基于数据适应性检验的身管磨损量预测研究 被引量:1
1
作者 王国辉 赵硕 +1 位作者 李向荣 范鹏飞 《火力与指挥控制》 CSCD 北大核心 2017年第3期128-131,共4页
应用灰色系统理论研究不确定系统,对系统进行灰色预测模型建立的同时,需要检验系统原始数据序列是否符合建模要求。主要从3个方面检验数据建模的可行性,分别是光滑比、极比偏差和凹凸性检验。结合某型坦克炮身管内膛烧蚀磨损数据,采用... 应用灰色系统理论研究不确定系统,对系统进行灰色预测模型建立的同时,需要检验系统原始数据序列是否符合建模要求。主要从3个方面检验数据建模的可行性,分别是光滑比、极比偏差和凹凸性检验。结合某型坦克炮身管内膛烧蚀磨损数据,采用不同的磨损数据作为灰色预测模型建模的原始数据序列,具体分成两种情况进行数据检验,并代入模型计算,分析不同情况下模型的预测精度,通过对比计算结果选出与模型匹配度更高的原始数据序列。 展开更多
关键词 光滑比 极比偏差 凹凸性 灰色预测模型 身管磨损量
下载PDF
A disposable cobalt-based phosphate sensor based on screen printing technology
2
作者 SONG Lei ZHU Lei +2 位作者 LIU YanChen ZHOU XiaoHong SHI HanChang 《Science China Chemistry》 SCIE EI CAS 2014年第9期1283-1290,共8页
Screen printing is a promising technology because of its simplicity, low-cost, high reproducibility, and efficiency in large-scale production. In this work, a cobalt-based phosphate sensor was successfully fabricated ... Screen printing is a promising technology because of its simplicity, low-cost, high reproducibility, and efficiency in large-scale production. In this work, a cobalt-based phosphate sensor was successfully fabricated using the screen printing technology for the determination of phosphate concentration in the aqueous solution. The disposable sensor consists of a fully integrated cobalt (Co) electrode, which is a layer of carbon conductive ink (C) physically doped with Co powder, and Ag/AgCI reference electrode. The SEM images show that the morphology of the Co electrode changes after exposure to the phosphate solution, indicating that the expendable reaction exists during the measurement. At the Co/C ratio of 1:99, the cobalt-based phosphate sensor shows phosphate-selective potential response in the range of 10-4 to 10-1 mol/L, yielding a detection limit of lxl0-5 mol/L and a slope of over 30 mV/decade in acidic solution (pH 4.5) for HzPO4-. The proposed screen-printed sensor also ex- hibited significant reproducibility with a small repeated sensing deviation (i.e., relative standard deviation (R.S.D.) of 0.5%) on a single sensor and a small electrode-to-electrode deviation (i.e., R.S.D. 〈 3.2%). The recovery study of HzPO4- in real wastewater samples gave values from 95.4% to 101.8%, confirming its application potential in the measurement of phosphate in real samples. Apart from its high selectivity, sensitivity, and stability comparable with a conventional bulk Co-wire electrode, the proposed phosphate sensor still yields many other advantages, such as low price, compactness, ease of use, and the possibility of integration with other analytical devices such as flow injection analysis. 展开更多
关键词 phosphate sensor COBALT screen printing POTENTIOMETRY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部