Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method...Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz.展开更多
Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The prin...Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No. 11204242 China Postdoctoral Foundation under Grant No. 2011M501477
文摘Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz.
基金supported by the National Natural Science Foundation of China(No.61377088)the Natural Science Foundation of Hebei Province of China(Nos.E2015502053 and F2015502059)the Fundamental Research Funds for the Central Universities(No.2016XS104)
文摘Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.