Since the complex impeller structure and the difficult remanufacturing process may easily cause advance remanufacturing or excessive use,an optimized design method of impeller and service mapping model was presented f...Since the complex impeller structure and the difficult remanufacturing process may easily cause advance remanufacturing or excessive use,an optimized design method of impeller and service mapping model was presented for its proactive remanufacturing with setting up to explore the best remanufacturing time point in this work.Considering a certain model of long distance pipeline compressor impeller with the Basquin equation and the design method of impeller,the mathematical relationship between the changes of structure and life of the impeller was established.And the service mapping model between the structure and life was set up and simulated by ANSYS software.Thus,the service mapping model was applied to feedback the original design for proactive remanufacturing.In this work,the best proactive remanufacturing time point of impeller was analyzed with the service mapping model,and the structural parameter values could be optimized at this time point.Meanwhile,in the results of this simulation,it proves that the impeller under this optimization performance could satisfy the impeller operating demands.Therefore,comparing with the traditional optimization design method,the remanufacturing optimized design based on the service mapping model is feasible in proactive remanufacturing for sustainable development.展开更多
The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements o...The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls.展开更多
基金Project(2011CB013406)supported by National Basic Research Program of ChinaProjects(51305119,51375133)supported by National Natural Science Foundation of China
文摘Since the complex impeller structure and the difficult remanufacturing process may easily cause advance remanufacturing or excessive use,an optimized design method of impeller and service mapping model was presented for its proactive remanufacturing with setting up to explore the best remanufacturing time point in this work.Considering a certain model of long distance pipeline compressor impeller with the Basquin equation and the design method of impeller,the mathematical relationship between the changes of structure and life of the impeller was established.And the service mapping model between the structure and life was set up and simulated by ANSYS software.Thus,the service mapping model was applied to feedback the original design for proactive remanufacturing.In this work,the best proactive remanufacturing time point of impeller was analyzed with the service mapping model,and the structural parameter values could be optimized at this time point.Meanwhile,in the results of this simulation,it proves that the impeller under this optimization performance could satisfy the impeller operating demands.Therefore,comparing with the traditional optimization design method,the remanufacturing optimized design based on the service mapping model is feasible in proactive remanufacturing for sustainable development.
基金supported by the National Key Technology R&D Program of China(Grant No.2011BAJ09B01)the National Natural Science Foundation of China(Grant Nos.51178246,51222810)Tsinghua University Initiative Scientific Research Program(Grant No.20101081766)
文摘The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls.