Castleman's disease (CD) of the pancreas/peripancreas is extremely rare. The recently introduced, endoscopic ultrasonography (EUS)-guided trucut biopsy (TCB) is a useful diagnostic rnodality for obtaining tissu...Castleman's disease (CD) of the pancreas/peripancreas is extremely rare. The recently introduced, endoscopic ultrasonography (EUS)-guided trucut biopsy (TCB) is a useful diagnostic rnodality for obtaining tissue samples from peripancreatic lesions. However, its role in diagnosing CD remains unknown. We report a case of localized, peripancreatic, hyaline-vascular CD biopsied using EUS. The pathology results were initially interpreted as an extranodal, marginal-zone B-cell lyrnphoma. However, polyrnerase chain reaction (PCR) study for the IgH gene rearrangement revealed a polyclonal pattern. We also reviewed the relevant literature. To our knowledge, this is the first illustrated report on EUS-TCB findings of CD with its pathology results of EUS-TCB mimicked a B-cell lymphoma.展开更多
AIM: To compare the liver stiffness (LS) measurement by transient elastography (TE) to the liver biopsy (LB)-considered the "gold standard" in the evaluation of patients with chronic hepatitis C. METHODS: Du...AIM: To compare the liver stiffness (LS) measurement by transient elastography (TE) to the liver biopsy (LB)-considered the "gold standard" in the evaluation of patients with chronic hepatitis C. METHODS: During a period of 12 mo, we evaluated 199 consecutive patients with chronic hepatitis due to hepatitis C virus (HCV), in which LB and LS assessments (by means of TE) were performed during the same session. RESULTS: Out of 199 patients, a valid measurement of the LS could not be obtained in 8. The mean value of LS in the cohort of 191 valid measurements was 8.45 ± 4.96 kPa, ranging from 2.3 to 38 kPa. The mean value of LS in patients with signifi cant fi brosis at biopsy (161 patients with F ≥ 2 according to Metavir) was 9.02 ± 5.15 kPa, significantly higher than in patients with no or mild fi brosis (30 patients with F < 2 Metavir): 5.39 ± 1.81 kPa (P < 0.0001). For a cut- off value of 6.8 kPa, the LS had a PPV of 98%, a NPV of 30.1%, a sensitivity of 59.6% and a specificity of 93.3% for the presence of signifi cant fi brosis (at least F2 Metavir), with a diagnostic performance of 77.3% (AUROC 0.773). Using this cut-off value, we reached the best discrimination between absence of fibrosis/ mild fibrosis (F < 2 Metavir) and the presence ofmoderate to severe fi brosis (F ≥ 2 Metavir). CONCLUSION: In patients with chronic hepatitis due to HCV, a cut-off value of 6.8 kPa measured by TE can differentiate between significant fibrosis and absent or mild fi brosis, with a PPV of 98%, a NPV of 30.1%, a sensitivity of 59.6%, a specificity of 93.3%, and a diagnostic performance of 77.3%.展开更多
AIM: To evaluate the value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas.METHODS: From January 1999 to October 2004, CT-guided core-needle biopsies were performed in 80 patient...AIM: To evaluate the value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas.METHODS: From January 1999 to October 2004, CT-guided core-needle biopsies were performed in 80 patients with suspected malignant lymphoma. Biopsies were performed with an 18-20 G biopsy-cut (CR Bard, Inc., Covington, GA,USA) needle driven by a spring-loaded Bard biopsy gun.RESULTS: A definite diagnosis and accurate histological subtype were obtained in 61 patients with a success rate of 76.25% (61/80). Surgical sampling was performed in 19 patients (23.75%) with non-diagnostic core-needle biopsies. The success rate of CT-guided core-needle biopsy varied with the histopathologic subtypes in our group.The relatively high success rates of core-needle biopsy were noted in diffuse large B-cell non-Hodgkin's lymphoma (NHL, 88.89%) and peripheral T-cell NHL (90%). However,the success rates were relatively low in anaplastic large cell (T/null cell) lymphoma (ALCL, 44.44%) and Hodgkin's disease (HD, 28.57%) in our group.CONCLUSION: CT-guided core-needle biopsy is a reliable means of diagnosing and classifying malignant lymphomas,and can be widely applied in the management of patients with suspected malignant lymphoma.展开更多
AIM: To tattoo gastric mucosa with a novel medical device which could be used to monitor and follow-up gastric mucosal lesions.METHODS: Combining endoscopic biopsy with sclerotherapy injection, we designed a new devic...AIM: To tattoo gastric mucosa with a novel medical device which could be used to monitor and follow-up gastric mucosal lesions.METHODS: Combining endoscopic biopsy with sclerotherapy injection, we designed a new device that could perform biopsy and injection simultaneously. We performed endoscopies on a pig by using a novel endoscope tattoo biopsy forceps for 15 mo. At the same time, we used two-step method combining sclerotherapy injection needle with endoscopic biopsy. The acuity, inflammation and duration of endoscopy were compared between two methods.RESULTS:Compared with the old two-step method,although the inflammation induced by our new device was similar, the duration of procedure was markedly decreased and the acuity of tattooing was better than the old two-step method. All characteristics of the novel device complied with national safety guidelines. Follow-up gastroscopy after 15 mo showed the stained site with injection of 1:100 0.5 mL of India ink was still markedly visible with little inflammatory reaction.CONCLUSION: Endoscopic tattooing biopsy forceps can be widely used in monitoring precancerous lesions.Its safety and effectiveness has been established in animals.展开更多
文摘Castleman's disease (CD) of the pancreas/peripancreas is extremely rare. The recently introduced, endoscopic ultrasonography (EUS)-guided trucut biopsy (TCB) is a useful diagnostic rnodality for obtaining tissue samples from peripancreatic lesions. However, its role in diagnosing CD remains unknown. We report a case of localized, peripancreatic, hyaline-vascular CD biopsied using EUS. The pathology results were initially interpreted as an extranodal, marginal-zone B-cell lyrnphoma. However, polyrnerase chain reaction (PCR) study for the IgH gene rearrangement revealed a polyclonal pattern. We also reviewed the relevant literature. To our knowledge, this is the first illustrated report on EUS-TCB findings of CD with its pathology results of EUS-TCB mimicked a B-cell lymphoma.
文摘AIM: To compare the liver stiffness (LS) measurement by transient elastography (TE) to the liver biopsy (LB)-considered the "gold standard" in the evaluation of patients with chronic hepatitis C. METHODS: During a period of 12 mo, we evaluated 199 consecutive patients with chronic hepatitis due to hepatitis C virus (HCV), in which LB and LS assessments (by means of TE) were performed during the same session. RESULTS: Out of 199 patients, a valid measurement of the LS could not be obtained in 8. The mean value of LS in the cohort of 191 valid measurements was 8.45 ± 4.96 kPa, ranging from 2.3 to 38 kPa. The mean value of LS in patients with signifi cant fi brosis at biopsy (161 patients with F ≥ 2 according to Metavir) was 9.02 ± 5.15 kPa, significantly higher than in patients with no or mild fi brosis (30 patients with F < 2 Metavir): 5.39 ± 1.81 kPa (P < 0.0001). For a cut- off value of 6.8 kPa, the LS had a PPV of 98%, a NPV of 30.1%, a sensitivity of 59.6% and a specificity of 93.3% for the presence of signifi cant fi brosis (at least F2 Metavir), with a diagnostic performance of 77.3% (AUROC 0.773). Using this cut-off value, we reached the best discrimination between absence of fibrosis/ mild fibrosis (F < 2 Metavir) and the presence ofmoderate to severe fi brosis (F ≥ 2 Metavir). CONCLUSION: In patients with chronic hepatitis due to HCV, a cut-off value of 6.8 kPa measured by TE can differentiate between significant fibrosis and absent or mild fi brosis, with a PPV of 98%, a NPV of 30.1%, a sensitivity of 59.6%, a specificity of 93.3%, and a diagnostic performance of 77.3%.
文摘AIM: To evaluate the value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas.METHODS: From January 1999 to October 2004, CT-guided core-needle biopsies were performed in 80 patients with suspected malignant lymphoma. Biopsies were performed with an 18-20 G biopsy-cut (CR Bard, Inc., Covington, GA,USA) needle driven by a spring-loaded Bard biopsy gun.RESULTS: A definite diagnosis and accurate histological subtype were obtained in 61 patients with a success rate of 76.25% (61/80). Surgical sampling was performed in 19 patients (23.75%) with non-diagnostic core-needle biopsies. The success rate of CT-guided core-needle biopsy varied with the histopathologic subtypes in our group.The relatively high success rates of core-needle biopsy were noted in diffuse large B-cell non-Hodgkin's lymphoma (NHL, 88.89%) and peripheral T-cell NHL (90%). However,the success rates were relatively low in anaplastic large cell (T/null cell) lymphoma (ALCL, 44.44%) and Hodgkin's disease (HD, 28.57%) in our group.CONCLUSION: CT-guided core-needle biopsy is a reliable means of diagnosing and classifying malignant lymphomas,and can be widely applied in the management of patients with suspected malignant lymphoma.
基金Supported by the Medical Science Foundation of Zhejiang Province, No.2003A059
文摘AIM: To tattoo gastric mucosa with a novel medical device which could be used to monitor and follow-up gastric mucosal lesions.METHODS: Combining endoscopic biopsy with sclerotherapy injection, we designed a new device that could perform biopsy and injection simultaneously. We performed endoscopies on a pig by using a novel endoscope tattoo biopsy forceps for 15 mo. At the same time, we used two-step method combining sclerotherapy injection needle with endoscopic biopsy. The acuity, inflammation and duration of endoscopy were compared between two methods.RESULTS:Compared with the old two-step method,although the inflammation induced by our new device was similar, the duration of procedure was markedly decreased and the acuity of tattooing was better than the old two-step method. All characteristics of the novel device complied with national safety guidelines. Follow-up gastroscopy after 15 mo showed the stained site with injection of 1:100 0.5 mL of India ink was still markedly visible with little inflammatory reaction.CONCLUSION: Endoscopic tattooing biopsy forceps can be widely used in monitoring precancerous lesions.Its safety and effectiveness has been established in animals.