time. The system strengthens engineering and management capabilities required to enhance reliability by providing information about the network health status.展开更多
基金Project(513150601)supported by the National Pre-Research Project Foundation of China
文摘A fault injection model-oriented testing strategy was proposed for detecting component vulnerabilities.A fault injection model was defined,and the faults were injected into the tested component based on the fault injection model to trigger security exceptions.The testing process could be recorded by the monitoring mechanism of the strategy,and the monitoring information was written into the security log.The component vulnerabilities could be detected by the detecting algorithm through analyzing the security log.Lastly,some experiments were done in an integration testing platform to verify the applicability of the strategy.The experimental results show that the strategy is effective and operable.The detecting rate is more than 90%for vulnerability components.
文摘Lack of up-to-date information on efficient operation and maintenance of EPDS (electric power distribution systems), Nigeria is addressed by designing and implementing an indigenous real-time monitoring and diagnosis system. The system encompasses the development of software driven hardware positioned at the remotely located sub-stations at the low voltage level to keep track of the network in real-time. The detection of faults exploits threshold passing algorithm through continuous monitoring of the network power quality. Communication between the RTU (remote terminal unit) and the DCC (distribution control center) which is based on GSM is initiated by disturbance. The DCC performs fault evaluation processing using the received data and predetermined faults signatures to determine the nature of disturbance and presents the result in graphic user interface environment. A fault reporting time of 2 s was achieved. The developed system exhibits a high degree of accuracy and manifests no spurious reports during testing. The resultant system limits the effects of interruption and increases power availability by reducing the down time. The system strengthens engineering and management capabilities required to enhance reliability by providing information about the network health status.