To improve the classification performance of the kernel minimum squared error( KMSE), an enhanced KMSE algorithm( EKMSE) is proposed. It redefines the regular objective function by introducing a novel class label ...To improve the classification performance of the kernel minimum squared error( KMSE), an enhanced KMSE algorithm( EKMSE) is proposed. It redefines the regular objective function by introducing a novel class label definition, and the relative class label matrix can be adaptively adjusted to the kernel matrix.Compared with the common methods, the newobjective function can enlarge the distance between different classes, which therefore yields better recognition rates. In addition, an iteration parameter searching technique is adopted to improve the computational efficiency. The extensive experiments on FERET and GT face databases illustrate the feasibility and efficiency of the proposed EKMSE. It outperforms the original MSE, KMSE,some KMSE improvement methods, and even the sparse representation-based techniques in face recognition, such as collaborate representation classification( CRC).展开更多
In the measurement of liquid level in industrial site environment,noise interference can affect the measurement accuracy.In order to improve the measurement accuracy of liquid level in the viscous state,a nuclear radi...In the measurement of liquid level in industrial site environment,noise interference can affect the measurement accuracy.In order to improve the measurement accuracy of liquid level in the viscous state,a nuclear radiation level measurement system based on the least mean square(LMS)filtering correction method is designed.The system uses STM32F103 as the control core and adopts HART bus HT1200M chip for remote signal transmission and reception.The adaptive LMS algorithm can be used for more accurate filtering,calculating iterative weight vector,updating weighted coefficient,effectively removing system measurement noise and improving the measurement accuracy.The results show that the nuclear radiation level gauge based on normalized LMS can correct the measurement system accuracy in adaptive rules,improve the measurement accuracy to meet the requirements of industrial field environment for liquid level measurement and enhance the industrial automation control degree.展开更多
In this paper, we propose a new method that combines collage error in fractal domain and Hu moment invariants for image retrieval with a statistical method - variable bandwidth Kernel Density Estimation (KDE). The pro...In this paper, we propose a new method that combines collage error in fractal domain and Hu moment invariants for image retrieval with a statistical method - variable bandwidth Kernel Density Estimation (KDE). The proposed method is called CHK (KDE of Collage error and Hu moment) and it is tested on the Vistex texture database with 640 natural images. Experimental results show that the Average Retrieval Rate (ARR) can reach into 78.18%, which demonstrates that the proposed method performs better than the one with parameters respectively as well as the commonly used histogram method both on retrieval rate and retrieval time.展开更多
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi...This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.展开更多
文摘核数据协方差是评估核装置设计不确定度和核数据调整的重要输入,直接影响设计不确定度量化评估和核数据调整的结果。为测试基于不确定度源项分析和线性最小二乘法评价的235 U平滑区协方差数据的合理性,采用OECD/NEA WPEC/SG33提出的核数据调整基准例题和自主研发的核数据调整程序NDAC,开展了以JENDL-4.0库为基础的核数据调整测试,得到了应用了235 U cov版235 U数据的调整结果。测试结果显示,235 U cov版235 U数据的非弹性散射截面协方差不合理,阈能附近的不确定度过大;裂变和俘获截面的不确定度偏小。
基金The Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)the National Natural Science Foundation of China(No.61572258,61103141,51405241)+1 种基金the Natural Science Foundation of Jiangsu Province(No.BK20151530)Overseas Training Programs for Outstanding Young Scholars of Universities in Jiangsu Province
文摘To improve the classification performance of the kernel minimum squared error( KMSE), an enhanced KMSE algorithm( EKMSE) is proposed. It redefines the regular objective function by introducing a novel class label definition, and the relative class label matrix can be adaptively adjusted to the kernel matrix.Compared with the common methods, the newobjective function can enlarge the distance between different classes, which therefore yields better recognition rates. In addition, an iteration parameter searching technique is adopted to improve the computational efficiency. The extensive experiments on FERET and GT face databases illustrate the feasibility and efficiency of the proposed EKMSE. It outperforms the original MSE, KMSE,some KMSE improvement methods, and even the sparse representation-based techniques in face recognition, such as collaborate representation classification( CRC).
基金supported in part by the National Natural Science Foundation of China (11971457)Anhui Provincial Natural Science Foundation (1908085MA06)the Fundamental Research Funds for the Central Universities(WK2040000035)。
基金国家自然科学基金(the National Natural Science Foundation of China under Grant No.60602038)广东省自然科学基金(the Natural Science Foundation of Guangdong Province of China under Grant No.06300862)
基金National Natural Science Foundation of China(Nos.61761027,61261029)
文摘In the measurement of liquid level in industrial site environment,noise interference can affect the measurement accuracy.In order to improve the measurement accuracy of liquid level in the viscous state,a nuclear radiation level measurement system based on the least mean square(LMS)filtering correction method is designed.The system uses STM32F103 as the control core and adopts HART bus HT1200M chip for remote signal transmission and reception.The adaptive LMS algorithm can be used for more accurate filtering,calculating iterative weight vector,updating weighted coefficient,effectively removing system measurement noise and improving the measurement accuracy.The results show that the nuclear radiation level gauge based on normalized LMS can correct the measurement system accuracy in adaptive rules,improve the measurement accuracy to meet the requirements of industrial field environment for liquid level measurement and enhance the industrial automation control degree.
基金Supported by the Fundamental Research Funds for the Central Universities (No. NS2012093)
文摘In this paper, we propose a new method that combines collage error in fractal domain and Hu moment invariants for image retrieval with a statistical method - variable bandwidth Kernel Density Estimation (KDE). The proposed method is called CHK (KDE of Collage error and Hu moment) and it is tested on the Vistex texture database with 640 natural images. Experimental results show that the Average Retrieval Rate (ARR) can reach into 78.18%, which demonstrates that the proposed method performs better than the one with parameters respectively as well as the commonly used histogram method both on retrieval rate and retrieval time.
文摘This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.