亚德诺半导体公司宣布推出Power by Linear?的有源整流器控制器LT8672,该器件具有至–40V的反向输入保护。其3V至42V输入电压能力非常适合汽车应用,这类应用具低至3.0V的最低输入电压和高达40V的抛载瞬变,在冷车发动和停-启情况下,必须...亚德诺半导体公司宣布推出Power by Linear?的有源整流器控制器LT8672,该器件具有至–40V的反向输入保护。其3V至42V输入电压能力非常适合汽车应用,这类应用具低至3.0V的最低输入电压和高达40V的抛载瞬变,在冷车发动和停-启情况下,必须始终保持稳定。LT8672驱动一个外部N沟道MOSFET,具20m V压差,与肖特基二极管相比,功耗可降低90%,无需昂贵的散热器。汽车应用要求在高达100k Hz范围内对AC输入纹波整流。展开更多
To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current i...To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.展开更多
To solve the input current harmonic pollution of the high power rectifier system,18-pulse rectifier based on a kind of active harmonic suppression technique at dc side is proposed in this paper.The pulse rectifier emp...To solve the input current harmonic pollution of the high power rectifier system,18-pulse rectifier based on a kind of active harmonic suppression technique at dc side is proposed in this paper.The pulse rectifier employs three-phase diode bridges,each of them followed by a boost converter.Unlike the conventional three-phase unity-power-factor diode rectifier,the ideal sinusoidal main currents of circuit topology are obtained by control its output current or input currents of three boost converters for approximately triangular modulation.The theoretical of modulation strategy and characteristics of input and output currents about the proposed rectifier are analyzed in detail.Simulation results by Matlab/Simulink demonstrate that the proposed rectifier draws nearly sinusoidal current and power quality index is improved.The correctness of the theoretical analysis is validated.展开更多
文摘亚德诺半导体公司宣布推出Power by Linear?的有源整流器控制器LT8672,该器件具有至–40V的反向输入保护。其3V至42V输入电压能力非常适合汽车应用,这类应用具低至3.0V的最低输入电压和高达40V的抛载瞬变,在冷车发动和停-启情况下,必须始终保持稳定。LT8672驱动一个外部N沟道MOSFET,具20m V压差,与肖特基二极管相比,功耗可降低90%,无需昂贵的散热器。汽车应用要求在高达100k Hz范围内对AC输入纹波整流。
基金National Natural Science Foundation of China(No.51767013)Science and Technology Research and Development Plan of China Railway Corporation(No.2017J012-A)Lanzhou City Science and Technology Program for Innovation and Entrepreneurship of Talents(No.2017-RC-51)。
文摘To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.
基金Natural Science Foundation of Gansu Province Education Department(No.2017A-020)National Natural Science Foundation of China(No.51767013)Science and Technology Research and Development Plan of China Railway Corporation(No.2017J012-A)
文摘To solve the input current harmonic pollution of the high power rectifier system,18-pulse rectifier based on a kind of active harmonic suppression technique at dc side is proposed in this paper.The pulse rectifier employs three-phase diode bridges,each of them followed by a boost converter.Unlike the conventional three-phase unity-power-factor diode rectifier,the ideal sinusoidal main currents of circuit topology are obtained by control its output current or input currents of three boost converters for approximately triangular modulation.The theoretical of modulation strategy and characteristics of input and output currents about the proposed rectifier are analyzed in detail.Simulation results by Matlab/Simulink demonstrate that the proposed rectifier draws nearly sinusoidal current and power quality index is improved.The correctness of the theoretical analysis is validated.