FI system was used for the determination of histamine. A mini-column filled with amberlite resin (weak cation exchanger) was introduced to the flow system. A 200 laL of the sample was injected into the carrier strea...FI system was used for the determination of histamine. A mini-column filled with amberlite resin (weak cation exchanger) was introduced to the flow system. A 200 laL of the sample was injected into the carrier stream through the injection valve. The merged streams were passed through a quartz flow cell in a spectrophotometer connected to recorder. Under the optimum conditions, the calibration curve was linear in the range 0.02-1.5 μg mL^-1 of histamine using the peak height as an analytical signal, while the detection limit was 0.01 μg mL^-1. The precision and accuracy of the method were studied depending upon the values of the relative standard deviation and relative error percentage. The selectivity of the method was investigated by studying the effect of interference from other species accompanied with histamine in fish meal. Under the optimum conditions, the system was used for on line separation, preconcentration of histamine. The proposed method was applied for the determination of histamine in fish meal. The results were compared with the standard method and a good agreement between the results was obtained.展开更多
A new kinetic spectrophotometric method is developed for the measurement of manganese(Ⅱ) in water. The method is based on the catalytic effect of manganese(Ⅱ) with the oxidation of weak acid brilliant blue dye(RAWL)...A new kinetic spectrophotometric method is developed for the measurement of manganese(Ⅱ) in water. The method is based on the catalytic effect of manganese(Ⅱ) with the oxidation of weak acid brilliant blue dye(RAWL) by KIO4 using the Nitrilo triacetic acid(NTA) as an activation reagent. The optimum conditions obtained are 40 mgL-1 RAWL,1×10-4molL-1 KIO4,2×10-4 molL-1 Nitrilo triacetic acid(NTA),pH = 5.8,the reaction time of 3.00 min and the temperature of 20.0 ℃. Under the optimum conditions,the proposed method allows the measurement of manganese(Ⅱ) in a range of 0-50.0 ng mL-1 and with a detection limit of down to 0.158 ng mL-1. The recovery efficiency in measuring the standard manganese(Ⅱ) solution is in a range of 98.5%-102%,and the RSD is in a range of 0.76%-1.25%. The new method has been successfully applied to the measurement of manganese(Ⅱ) in both fresh water and seawater samples with satisfying results. Moreover,few cations and anions interfere with the measurement of manganese(Ⅱ). Compared with other kinetic catalytic methods and instrumental methods,the proposed method shows fairly good selectivity and sensitivity,low cost,cheapness,low detection limit and rapidity. It can be applied on boats easily.展开更多
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss...The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.展开更多
A family of stable mixed finite elements for the linear elasticity on tetrahedral grids are constructed,where the stress is approximated by symmetric H(div)-Pk polynomial tensors and the displacement is approximated b...A family of stable mixed finite elements for the linear elasticity on tetrahedral grids are constructed,where the stress is approximated by symmetric H(div)-Pk polynomial tensors and the displacement is approximated by C-1-Pk-1polynomial vectors,for all k 4.The main ingredients for the analysis are a new basis of the space of symmetric matrices,an intrinsic H(div)bubble function space on each element,and a new technique for establishing the discrete inf-sup condition.In particular,they enable us to prove that the divergence space of the H(div)bubble function space is identical to the orthogonal complement space of the rigid motion space with respect to the vector-valued Pk-1polynomial space on each tetrahedron.The optimal error estimate is proved,verified by numerical examples.展开更多
文摘FI system was used for the determination of histamine. A mini-column filled with amberlite resin (weak cation exchanger) was introduced to the flow system. A 200 laL of the sample was injected into the carrier stream through the injection valve. The merged streams were passed through a quartz flow cell in a spectrophotometer connected to recorder. Under the optimum conditions, the calibration curve was linear in the range 0.02-1.5 μg mL^-1 of histamine using the peak height as an analytical signal, while the detection limit was 0.01 μg mL^-1. The precision and accuracy of the method were studied depending upon the values of the relative standard deviation and relative error percentage. The selectivity of the method was investigated by studying the effect of interference from other species accompanied with histamine in fish meal. Under the optimum conditions, the system was used for on line separation, preconcentration of histamine. The proposed method was applied for the determination of histamine in fish meal. The results were compared with the standard method and a good agreement between the results was obtained.
文摘A new kinetic spectrophotometric method is developed for the measurement of manganese(Ⅱ) in water. The method is based on the catalytic effect of manganese(Ⅱ) with the oxidation of weak acid brilliant blue dye(RAWL) by KIO4 using the Nitrilo triacetic acid(NTA) as an activation reagent. The optimum conditions obtained are 40 mgL-1 RAWL,1×10-4molL-1 KIO4,2×10-4 molL-1 Nitrilo triacetic acid(NTA),pH = 5.8,the reaction time of 3.00 min and the temperature of 20.0 ℃. Under the optimum conditions,the proposed method allows the measurement of manganese(Ⅱ) in a range of 0-50.0 ng mL-1 and with a detection limit of down to 0.158 ng mL-1. The recovery efficiency in measuring the standard manganese(Ⅱ) solution is in a range of 98.5%-102%,and the RSD is in a range of 0.76%-1.25%. The new method has been successfully applied to the measurement of manganese(Ⅱ) in both fresh water and seawater samples with satisfying results. Moreover,few cations and anions interfere with the measurement of manganese(Ⅱ). Compared with other kinetic catalytic methods and instrumental methods,the proposed method shows fairly good selectivity and sensitivity,low cost,cheapness,low detection limit and rapidity. It can be applied on boats easily.
基金Project(21075138) supported by the National Natural Science Foundation of ChinaProject(cstc2011jjA0780) supported by Natural Science Foundation of Chongqing City,ChinaProject(KJ121311) supported by Educational Commission of Chongqing City of China
文摘The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.
基金supported by National Natural Science Foundation of China(Grant Nos.11271035,91430213 and 11421101)
文摘A family of stable mixed finite elements for the linear elasticity on tetrahedral grids are constructed,where the stress is approximated by symmetric H(div)-Pk polynomial tensors and the displacement is approximated by C-1-Pk-1polynomial vectors,for all k 4.The main ingredients for the analysis are a new basis of the space of symmetric matrices,an intrinsic H(div)bubble function space on each element,and a new technique for establishing the discrete inf-sup condition.In particular,they enable us to prove that the divergence space of the H(div)bubble function space is identical to the orthogonal complement space of the rigid motion space with respect to the vector-valued Pk-1polynomial space on each tetrahedron.The optimal error estimate is proved,verified by numerical examples.