As a main channel for the foreign economic cooperation of China nuclear industry,China Zhongyuan Engineering Corporation (CZEC) has been constantly engaged in technical modifications and management innovations in its ...As a main channel for the foreign economic cooperation of China nuclear industry,China Zhongyuan Engineering Corporation (CZEC) has been constantly engaged in technical modifications and management innovations in its exporting nuclear reactor projects.In the implementation of heavy water research reactor contract in Algeria,CZEC had established a complete and adequate design standards system in compliance with the international standards,and made significant modifications to the reference reactor in the aspects of reactor power and reactor safety,solved quite some technical issues which affected the reactor technical performance.The modifications and improvements enabled the technical parameters,safety features,reactor multipurpose application to attain to the advanced level in the world.In the 300 MWe PWR NPPs in Pakistan,safety features had been updated in line with upgrading regulatory requisites.The design philosophy and technology application demonstrated CZEC's creation and innovation on basis of constant safety enhancement of nuclear power projects.Efforts had also been made by CZEC in promoting China made equipment items and components exportation.展开更多
To date, nuclear cogeneration applications have been limited, primarily to district heating in Eastern Europe and heavy water production in Canada. With the current global price for oil and energy, this technology is ...To date, nuclear cogeneration applications have been limited, primarily to district heating in Eastern Europe and heavy water production in Canada. With the current global price for oil and energy, this technology is not economically viable for most countries. However, oil and fossil fuel prices are known to be highly volatile, and the Paris Agreement calls for a reduction in fossil fuel use. Under these circumstances, heat supplied by nuclear power may abruptly return to favor. To prepare for such a scenario, this study will investigate design considerations for a prototypical modem nuclear power plant, the Korean APR1400 (advanced power reactor 1400) (e.g., Shin Kori Units 3, 4, Shin Hanul 1, 2, Barakah Units 1, 2, 3, 4). Nuclear cogeneration can impact balance of plant system and component design for the condensate, feedwater, extraction steam, and heater drain systems. The APR1400 turbine cycle will be reviewed for a parametric range of pressures and flow rates of the steam exported for cogeneration to identify major design challenges.展开更多
To achieve excellent production capability and maintain high security for nuclear power stations, equipment reliability is studied as a key issue. As the main branch, equipment reliability management is considered as ...To achieve excellent production capability and maintain high security for nuclear power stations, equipment reliability is studied as a key issue. As the main branch, equipment reliability management is considered as an effective approach to make plant management strategy and organize routine work. Some achievements on research and application of equipment reliability management at Daya Bay Nuclear Power Station are introduced in this paper. By studying and implementing 1NPO (Institute of Nuclear Power Operations) AP-913 equipment reliability process, reliability-centered maintenance (RCM), critical component management (CCM), and many other similar methods, equipment reliability management system has been established at Daya Bay. And by continuous effort on improving application effect of these technologies, some innovation has also been made. Some innovative products, such as iSOM Intelligent Expert System, reliability and technique centered maintenance (RtCM), predictive maintenance system (PdM), and so on, have been developed. Based on these achievements, Daya Bay Nuclear Power Station has achieved excellent operation performance and won several prizes in WANO (World Association of Nuclear Operators) competition every year.展开更多
Indonesia has been planning to build Nuclear Power Plants (NPPs) since the 1970's. Nevertheless, due to some problems the program is immaterialized so far. Recently, in anticipation of domestic energy crisis, nucle...Indonesia has been planning to build Nuclear Power Plants (NPPs) since the 1970's. Nevertheless, due to some problems the program is immaterialized so far. Recently, in anticipation of domestic energy crisis, nuclear program is revitalized. In the current situation, nuclear program is facing various challenges, including public perception, political instability, brain drain of skilled people, governmental support, and international confidence. In coping with these challenges, several efforts have been done. For instance, to deals with public perception, BATAN is making continuous effort in convincing the public and the decision makers to be aware of the necessity of nuclear power. In line with such effort, several milestones of the nuclear power programme have also been achieved. One of the most important milestones is the enactment of Act No. 10/1997 on Nuclear Energy. The Act demands the establishment of independent regulatory body separated from promoting body.展开更多
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi...This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.展开更多
文摘As a main channel for the foreign economic cooperation of China nuclear industry,China Zhongyuan Engineering Corporation (CZEC) has been constantly engaged in technical modifications and management innovations in its exporting nuclear reactor projects.In the implementation of heavy water research reactor contract in Algeria,CZEC had established a complete and adequate design standards system in compliance with the international standards,and made significant modifications to the reference reactor in the aspects of reactor power and reactor safety,solved quite some technical issues which affected the reactor technical performance.The modifications and improvements enabled the technical parameters,safety features,reactor multipurpose application to attain to the advanced level in the world.In the 300 MWe PWR NPPs in Pakistan,safety features had been updated in line with upgrading regulatory requisites.The design philosophy and technology application demonstrated CZEC's creation and innovation on basis of constant safety enhancement of nuclear power projects.Efforts had also been made by CZEC in promoting China made equipment items and components exportation.
文摘To date, nuclear cogeneration applications have been limited, primarily to district heating in Eastern Europe and heavy water production in Canada. With the current global price for oil and energy, this technology is not economically viable for most countries. However, oil and fossil fuel prices are known to be highly volatile, and the Paris Agreement calls for a reduction in fossil fuel use. Under these circumstances, heat supplied by nuclear power may abruptly return to favor. To prepare for such a scenario, this study will investigate design considerations for a prototypical modem nuclear power plant, the Korean APR1400 (advanced power reactor 1400) (e.g., Shin Kori Units 3, 4, Shin Hanul 1, 2, Barakah Units 1, 2, 3, 4). Nuclear cogeneration can impact balance of plant system and component design for the condensate, feedwater, extraction steam, and heater drain systems. The APR1400 turbine cycle will be reviewed for a parametric range of pressures and flow rates of the steam exported for cogeneration to identify major design challenges.
文摘To achieve excellent production capability and maintain high security for nuclear power stations, equipment reliability is studied as a key issue. As the main branch, equipment reliability management is considered as an effective approach to make plant management strategy and organize routine work. Some achievements on research and application of equipment reliability management at Daya Bay Nuclear Power Station are introduced in this paper. By studying and implementing 1NPO (Institute of Nuclear Power Operations) AP-913 equipment reliability process, reliability-centered maintenance (RCM), critical component management (CCM), and many other similar methods, equipment reliability management system has been established at Daya Bay. And by continuous effort on improving application effect of these technologies, some innovation has also been made. Some innovative products, such as iSOM Intelligent Expert System, reliability and technique centered maintenance (RtCM), predictive maintenance system (PdM), and so on, have been developed. Based on these achievements, Daya Bay Nuclear Power Station has achieved excellent operation performance and won several prizes in WANO (World Association of Nuclear Operators) competition every year.
文摘Indonesia has been planning to build Nuclear Power Plants (NPPs) since the 1970's. Nevertheless, due to some problems the program is immaterialized so far. Recently, in anticipation of domestic energy crisis, nuclear program is revitalized. In the current situation, nuclear program is facing various challenges, including public perception, political instability, brain drain of skilled people, governmental support, and international confidence. In coping with these challenges, several efforts have been done. For instance, to deals with public perception, BATAN is making continuous effort in convincing the public and the decision makers to be aware of the necessity of nuclear power. In line with such effort, several milestones of the nuclear power programme have also been achieved. One of the most important milestones is the enactment of Act No. 10/1997 on Nuclear Energy. The Act demands the establishment of independent regulatory body separated from promoting body.
文摘This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.