This paper analyzes of the bottleneck to influence the running efficiency of educational administration system in universities and colleges,and from the system deployment architecture, server configuration, database S...This paper analyzes of the bottleneck to influence the running efficiency of educational administration system in universities and colleges,and from the system deployment architecture, server configuration, database SQL statement optimization and other aspects, it puts forwards the optimization scheme.展开更多
In this study,an explicit adaptive traffic allocation scheme for Machine-to-Machine(M2M)service is proposed to achieve optimum distribution in heterogeneous networks.Based on the characteristics of M2M services,the pr...In this study,an explicit adaptive traffic allocation scheme for Machine-to-Machine(M2M)service is proposed to achieve optimum distribution in heterogeneous networks.Based on the characteristics of M2M services,the presented scheme is formulated as a convex optimization problem that maximises the utility of the M2M service,and then determines how to allocate the total rate among the multiple access networks.The analysis and numerical simulations indicate that the proposed scheme makes a significant improvement in performance compared with the traditional schemes.展开更多
Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increas...Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).展开更多
基金Acknowledgement Research of the nature science foundation of Shandong province has a triangular surface modeling and control display representation(No. ZR2012FL05)
文摘This paper analyzes of the bottleneck to influence the running efficiency of educational administration system in universities and colleges,and from the system deployment architecture, server configuration, database SQL statement optimization and other aspects, it puts forwards the optimization scheme.
基金supported by the National Natural Science Foundation of Chinaunder Grant No.60971125the National Science and Technology Major Project of the Ministry of Science and Technology of Chinaunder Grant No.2012ZX03005-010the China Scholarship Council
文摘In this study,an explicit adaptive traffic allocation scheme for Machine-to-Machine(M2M)service is proposed to achieve optimum distribution in heterogeneous networks.Based on the characteristics of M2M services,the presented scheme is formulated as a convex optimization problem that maximises the utility of the M2M service,and then determines how to allocate the total rate among the multiple access networks.The analysis and numerical simulations indicate that the proposed scheme makes a significant improvement in performance compared with the traditional schemes.
文摘Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).