介绍了EWB(Electronic Work Bench)软件的特点,给出了高阶有源滤波器设计的一般思路,用EWB软件设计出五阶巴特沃斯低通滤波器,其电路简单明了,参数容易确定,且电路调试方便。并且通过实际电路实验证明设计方法合理,设计出的滤波器满足...介绍了EWB(Electronic Work Bench)软件的特点,给出了高阶有源滤波器设计的一般思路,用EWB软件设计出五阶巴特沃斯低通滤波器,其电路简单明了,参数容易确定,且电路调试方便。并且通过实际电路实验证明设计方法合理,设计出的滤波器满足技术指标。该有源滤波器设计方法对信号处理,通信及检测技术方面有实用价值。展开更多
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act...For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.展开更多
An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structu...An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme.展开更多
An RF bandpass filter with a Q-enhancement active inductor is presented. The design technique for a tunable Q-enhancement CMOS active inductor operating in the wide RF-band is described. Moreover,issues related to noi...An RF bandpass filter with a Q-enhancement active inductor is presented. The design technique for a tunable Q-enhancement CMOS active inductor operating in the wide RF-band is described. Moreover,issues related to noise and stability of the active inductor are explained. The filter was fabricated in 0.18μm CMOS technolo- gy,and the circuit occupied an active area of only 150μm ×200μm. Measurement results show that the filter centered at 2. 44GHz with about 60MHz bandwidth (3dB) is tunable in center frequency from about 2.07 to 2. 44GHz. The ldB compression point is - 15dBm while consuming 10. 8mW of DC power,and a maximum quality factor of 103 is attained at the center frequency of 2.07GHz.展开更多
This paper describes a complete baseband chain for both GSM and WCDMA receivers with a SMIC 0.35μm mixed signal process. The chain consists of a dual-mode,highly linear, fourth order Chebyshev active RC filter and th...This paper describes a complete baseband chain for both GSM and WCDMA receivers with a SMIC 0.35μm mixed signal process. The chain consists of a dual-mode,highly linear, fourth order Chebyshev active RC filter and three VGA stages. The filter is designed to meet the bandwidth specifications of the GSM and WCDMA standards and share the maximum number of components between the two modes to reduce manufacturing cost. The design is free of DC-offset and has an inter-stage high-pass filter, and operational amplifiers with adjustable GBW are used to minimize GSM-mode power consumption. The measured noise figures are 27. 3 and 42dBm in WCDMA and GSM modes,respectively, at the maximum gain. The IIP3 is 40dBm at unit gain in the WCDMA mode,and the circuit consumes 47.0mW. The IIP3 is 28dBm in the GSM mode,and the circuit consumes 31.8mW. The supply voltage is 3.3V.展开更多
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous...A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.展开更多
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l...For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy.展开更多
Studied the harmonic control of the 6 kV power grid in a coal mine substation.Taking harmonic suppression and reactive power compensation into account, and complyingwith the economic and efficient technical line of th...Studied the harmonic control of the 6 kV power grid in a coal mine substation.Taking harmonic suppression and reactive power compensation into account, and complyingwith the economic and efficient technical line of the smart grid, a new hybrid activefilter was proposed and applied to the power grid in the coal mine with the advantagessuch as large capacity, low cost and low loss.In order to improve detection speed and reducethe succeeding errors to improve the filtering performance of the active power filter,the DFT (Discrete Fourier Transform) sliding window algorithm based on coordinatetransformation and improved hysteresis control method was proposed.The Matlab simulationresults show that the hybrid active filter is satisfactory, can improve the grid powerfactor and can meet the requirements of improving the power quality in the coal mine.展开更多
A 3rd-order Butterworth active-RC complex band-pass filter was presented for Zig Bee(IEEE802.15.4) transceiver applications. The filter adopted cascaded complex pole stages to realize the 3 MHz bandwidth with a centre...A 3rd-order Butterworth active-RC complex band-pass filter was presented for Zig Bee(IEEE802.15.4) transceiver applications. The filter adopted cascaded complex pole stages to realize the 3 MHz bandwidth with a centre frequency of 2 MHz which was required by the Zig Bee transceiver applications. An automatic frequency tuning scheme was also designed to accommodate the performance deterioration due to the process, voltage and temperature(PVT) variations. The whole filter is implemented in a 0.18 μm standard process and occupies an area of 1.3 mm×0.6 mm. The current dissipation is 1.2 m A from a 1.8 V single power supply. Measurement results show that the image rejection ratio(IRR) of the filter is 24.1 d B with a pass-band ripple less than 0.3 d B. The adjacent channel rejection is 29.8 d B@7 MHz and alternate channel rejection 47.5 d B@12 MHz, respectively.展开更多
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str...The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.展开更多
A 4th-order low-pass filter (LPF) based on active-Gm-RC structure for multi-standard system application is presented in this paper. The performances of LPF are controlled by a 1-bit control- voltage, and the cut-off...A 4th-order low-pass filter (LPF) based on active-Gm-RC structure for multi-standard system application is presented in this paper. The performances of LPF are controlled by a 1-bit control- voltage, and the cut-off frequency, channel selectivity, and linearity of the proposed filter can be reconfigured accordingly. In order to improve the accuracy of the cut-off frequency, a binary-weigh- ted switched-capacitor array is employed as the auto-tuning circuits to calibrate the RC-time con- stant. Fabricated in TSMC 0. 18μm RF CMOS process, the proposed LPF achieves a measured cutoff frequency of 1.95 and 12.3MHz for WCDMA and GPS/Galileo application with a bandwidth de viation less than 4%. The measured l dB compression points are -3.0dBm and -5.1 dBm respectively for different modes. The core circuit of LPF consumes l mW and 1.6mW for WCDMA and GPS/Galileo respectively. And the proposed LPF occupies an area of 0.78ram2.展开更多
In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach h...In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.展开更多
There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF),which has a great influence on the reasonable selection of various parameter values.By analy...There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF),which has a great influence on the reasonable selection of various parameter values.By analyzing the calculation methods of the inductance of alternating current(AC)side and the voltage and capacitance values of direct current(DC)side in the existing single/three-phase SAPF main circuit,a specific single-phase SAPF circuit parameter analytical expression was obtained.Aiming at the coupling relationship among the variables in the resulting expression,the model was optimized and analyzed in MATLAB,and a complete set of parameters design scheme was obtained,which ensure the comprehensive optimization target of the post-harmonic content below 2% is compensated under a specific load.The simulation and experimental procedures verify the correctness of the selected parameters.展开更多
文摘介绍了EWB(Electronic Work Bench)软件的特点,给出了高阶有源滤波器设计的一般思路,用EWB软件设计出五阶巴特沃斯低通滤波器,其电路简单明了,参数容易确定,且电路调试方便。并且通过实际电路实验证明设计方法合理,设计出的滤波器满足技术指标。该有源滤波器设计方法对信号处理,通信及检测技术方面有实用价值。
文摘For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.
基金The National Basic Research Program of China(973 Program)(No.2013CB035603)the National Natural Science Foundation of China(No.51007008,51137001)+1 种基金the Ph.D.Programs Foundation of Ministry of Education of China(No.20100092120043)the Fundamental Research Funds for the Central Universities
文摘An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme.
文摘An RF bandpass filter with a Q-enhancement active inductor is presented. The design technique for a tunable Q-enhancement CMOS active inductor operating in the wide RF-band is described. Moreover,issues related to noise and stability of the active inductor are explained. The filter was fabricated in 0.18μm CMOS technolo- gy,and the circuit occupied an active area of only 150μm ×200μm. Measurement results show that the filter centered at 2. 44GHz with about 60MHz bandwidth (3dB) is tunable in center frequency from about 2.07 to 2. 44GHz. The ldB compression point is - 15dBm while consuming 10. 8mW of DC power,and a maximum quality factor of 103 is attained at the center frequency of 2.07GHz.
文摘This paper describes a complete baseband chain for both GSM and WCDMA receivers with a SMIC 0.35μm mixed signal process. The chain consists of a dual-mode,highly linear, fourth order Chebyshev active RC filter and three VGA stages. The filter is designed to meet the bandwidth specifications of the GSM and WCDMA standards and share the maximum number of components between the two modes to reduce manufacturing cost. The design is free of DC-offset and has an inter-stage high-pass filter, and operational amplifiers with adjustable GBW are used to minimize GSM-mode power consumption. The measured noise figures are 27. 3 and 42dBm in WCDMA and GSM modes,respectively, at the maximum gain. The IIP3 is 40dBm at unit gain in the WCDMA mode,and the circuit consumes 47.0mW. The IIP3 is 28dBm in the GSM mode,and the circuit consumes 31.8mW. The supply voltage is 3.3V.
基金Project(JC200903180555A) supported by Shenzhen City Science and Technology Plan, China
文摘A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient.
基金Project(51107111)supported by the National Natural Science Foundation of China
文摘For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy.
文摘Studied the harmonic control of the 6 kV power grid in a coal mine substation.Taking harmonic suppression and reactive power compensation into account, and complyingwith the economic and efficient technical line of the smart grid, a new hybrid activefilter was proposed and applied to the power grid in the coal mine with the advantagessuch as large capacity, low cost and low loss.In order to improve detection speed and reducethe succeeding errors to improve the filtering performance of the active power filter,the DFT (Discrete Fourier Transform) sliding window algorithm based on coordinatetransformation and improved hysteresis control method was proposed.The Matlab simulationresults show that the hybrid active filter is satisfactory, can improve the grid powerfactor and can meet the requirements of improving the power quality in the coal mine.
基金Projects(61334003,61274026) supported by the National Natural Science Foundation of ChinaProject(K5051225006) supported by the Fundamental Research Fund for the Central Universities,China
文摘A 3rd-order Butterworth active-RC complex band-pass filter was presented for Zig Bee(IEEE802.15.4) transceiver applications. The filter adopted cascaded complex pole stages to realize the 3 MHz bandwidth with a centre frequency of 2 MHz which was required by the Zig Bee transceiver applications. An automatic frequency tuning scheme was also designed to accommodate the performance deterioration due to the process, voltage and temperature(PVT) variations. The whole filter is implemented in a 0.18 μm standard process and occupies an area of 1.3 mm×0.6 mm. The current dissipation is 1.2 m A from a 1.8 V single power supply. Measurement results show that the image rejection ratio(IRR) of the filter is 24.1 d B with a pass-band ripple less than 0.3 d B. The adjacent channel rejection is 29.8 d B@7 MHz and alternate channel rejection 47.5 d B@12 MHz, respectively.
基金National Natural Science Foundation of China(No.51767014)China Railway Corporation of Science and Technology Research and Development Projects(No.2016J010-C)
文摘The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.
基金Supported by the National Basic Research Program of China(No.2010CB327404)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘A 4th-order low-pass filter (LPF) based on active-Gm-RC structure for multi-standard system application is presented in this paper. The performances of LPF are controlled by a 1-bit control- voltage, and the cut-off frequency, channel selectivity, and linearity of the proposed filter can be reconfigured accordingly. In order to improve the accuracy of the cut-off frequency, a binary-weigh- ted switched-capacitor array is employed as the auto-tuning circuits to calibrate the RC-time con- stant. Fabricated in TSMC 0. 18μm RF CMOS process, the proposed LPF achieves a measured cutoff frequency of 1.95 and 12.3MHz for WCDMA and GPS/Galileo application with a bandwidth de viation less than 4%. The measured l dB compression points are -3.0dBm and -5.1 dBm respectively for different modes. The core circuit of LPF consumes l mW and 1.6mW for WCDMA and GPS/Galileo respectively. And the proposed LPF occupies an area of 0.78ram2.
文摘In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.
基金National Natural Science Foundation of China(No.51367010)Science and Technology Program of Gansu Province(No.17JR5RA083)+2 种基金Natural Science Foundation of Gansu Province(No.1610RJZA042)Program for Excellent Team of Scientific Research in Lanzhou Jiaotong University(No.201701)Scientific Research Program of Colleges and Universities in Gansu Province(No.2016B-032)。
文摘There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF),which has a great influence on the reasonable selection of various parameter values.By analyzing the calculation methods of the inductance of alternating current(AC)side and the voltage and capacitance values of direct current(DC)side in the existing single/three-phase SAPF main circuit,a specific single-phase SAPF circuit parameter analytical expression was obtained.Aiming at the coupling relationship among the variables in the resulting expression,the model was optimized and analyzed in MATLAB,and a complete set of parameters design scheme was obtained,which ensure the comprehensive optimization target of the post-harmonic content below 2% is compensated under a specific load.The simulation and experimental procedures verify the correctness of the selected parameters.