AC-HVDC-AC energy conversion systems using MMC (modular multilevel converters) are becoming popular to integrate distributed energy systems to the main grid. Such multilevel converters pose a serious problems for H...AC-HVDC-AC energy conversion systems using MMC (modular multilevel converters) are becoming popular to integrate distributed energy systems to the main grid. Such multilevel converters pose a serious problems for HIL (hardware in the loop) simulators required for control, protection design and testing due to the large number of cells that must be simulated individually using very small time steps. This paper demonstrates the advantages of using a very small time step to simulate a MMC topology. The MMC is implemented on FPGA (fiel-programmable gate array) to simulate fast transient with a time step of 250 ns. The AC network and HVDC bus is simulated on the PC, with a slower time step of 10 μs to 20 μs. The simulator architecture and the components simulated on the FPGA and on the PC will be discussed, as well as the method allowing the interconnection of this slow and fast system.展开更多
Regenerative braking is presented in many electric traction applications such as electric and hybrid vehicles, lifts and railway. The regenerated energy can be stored for future use, increasing the efficiency of the s...Regenerative braking is presented in many electric traction applications such as electric and hybrid vehicles, lifts and railway. The regenerated energy can be stored for future use, increasing the efficiency of the system. This paper outlines the benefits of the MMC (modular multilevel converter) in front of the cascaded or series connection of converters to achieve high voltage from low voltage storage elements such as supercapacitors. The paper compares three different solutions and shows that the MMC can benefit from weight and volume reduction of the output inductance when shifted switching modulation strategy is used. Using this modulation strategy, not only the output frequency is increased, but also the magnitude of the inductor applied voltage is reduced, reducing inductor size and volume.展开更多
Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of me...Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of meshed HVDC grids with the PFC is presented,and then,the issue of over-voltage on the thyristor based PFC is described and analyzed.Through the analysis of different operating modes of the full-bridge sub-module,the mechanism of over-voltage ride through of the MMPFC is indicated.The control strategy of the MMPFC,which is used to control branch current and keep capacitor voltage balancing,is elaborated.Finally,the performance on current regulation,bidirectional operation and over-voltage ride through is simulated and verified in a built model with PSCAD/EMTDC.展开更多
This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system...This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of展开更多
文摘AC-HVDC-AC energy conversion systems using MMC (modular multilevel converters) are becoming popular to integrate distributed energy systems to the main grid. Such multilevel converters pose a serious problems for HIL (hardware in the loop) simulators required for control, protection design and testing due to the large number of cells that must be simulated individually using very small time steps. This paper demonstrates the advantages of using a very small time step to simulate a MMC topology. The MMC is implemented on FPGA (fiel-programmable gate array) to simulate fast transient with a time step of 250 ns. The AC network and HVDC bus is simulated on the PC, with a slower time step of 10 μs to 20 μs. The simulator architecture and the components simulated on the FPGA and on the PC will be discussed, as well as the method allowing the interconnection of this slow and fast system.
文摘Regenerative braking is presented in many electric traction applications such as electric and hybrid vehicles, lifts and railway. The regenerated energy can be stored for future use, increasing the efficiency of the system. This paper outlines the benefits of the MMC (modular multilevel converter) in front of the cascaded or series connection of converters to achieve high voltage from low voltage storage elements such as supercapacitors. The paper compares three different solutions and shows that the MMC can benefit from weight and volume reduction of the output inductance when shifted switching modulation strategy is used. Using this modulation strategy, not only the output frequency is increased, but also the magnitude of the inductor applied voltage is reduced, reducing inductor size and volume.
基金supported by the National High Technology Research and Development Program of China("863"Program)(Grant No.2012AA050205)
文摘Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of meshed HVDC grids with the PFC is presented,and then,the issue of over-voltage on the thyristor based PFC is described and analyzed.Through the analysis of different operating modes of the full-bridge sub-module,the mechanism of over-voltage ride through of the MMPFC is indicated.The control strategy of the MMPFC,which is used to control branch current and keep capacitor voltage balancing,is elaborated.Finally,the performance on current regulation,bidirectional operation and over-voltage ride through is simulated and verified in a built model with PSCAD/EMTDC.
文摘This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of