The low-cycle loading test of two staggered slab-column-boundary beam joints was carried out to study their seismic performance.The crack development,load-displacement relationship,displacement ductility,and energy di...The low-cycle loading test of two staggered slab-column-boundary beam joints was carried out to study their seismic performance.The crack development,load-displacement relationship,displacement ductility,and energy dissipation performance of the staggered slab-column joints(SSCJ)were studied.Experimental results reveal that both specimens present short-column brittle shear failure.Furthermore,an obvious hysteretic curve pinching phenomenon occurred.Thus,it can be concluded that the seismic performance of the joints is insufficient.These results suggest that the anchorage of the longitudinal reinforcement of the slab in the joint’s core area should be improved,and attention should be paid to the short-column stirrup configuration of the SSCJ.These results can provide a research basis for the design of such joints in future applications.展开更多
The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considerin...The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considering on the influence of semirigidity between steel beams and steel columns, second order effect of beam-column members for steel frame and structural second order effect, the traditional continuum analytial method used in RC shear-frames wall structure is developed to steel frames-reinforced concrete shear wall mixed structure subject to horizontal load in this paper. A continuum approach, which is suitable for analyzing steel frames-reinforced concrete shear wall mixed structure subject to horizontal load, is presented. The method is relatively simple and more practical. It will be referred to structural design for steel frames-reinforced concrete shear wall mixed structure.展开更多
基金The National Natural Science Foundation of China(No.59878013).
文摘The low-cycle loading test of two staggered slab-column-boundary beam joints was carried out to study their seismic performance.The crack development,load-displacement relationship,displacement ductility,and energy dissipation performance of the staggered slab-column joints(SSCJ)were studied.Experimental results reveal that both specimens present short-column brittle shear failure.Furthermore,an obvious hysteretic curve pinching phenomenon occurred.Thus,it can be concluded that the seismic performance of the joints is insufficient.These results suggest that the anchorage of the longitudinal reinforcement of the slab in the joint’s core area should be improved,and attention should be paid to the short-column stirrup configuration of the SSCJ.These results can provide a research basis for the design of such joints in future applications.
文摘The inter-story drift stiffness considered the semirigidity of beam and column joints connection, and P-Delta second order effect of steel frame parts in the mixed structure is presented in the paper. After considering on the influence of semirigidity between steel beams and steel columns, second order effect of beam-column members for steel frame and structural second order effect, the traditional continuum analytial method used in RC shear-frames wall structure is developed to steel frames-reinforced concrete shear wall mixed structure subject to horizontal load in this paper. A continuum approach, which is suitable for analyzing steel frames-reinforced concrete shear wall mixed structure subject to horizontal load, is presented. The method is relatively simple and more practical. It will be referred to structural design for steel frames-reinforced concrete shear wall mixed structure.