This paper deals with the competitiveness of Chinese agricultural products, base on the index of revealed comparative advantage (RCA) using lots of data for the period of 1980 to 2003. The index is useful in identifyi...This paper deals with the competitiveness of Chinese agricultural products, base on the index of revealed comparative advantage (RCA) using lots of data for the period of 1980 to 2003. The index is useful in identifying the demarcation between comparative advantage and comparative disadvantage. The research indicates that some agro-products in China such as edible vegetables and tea have a comparative advantage, but the RCA values have been declining over the 24-year period, which has vast impacts on future reform in China’s agricultural structure.展开更多
Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.T he purpose of this study is to compare th...Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.T he purpose of this study is to compare the6-month follow-up results between o ld and new Multilink stents with the method of intravascular ultrasound(IVUS)imaging.Methods.We have performed old(n =40)and new(n =35)Multilink stent implantations on 75patients with coronary artery disease.Coron ary angiography was performed before,immediately after,and 6months after the in-stent procedure respectively.Six-month follow-up IVUS imaging was performed and analyzed off-line.Results.Minimal lumen cross sectional area(CSA)of new Multilink stents was signific antly larger than that of old Multilink stents(P=0.0053).Mean stent lumen area of new Multili nk stents was significantly larger than that of old Multilink stents(P=0.040).Similarly,minimal lumen diameter(MLD)of new Multilink stents was larger than that of old Mul tilink stents(P=0.011).Old Multilink stents had a higher percentage of plaque area than new Multilink stent s.Conclusion.The new Multilink stent is obviously superior to old Multilink stents,in particular,in the stent MLD and lumen CSA---major determinants of the restenosis.展开更多
The response of an optical strain sensor based on the fiber Bragg grating is theoretically analyzed with a different approach of that found usually in the literature. In this model, geometrical changes suffered by the...The response of an optical strain sensor based on the fiber Bragg grating is theoretically analyzed with a different approach of that found usually in the literature. In this model, geometrical changes suffered by the grating itself are taken into account. The results are compared with those from experiments, showing very good agreement.展开更多
文摘This paper deals with the competitiveness of Chinese agricultural products, base on the index of revealed comparative advantage (RCA) using lots of data for the period of 1980 to 2003. The index is useful in identifying the demarcation between comparative advantage and comparative disadvantage. The research indicates that some agro-products in China such as edible vegetables and tea have a comparative advantage, but the RCA values have been declining over the 24-year period, which has vast impacts on future reform in China’s agricultural structure.
文摘Objective.It was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia.T he purpose of this study is to compare the6-month follow-up results between o ld and new Multilink stents with the method of intravascular ultrasound(IVUS)imaging.Methods.We have performed old(n =40)and new(n =35)Multilink stent implantations on 75patients with coronary artery disease.Coron ary angiography was performed before,immediately after,and 6months after the in-stent procedure respectively.Six-month follow-up IVUS imaging was performed and analyzed off-line.Results.Minimal lumen cross sectional area(CSA)of new Multilink stents was signific antly larger than that of old Multilink stents(P=0.0053).Mean stent lumen area of new Multili nk stents was significantly larger than that of old Multilink stents(P=0.040).Similarly,minimal lumen diameter(MLD)of new Multilink stents was larger than that of old Mul tilink stents(P=0.011).Old Multilink stents had a higher percentage of plaque area than new Multilink stent s.Conclusion.The new Multilink stent is obviously superior to old Multilink stents,in particular,in the stent MLD and lumen CSA---major determinants of the restenosis.
文摘The response of an optical strain sensor based on the fiber Bragg grating is theoretically analyzed with a different approach of that found usually in the literature. In this model, geometrical changes suffered by the grating itself are taken into account. The results are compared with those from experiments, showing very good agreement.