期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Ø177.8mm套管大井段细分注水工艺研究应用
1
作者 马威 《石油石化物资采购》 2019年第36期42-42,共1页
177.8mm套管大井段细分注水工艺一直是注水开发的难点,研究认为采用可靠性设计理念,通过合理分层、合理配注,确定可靠分注层段数,改进管柱及测试工艺,定期检修分注管柱等,强化分注管柱工作可靠性,可提高分注工艺水平。
关键词 水管柱 层段数 检分注
下载PDF
Detecting abnormalities for empty nest elder in smart monitoring system
2
作者 杨蕾 杨路明 +1 位作者 满君丰 刘广滨 《Journal of Southeast University(English Edition)》 EI CAS 2008年第3期347-350,共4页
In order to implement the real-time detection of abnormality of elder and devices in an empty nest home,multi-modal joint sensors are used to collect discrete action sequences of behavior,and the improved hierarchical... In order to implement the real-time detection of abnormality of elder and devices in an empty nest home,multi-modal joint sensors are used to collect discrete action sequences of behavior,and the improved hierarchical hidden Markov model is adopted to Abstract these discrete action sequences captured by multi-modal joint sensors into an occupant’s high-level behavior—event,then structure representation models of occupant normality are modeled from large amounts of spatio-temporal data. These models are used as classifiers of normality to detect an occupant’s abnormal behavior.In order to express context information needed by reasoning and detection,multi-media ontology (MMO) is designed to annotate and reason about the media information in the smart monitoring system.A pessimistic emotion model (PEM) is improved to analyze multi-interleaving events of multi-active devices in the home.Experiments demonstrate that the PEM can enhance the accuracy and reliability for detecting active devices when these devices are in blind regions or are occlusive. The above approach has good performance in detecting abnormalities involving occupants and devices in a real-time way. 展开更多
关键词 multi-media ontology semantic annotation abnormality detection hierarchical hidden Markov model pessimistic emotion model
下载PDF
Differential Electrolytic Potentiometric, a Detector for FIA Determination of Procainamide in Pharmaceutical Preparations
3
作者 Safwan Mohammad Fraihat Abdulla Mohammad Abulkibash 《Journal of Chemistry and Chemical Engineering》 2010年第12期7-12,共6页
Differential electrolytic potentiometry (DEP) was coupled with Flow injection analysis (FIA) technique for the determination of Procainamide in pharmaceutical preparations. Platinum electrodes were used as an indi... Differential electrolytic potentiometry (DEP) was coupled with Flow injection analysis (FIA) technique for the determination of Procainamide in pharmaceutical preparations. Platinum electrodes were used as an indicating system to follow the oxidation of Procainamide with cerium(IV), and permanganate in an acidic medium. The oxidation reactions of Procainamide with Ce(IV) and/or permanganate are fast enough to permit its determination by flow injection in sulfuric acid media. The univariate method was employed to optimize the variables such as the current density, the flow rate, the oxidant concentration and the concentration of sulfuric acid. The proposed method was linear in the range 20-100 μg.mL^-1 , the DL and R2 values were 12 μg.mL^-1 and 0.995 respectively. The procedure was applied successfully to the determination of Procainamide in commercial tablets. The results of this study were favorably compared statistically with those obtained with official methods. 展开更多
关键词 Differential electrolytic potentiometry flow injection analysis PROCAINAMIDE oxidation.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部