The area and elevation of the Tibetan Plateau over time has directly affected Asia’s topography,the characteristics of the Asian monsoon,and modified global climate—but in ways that are poorly understood.Charting th...The area and elevation of the Tibetan Plateau over time has directly affected Asia’s topography,the characteristics of the Asian monsoon,and modified global climate—but in ways that are poorly understood.Charting the uplift history is crucial for understanding the mechanisms that link elevation and climate irrespective of time and place.While some palaeoelevation data are available for southern and central Tibet,clues to the uplift history of northern Tibet remain sparse and largely circumstantial.Lately,展开更多
A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need f...A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need for heating and has fixed internal heat gains as intended for compliance assessment. With the calculator, the effect of any parameter implemented can be immediately seen on delivered and primary energy. Because of simple equations, it is suitable for implementation into CAD (computer aided design) design tools including basic BIM (building information modeling) data. Results showed that the accuracy of the correlation for the cases with practical relevance was not worse than 14% of the energy need of space heating. This applies for passive house insulation level; for less insulated building envelopes, the deviations were smaller. This 14% equals to only 3 kWh/(m2.a), i.e., the percentage difference in the total delivered and primary energy was much lower because of other components in the energy balance. The deviations determined were implemented in the calculator as safety margin. Results prove that simple energy performance assessment based on specific heat loss coefficient is well justified for early stage energy analyses as well as for compliance assessment implemented in Estonian regulation.展开更多
Ovarian cancer is one of the most deadly female genital malignant tumors in many regions while an effective early screening strategy can save numerous lives.CA125 and HE4 are tumor markers validated efficacious as wel...Ovarian cancer is one of the most deadly female genital malignant tumors in many regions while an effective early screening strategy can save numerous lives.CA125 and HE4 are tumor markers validated efficacious as well as most commonly used in recent screening research of ovarian cancer.In this paper,the authors construct a change-point and mixture model on the basis of longitudinal CA125 and HE4 levels and estimated parameters using maximum likelihood method with the preclinical duration assumed right-censored,which is more adaptive and yields comparable results in comparison to the Bayesian approach raised by Skates.Consistency of estimators is proved.The authors also run a 5-year simulation of sequential screening by calculating the risk of cancer and hypothesis testing the true incidence time respectively.Results show that diagnosis based on hypothesis test performs better in early detection.展开更多
文摘The area and elevation of the Tibetan Plateau over time has directly affected Asia’s topography,the characteristics of the Asian monsoon,and modified global climate—but in ways that are poorly understood.Charting the uplift history is crucial for understanding the mechanisms that link elevation and climate irrespective of time and place.While some palaeoelevation data are available for southern and central Tibet,clues to the uplift history of northern Tibet remain sparse and largely circumstantial.Lately,
文摘A simple calculator for early stage energy performance assessment in residential buildings was developed and partially validated in this study. The calculator is based on the correlation of heat loss and energy need for heating and has fixed internal heat gains as intended for compliance assessment. With the calculator, the effect of any parameter implemented can be immediately seen on delivered and primary energy. Because of simple equations, it is suitable for implementation into CAD (computer aided design) design tools including basic BIM (building information modeling) data. Results showed that the accuracy of the correlation for the cases with practical relevance was not worse than 14% of the energy need of space heating. This applies for passive house insulation level; for less insulated building envelopes, the deviations were smaller. This 14% equals to only 3 kWh/(m2.a), i.e., the percentage difference in the total delivered and primary energy was much lower because of other components in the energy balance. The deviations determined were implemented in the calculator as safety margin. Results prove that simple energy performance assessment based on specific heat loss coefficient is well justified for early stage energy analyses as well as for compliance assessment implemented in Estonian regulation.
基金supported by the Ph.D. Programs Foundation of Ministry of Education of China under Grant No.20090001110005the National Natural Science Foundation of China under Grant No.11171007
文摘Ovarian cancer is one of the most deadly female genital malignant tumors in many regions while an effective early screening strategy can save numerous lives.CA125 and HE4 are tumor markers validated efficacious as well as most commonly used in recent screening research of ovarian cancer.In this paper,the authors construct a change-point and mixture model on the basis of longitudinal CA125 and HE4 levels and estimated parameters using maximum likelihood method with the preclinical duration assumed right-censored,which is more adaptive and yields comparable results in comparison to the Bayesian approach raised by Skates.Consistency of estimators is proved.The authors also run a 5-year simulation of sequential screening by calculating the risk of cancer and hypothesis testing the true incidence time respectively.Results show that diagnosis based on hypothesis test performs better in early detection.