Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1250 TTE vid...Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1250 TTE videos from 402 patients were retrospectively collected,including 490 apical four chamber(A4C),310 parasternal long axis view of left ventricle(PLAX)and 450 parasternal short axis view of great vessel(PSAX GV).The videos were divided into development set(245 A4C,155 PLAX,225 PSAX GV),semi-automated training set(98 A4C,62 PLAX,90 PSAX GV)and test set(147 A4C,93 PLAX,135 PSAX GV)at the ratio of 5∶2∶3.Based on development set and semi-automatic training set,DL model of quality control was semi-automatically iteratively optimized,and a semi-automatic training system was constructed,then the efficacy of DL models for recognizing TTE views and assessing imaging quality of TTE were verified in test set.Results After optimization,the overall accuracy,precision,recall,and F1 score of DL models for recognizing TTE views in test set improved from 97.33%,97.26%,97.26%and 97.26%to 99.73%,99.65%,99.77%and 99.71%,respectively,while the overall accuracy for assessing A4C,PLAX and PSAX GV TTE as standard views in test set improved from 89.12%,83.87%and 90.37%to 93.20%,90.32%and 93.33%,respectively.Conclusion The developed DL models semi-automatic training system could improve the efficiency of clinical imaging quality control of TTE and increase iteration speed.展开更多
Sensory evaluation is the evaluation of signals that a buman receives via its sensory organs. Nowadays sensory evaluation is widely used in quality inspection and quality control of products. and many other fields. Ac...Sensory evaluation is the evaluation of signals that a buman receives via its sensory organs. Nowadays sensory evaluation is widely used in quality inspection and quality control of products. and many other fields. Actually sensory evaluation always give. uncertain and inprecise results, therefore it derivates many problems. we reviews in detail these problem and give some cumputing methods to resolve them.展开更多
This study proposesan over all framework for applying wireless manufacturing(WM)technologies in a smart factory and establishes a smart factory data computing and information using system (dc-IUS). Several plug-and-pl...This study proposesan over all framework for applying wireless manufacturing(WM)technologies in a smart factory and establishes a smart factory data computing and information using system (dc-IUS). Several plug-and-play (PnP) application modules of the dc-IUS are presented in the fields of machining process and quality control,material flow and inventory control,and factory resource tracking. Different schemes are discussed about how and where to apply these functions. Then some running examples are studied to demonstrate the feasibility and reliability of dc-IUS. At last,the challenges of applying WM are discussed and a conclusion is given.展开更多
文摘Objective To explore the value of deep learning(DL)models semi-automatic training system for automatic optimization of clinical image quality control of transthoracic echocardiography(TTE).Methods Totally 1250 TTE videos from 402 patients were retrospectively collected,including 490 apical four chamber(A4C),310 parasternal long axis view of left ventricle(PLAX)and 450 parasternal short axis view of great vessel(PSAX GV).The videos were divided into development set(245 A4C,155 PLAX,225 PSAX GV),semi-automated training set(98 A4C,62 PLAX,90 PSAX GV)and test set(147 A4C,93 PLAX,135 PSAX GV)at the ratio of 5∶2∶3.Based on development set and semi-automatic training set,DL model of quality control was semi-automatically iteratively optimized,and a semi-automatic training system was constructed,then the efficacy of DL models for recognizing TTE views and assessing imaging quality of TTE were verified in test set.Results After optimization,the overall accuracy,precision,recall,and F1 score of DL models for recognizing TTE views in test set improved from 97.33%,97.26%,97.26%and 97.26%to 99.73%,99.65%,99.77%and 99.71%,respectively,while the overall accuracy for assessing A4C,PLAX and PSAX GV TTE as standard views in test set improved from 89.12%,83.87%and 90.37%to 93.20%,90.32%and 93.33%,respectively.Conclusion The developed DL models semi-automatic training system could improve the efficiency of clinical imaging quality control of TTE and increase iteration speed.
文摘Sensory evaluation is the evaluation of signals that a buman receives via its sensory organs. Nowadays sensory evaluation is widely used in quality inspection and quality control of products. and many other fields. Actually sensory evaluation always give. uncertain and inprecise results, therefore it derivates many problems. we reviews in detail these problem and give some cumputing methods to resolve them.
基金National Natural Science Foundation of China(No.50875204)National Basic Research "973" Project(No.2011CB706805)
文摘This study proposesan over all framework for applying wireless manufacturing(WM)technologies in a smart factory and establishes a smart factory data computing and information using system (dc-IUS). Several plug-and-play (PnP) application modules of the dc-IUS are presented in the fields of machining process and quality control,material flow and inventory control,and factory resource tracking. Different schemes are discussed about how and where to apply these functions. Then some running examples are studied to demonstrate the feasibility and reliability of dc-IUS. At last,the challenges of applying WM are discussed and a conclusion is given.