In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every par...In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every part of production. In order to get three-dimensional information of objects, commercial digital camera must be examined. For a long time, digital camera has been examined by DLT. Then there must be a high-precision control field. For realizing surveying without control points, a method for self-calibration is proposed.展开更多
The objective of the study was to evaluate the drug-drug interaction studies of levoceterizine with atenolol. Calibration curve studies of working standard solutions of levocetirizine and atenolol (0.01-0.1 mmol) we...The objective of the study was to evaluate the drug-drug interaction studies of levoceterizine with atenolol. Calibration curve studies of working standard solutions of levocetirizine and atenolol (0.01-0.1 mmol) were scanned. Maxima appeared at 231 nm for levocetirizine and 224 nm for atenolol. The calibration curve obeyed Beer Lambert's Law. Lone availabilities of both the drugs were studied in pH 1, pH 4, pH 7.4 and pH 9 at 37℃ on B.P. (British Pharmacopoeia) dissolution apparatus. To study the drug-drug interaction of levocetirizine (5 mg tablet) and atenolol (100 mg tablet), both the drugs were introduced to the dissolution apparatus in simulated gastric juice (pH 1), pH 4, pH 7.4 and pH 9 at 37℃ at zero time and measured the absorbance maxima of both the drugs at the corresponding wavelength. Graphs were plotted for availability percentage (%) of drug versus time at each set of experiment. The availability percentage (%) of levocetirizine in the buffers of pH simulated to gastric pH 4, pH 7.4 and pH 9 in the presence of atenolol was 436.78%, 376.90%, 436.78% and 436.78%, respectively, but the availability of atenolol was increased up to 214.80%, 212.96%, 214.93% and 231.51% in simulated to gastric pH and in the buffers ofpH 4, pH 7.4 and pH 9, respectively. On the basis of these studies, it is concluded that levocetirizine forms a charge-complex with atenolol; therefore, co-administration of these drugs should be avoided.展开更多
The UAVs (unmanned aerial vehicles) and the use of graphical data files of extension KML (keyhole markup language) have become popular nowadays. The KML files are associated to the Google Earth applications. Devel...The UAVs (unmanned aerial vehicles) and the use of graphical data files of extension KML (keyhole markup language) have become popular nowadays. The KML files are associated to the Google Earth applications. Developed by Microdrone company for planning, overflight simulation and data flight analysis, the program mdCockpit was used in this experiment. The UAV Microdrone's flight path was programmed in two ways: using geo referenced images from Google Earth and entering points coordinates into the program. These points have had their geographical decimal coordinates collected by GPS (global positioning system) (RTK (real time kinematic)) method. The aim here is to describe a way of evaluating the difference between the alternatives of flight planning. A flight path, defined a route with 22 points, was also simulated in the program mdCockpit. The points were collected and saved, while the images captured by the program went automatically forming a georeferenced mosaic. A comparison between the differences of coordinates to each point was made by choosing on the images and also by a RTK positioning. The result was up to 14.20 m to a 100 m flight height. There is a significant change of position and this can result in unwanted over flights in locations or even jeopardizing the safety of air activity.展开更多
This paper presents a detailed analysis of the effects of noise (reverberation) on the focusing performance of de-composition of the time reversal operator (DORT) in a noise-limited case and in a reverberation-limited...This paper presents a detailed analysis of the effects of noise (reverberation) on the focusing performance of de-composition of the time reversal operator (DORT) in a noise-limited case and in a reverberation-limited case, respectively. Quantitative results obtained from simulations and experiments are presented. The results show the DORT method can be effi-ciently applied to target detection with enough source level to yield significant backscatter. For a target placed on the bottom, the influence of the reverberation on the focusing performance is slight. However, distinguishing between a target and constant backscattering returning from strong local clutter on the bottom (false alarms) needs further research.展开更多
文摘In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every part of production. In order to get three-dimensional information of objects, commercial digital camera must be examined. For a long time, digital camera has been examined by DLT. Then there must be a high-precision control field. For realizing surveying without control points, a method for self-calibration is proposed.
文摘The objective of the study was to evaluate the drug-drug interaction studies of levoceterizine with atenolol. Calibration curve studies of working standard solutions of levocetirizine and atenolol (0.01-0.1 mmol) were scanned. Maxima appeared at 231 nm for levocetirizine and 224 nm for atenolol. The calibration curve obeyed Beer Lambert's Law. Lone availabilities of both the drugs were studied in pH 1, pH 4, pH 7.4 and pH 9 at 37℃ on B.P. (British Pharmacopoeia) dissolution apparatus. To study the drug-drug interaction of levocetirizine (5 mg tablet) and atenolol (100 mg tablet), both the drugs were introduced to the dissolution apparatus in simulated gastric juice (pH 1), pH 4, pH 7.4 and pH 9 at 37℃ at zero time and measured the absorbance maxima of both the drugs at the corresponding wavelength. Graphs were plotted for availability percentage (%) of drug versus time at each set of experiment. The availability percentage (%) of levocetirizine in the buffers of pH simulated to gastric pH 4, pH 7.4 and pH 9 in the presence of atenolol was 436.78%, 376.90%, 436.78% and 436.78%, respectively, but the availability of atenolol was increased up to 214.80%, 212.96%, 214.93% and 231.51% in simulated to gastric pH and in the buffers ofpH 4, pH 7.4 and pH 9, respectively. On the basis of these studies, it is concluded that levocetirizine forms a charge-complex with atenolol; therefore, co-administration of these drugs should be avoided.
文摘The UAVs (unmanned aerial vehicles) and the use of graphical data files of extension KML (keyhole markup language) have become popular nowadays. The KML files are associated to the Google Earth applications. Developed by Microdrone company for planning, overflight simulation and data flight analysis, the program mdCockpit was used in this experiment. The UAV Microdrone's flight path was programmed in two ways: using geo referenced images from Google Earth and entering points coordinates into the program. These points have had their geographical decimal coordinates collected by GPS (global positioning system) (RTK (real time kinematic)) method. The aim here is to describe a way of evaluating the difference between the alternatives of flight planning. A flight path, defined a route with 22 points, was also simulated in the program mdCockpit. The points were collected and saved, while the images captured by the program went automatically forming a georeferenced mosaic. A comparison between the differences of coordinates to each point was made by choosing on the images and also by a RTK positioning. The result was up to 14.20 m to a 100 m flight height. There is a significant change of position and this can result in unwanted over flights in locations or even jeopardizing the safety of air activity.
基金Project supported by the National Natural Science Foundation of China (Nos. 60702022 and 60772094)the National Basic Re-search Program (973) of China (No. 5132103ZZT21B)
文摘This paper presents a detailed analysis of the effects of noise (reverberation) on the focusing performance of de-composition of the time reversal operator (DORT) in a noise-limited case and in a reverberation-limited case, respectively. Quantitative results obtained from simulations and experiments are presented. The results show the DORT method can be effi-ciently applied to target detection with enough source level to yield significant backscatter. For a target placed on the bottom, the influence of the reverberation on the focusing performance is slight. However, distinguishing between a target and constant backscattering returning from strong local clutter on the bottom (false alarms) needs further research.