Electromagnetic and mechanical forces are main reasons of oscillations in hydro-generators.The oscillation is fairly complicated as to the coupling of them.Using the method of multiple scales in nonlinear oscillations...Electromagnetic and mechanical forces are main reasons of oscillations in hydro-generators.The oscillation is fairly complicated as to the coupling of them.Using the method of multiple scales in nonlinear oscillations,instabilities of hydro-generator rotors caused by the unbalanced magnetic pull,which comes from the eccentricity of the rotor,are discussed.Considering nonlinear properties of the unbalanced magnetic pull,the super-harmonic resonance phenomena are observed as the critical rotating speed of rotors is close to twice of the operating speed.This is verified by a model experiment,and should be considered during the design of hydro-generator rotors.展开更多
This paper studies on the change mechanisms of the voltage stability caused by the grid connection of front-end speed-controlled wind turbines(FSCWT)integrating into power system.First of all,the differential algebrai...This paper studies on the change mechanisms of the voltage stability caused by the grid connection of front-end speed-controlled wind turbines(FSCWT)integrating into power system.First of all,the differential algebraic equations describing the dynamic characteristics of wind turbines are illustrated.Then,under the guidance of IEEE3 node system model,the influence of the angular velocity of wind turbines,the reactive power and the active power at load bus on the voltage stability of grid-connection has been analyzed by using bifurcation theory.Finally,the method of linear-state feedback control has been applied to the original system in accordance with the bifurcation phenomenon of grid-connected voltage caused by the increase in the active power at load bus.Research shows that voltage at the grid-connected point would be changed with the fluctuation of turbines angular velocity.And increasing its reactive power can enhance voltage at the grid-connected point;problem of bifurcation at the grid-connected point can be delayed when increasing the gain k s of feedback controller within a certain range.展开更多
Under certain load pattern, the geometrically indeterminate pin-jointed mechanisms will present certain shapes to keep static equalization. This paper proposes a matrix-based method to determine the mobility and equil...Under certain load pattern, the geometrically indeterminate pin-jointed mechanisms will present certain shapes to keep static equalization. This paper proposes a matrix-based method to determine the mobility and equilibrium stability of mechanisms according to the effects of the external loads. The first and second variations of the potential energy function of mechanisms under conservative force field are analyzed. Based on the singular value decomposition (SVD) method, a new crite- rion for the mobility and equilibrium stability of mechanisms can be concluded by analyzing the equilibrium matrix. The mobility and stability of mechanisms can be classified by unified matrix formulae. A number of examples are given to demonstrate the proposed criterion. In the end, criteria are summarized in a table.展开更多
This paper describes a stabilization effect after installating an adjustable speed generator (ASG) in a multi machine power system. A personal computer based ASG module has been de veloped for the simulations in...This paper describes a stabilization effect after installating an adjustable speed generator (ASG) in a multi machine power system. A personal computer based ASG module has been de veloped for the simulations in parallel with the analog power system simulator i n the Research Laboratory of the Kyushu Electric Power Co. The three phase ins t antaneous value based ASG model has been developed in the Matlab/Simulink envir onment for its detailed and real time simulations, which have been performed on a digital signal processor (DSP) board with AD and DA conversion interfaces inst alled in a personal computer (PC). Simulational results indicate the hig hly improved overall stability of the multi machine power system after installa ting the ASG.展开更多
Permanent magnetic actuator (PMA), as a new electronic actuator of vacuum circuit breakers, certainly will be used to replace the traditional mechanical actuator. It has such advantages as simple structure, high rel...Permanent magnetic actuator (PMA), as a new electronic actuator of vacuum circuit breakers, certainly will be used to replace the traditional mechanical actuator. It has such advantages as simple structure, high reliability, free maintenance, and so on. This paper summarizes the development, structure, magnetic analysis, character analysis, and control strategy of PMA, and also predicts the future trend of PMA development展开更多
Remarkable improvement in efficiency and stability has been observed in a doped organic electroluminescence device, which consists of a hole-transport layer, an electron-transport layer and a luminescent layer. The ho...Remarkable improvement in efficiency and stability has been observed in a doped organic electroluminescence device, which consists of a hole-transport layer, an electron-transport layer and a luminescent layer. The hole-transport layer is a N,N’-bis(3-methyphenyl)-N,N’-diphenylbenzidine film. The doped emitting layer consists of 8-(quinolinolate)-aluminum as the host and rubrene as the emission dopant. The doped device demonstrated a brightness in excess of 40 000 cd/m 2 and the maximum external quantum efficiency of 3.4%, which is about six times and four times respectively greater than those of the undoped device. For no packaged deviced, a luminance half-life on the order of about 230 h has been achieved under a constant current density of 15 mA/cm 2, starting at 500 cd/m 2 at the room temperature.展开更多
The static voltage stability of the power system integrating wind farms adopting different kinds of wind turbines is analyzed. Through the simulation of one certain local power grid in Xinjiang Uygur Autonomous Region...The static voltage stability of the power system integrating wind farms adopting different kinds of wind turbines is analyzed. Through the simulation of one certain local power grid in Xinjiang Uygur Autonomous Region, the PV curves at the point of common coupling (PCC), key buses and important substations are plotted; the variation of voltage as well as the limit and margin of static stability are analyzed. It is resulted from the simulation that the limit of static voltage at weak nodes is lower, and the static voltage of the power system with wind farms adopting doubly-fed induction generators (DFIG) is more stable than that with wind farms adopting common asynchronous generators.展开更多
An adaptive load torque observer is presented to compensate the torque ripple in PMSM servo system. A simple adaptive scheme is derived using Popov ' s hyperstability theory. The torque ripple detected by the observe...An adaptive load torque observer is presented to compensate the torque ripple in PMSM servo system. A simple adaptive scheme is derived using Popov ' s hyperstability theory. The torque ripple detected by the observer is compensated by a feed forwarding equivalent current which gives fast response. The noisy current information is exempt from the observer to avoid its deterioration to the quality of the observer. The speed measurement delay is considered by using observed speed sinee the instantaneous velocity can't be estimated precisely at low speed because of too few position pulses from the absolute encoder during one time interval. Simulation and experimental results demonstrate that the proposed method can improve the dynamic performance of PMSM servo system satisfyingly.展开更多
The eigenvalues analysis method is generally applied to synchronous machines by using d, q-components. This paper presents the application of this method on an equivalent model for the synchronous machine based on pha...The eigenvalues analysis method is generally applied to synchronous machines by using d, q-components. This paper presents the application of this method on an equivalent model for the synchronous machine based on phase variables a, b, c instead of d, q-components. The advantages of this approach, essential for programs using phase variables as state variables, are presented. The application of this method to a complete hydroelectric production site including hydraulic components (pump-turbine, penstock, gallery, reservoir...) permits the study and analysis of the interactions between the hydraulic, electric and regulation parts of the system. Results coming from the proposed eigenvalues analysis method and the numerical simulations confirm the interest of the presented approach.展开更多
The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magn...The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated.展开更多
Abstract: This paper describes the development and characterization of a two-temperature (2-T), constant pressure humidity generator It relies on the saturation of a stream of gas flowing over a water surface maint...Abstract: This paper describes the development and characterization of a two-temperature (2-T), constant pressure humidity generator It relies on the saturation of a stream of gas flowing over a water surface maintained at constant, well-known, temperature. It was built in order to improve the uncertainties of the dew-point temperature and humidity scales realization at the National Institute for Standard (NIS) in the dew-point range from -50 ℃ to + 10 ℃. Several experiments were carried out in the above mentioned range in order to characterize the generator. Characterization comprised studies of its saturator efficiency, temperature stability and a comparison with a calibrated chilled-mirror hygrometer. The results of the efficiency tests showed good performance of the generator as described below. For uncertainty of measurements, a thorough analysis was also described representing estimations of contributions for all the sources that affecting measurements.展开更多
Excitation system is one of the significant elements affecting the dynamic performance of electric power systems. The power engineering as area of science and industry is subjected to rapid modernization, which is cau...Excitation system is one of the significant elements affecting the dynamic performance of electric power systems. The power engineering as area of science and industry is subjected to rapid modernization, which is caused by technological progress. However, not all elements of the power system are developing simultaneously. The old type of elements sometimes is sufficient to adapt old system to the new operational conditions. The work developed and proposed in this paper deals with analysis of possible optimization of synchronous generator's excitation system. Authors examined influence of excitation system's parameters to the dynamics of transient processes in the power system. Authors investigated optimal parameters of excitation system of the Kegums hydro power plant. For optimization of parameters objective functions were used. The problem of the mutual influence of excitation systems of neighbor power plants was investigated. Investigation of transient processes using developed model proved that optimization of excitation parameters improves efficiency of regulation of excitation system, damping of active power oscillation and in some cases can prevent out-of-step condition.展开更多
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ...In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.59493700),Key Project of the National Tenth-Five Year Research Programme of China(Grant No.ZZ01-01-04-03).
文摘Electromagnetic and mechanical forces are main reasons of oscillations in hydro-generators.The oscillation is fairly complicated as to the coupling of them.Using the method of multiple scales in nonlinear oscillations,instabilities of hydro-generator rotors caused by the unbalanced magnetic pull,which comes from the eccentricity of the rotor,are discussed.Considering nonlinear properties of the unbalanced magnetic pull,the super-harmonic resonance phenomena are observed as the critical rotating speed of rotors is close to twice of the operating speed.This is verified by a model experiment,and should be considered during the design of hydro-generator rotors.
基金National Natural Science Foundation of China(No.61663019)
文摘This paper studies on the change mechanisms of the voltage stability caused by the grid connection of front-end speed-controlled wind turbines(FSCWT)integrating into power system.First of all,the differential algebraic equations describing the dynamic characteristics of wind turbines are illustrated.Then,under the guidance of IEEE3 node system model,the influence of the angular velocity of wind turbines,the reactive power and the active power at load bus on the voltage stability of grid-connection has been analyzed by using bifurcation theory.Finally,the method of linear-state feedback control has been applied to the original system in accordance with the bifurcation phenomenon of grid-connected voltage caused by the increase in the active power at load bus.Research shows that voltage at the grid-connected point would be changed with the fluctuation of turbines angular velocity.And increasing its reactive power can enhance voltage at the grid-connected point;problem of bifurcation at the grid-connected point can be delayed when increasing the gain k s of feedback controller within a certain range.
基金Project supported by the National Natural Science Foundation of China (Nos. 50378083 and 50638050)the Research Foundation for the Doctoral Program of Higher Education of China (No. 20050335097)
文摘Under certain load pattern, the geometrically indeterminate pin-jointed mechanisms will present certain shapes to keep static equalization. This paper proposes a matrix-based method to determine the mobility and equilibrium stability of mechanisms according to the effects of the external loads. The first and second variations of the potential energy function of mechanisms under conservative force field are analyzed. Based on the singular value decomposition (SVD) method, a new crite- rion for the mobility and equilibrium stability of mechanisms can be concluded by analyzing the equilibrium matrix. The mobility and stability of mechanisms can be classified by unified matrix formulae. A number of examples are given to demonstrate the proposed criterion. In the end, criteria are summarized in a table.
文摘This paper describes a stabilization effect after installating an adjustable speed generator (ASG) in a multi machine power system. A personal computer based ASG module has been de veloped for the simulations in parallel with the analog power system simulator i n the Research Laboratory of the Kyushu Electric Power Co. The three phase ins t antaneous value based ASG model has been developed in the Matlab/Simulink envir onment for its detailed and real time simulations, which have been performed on a digital signal processor (DSP) board with AD and DA conversion interfaces inst alled in a personal computer (PC). Simulational results indicate the hig hly improved overall stability of the multi machine power system after installa ting the ASG.
文摘Permanent magnetic actuator (PMA), as a new electronic actuator of vacuum circuit breakers, certainly will be used to replace the traditional mechanical actuator. It has such advantages as simple structure, high reliability, free maintenance, and so on. This paper summarizes the development, structure, magnetic analysis, character analysis, and control strategy of PMA, and also predicts the future trend of PMA development
基金The National Natural Science Foundation of China , National "863" P
文摘Remarkable improvement in efficiency and stability has been observed in a doped organic electroluminescence device, which consists of a hole-transport layer, an electron-transport layer and a luminescent layer. The hole-transport layer is a N,N’-bis(3-methyphenyl)-N,N’-diphenylbenzidine film. The doped emitting layer consists of 8-(quinolinolate)-aluminum as the host and rubrene as the emission dopant. The doped device demonstrated a brightness in excess of 40 000 cd/m 2 and the maximum external quantum efficiency of 3.4%, which is about six times and four times respectively greater than those of the undoped device. For no packaged deviced, a luminance half-life on the order of about 230 h has been achieved under a constant current density of 15 mA/cm 2, starting at 500 cd/m 2 at the room temperature.
基金National Natural Science Foundation of China(5076700350867004)Autonomous university research projects(XJEDU2007105)
文摘The static voltage stability of the power system integrating wind farms adopting different kinds of wind turbines is analyzed. Through the simulation of one certain local power grid in Xinjiang Uygur Autonomous Region, the PV curves at the point of common coupling (PCC), key buses and important substations are plotted; the variation of voltage as well as the limit and margin of static stability are analyzed. It is resulted from the simulation that the limit of static voltage at weak nodes is lower, and the static voltage of the power system with wind farms adopting doubly-fed induction generators (DFIG) is more stable than that with wind farms adopting common asynchronous generators.
文摘An adaptive load torque observer is presented to compensate the torque ripple in PMSM servo system. A simple adaptive scheme is derived using Popov ' s hyperstability theory. The torque ripple detected by the observer is compensated by a feed forwarding equivalent current which gives fast response. The noisy current information is exempt from the observer to avoid its deterioration to the quality of the observer. The speed measurement delay is considered by using observed speed sinee the instantaneous velocity can't be estimated precisely at low speed because of too few position pulses from the absolute encoder during one time interval. Simulation and experimental results demonstrate that the proposed method can improve the dynamic performance of PMSM servo system satisfyingly.
文摘The eigenvalues analysis method is generally applied to synchronous machines by using d, q-components. This paper presents the application of this method on an equivalent model for the synchronous machine based on phase variables a, b, c instead of d, q-components. The advantages of this approach, essential for programs using phase variables as state variables, are presented. The application of this method to a complete hydroelectric production site including hydraulic components (pump-turbine, penstock, gallery, reservoir...) permits the study and analysis of the interactions between the hydraulic, electric and regulation parts of the system. Results coming from the proposed eigenvalues analysis method and the numerical simulations confirm the interest of the presented approach.
文摘The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated.
文摘Abstract: This paper describes the development and characterization of a two-temperature (2-T), constant pressure humidity generator It relies on the saturation of a stream of gas flowing over a water surface maintained at constant, well-known, temperature. It was built in order to improve the uncertainties of the dew-point temperature and humidity scales realization at the National Institute for Standard (NIS) in the dew-point range from -50 ℃ to + 10 ℃. Several experiments were carried out in the above mentioned range in order to characterize the generator. Characterization comprised studies of its saturator efficiency, temperature stability and a comparison with a calibrated chilled-mirror hygrometer. The results of the efficiency tests showed good performance of the generator as described below. For uncertainty of measurements, a thorough analysis was also described representing estimations of contributions for all the sources that affecting measurements.
文摘Excitation system is one of the significant elements affecting the dynamic performance of electric power systems. The power engineering as area of science and industry is subjected to rapid modernization, which is caused by technological progress. However, not all elements of the power system are developing simultaneously. The old type of elements sometimes is sufficient to adapt old system to the new operational conditions. The work developed and proposed in this paper deals with analysis of possible optimization of synchronous generator's excitation system. Authors examined influence of excitation system's parameters to the dynamics of transient processes in the power system. Authors investigated optimal parameters of excitation system of the Kegums hydro power plant. For optimization of parameters objective functions were used. The problem of the mutual influence of excitation systems of neighbor power plants was investigated. Investigation of transient processes using developed model proved that optimization of excitation parameters improves efficiency of regulation of excitation system, damping of active power oscillation and in some cases can prevent out-of-step condition.
文摘In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated.