The important effects of local land-sea thermodynamic contrast between the South China Sea (SCS) and Indochina Peninsula on SCS summer monsoon onset are preliminarily studied by using two sets of SSTA tests and two id...The important effects of local land-sea thermodynamic contrast between the South China Sea (SCS) and Indochina Peninsula on SCS summer monsoon onset are preliminarily studied by using two sets of SSTA tests and two ideal tests in s-p regional climate model. The result shows that warm SST in the SCS in winter and spring is favorable for the formation of monsoon circulation throughout all levels of the atmosphere over the sea, which hastens the onset of SCS summer monsoon. The effects of cold SST are generally the opposite. The local land-sea contrast in the SCS is one of the possible reasons for SCS summer monsoon onset. Superposed upon large-scale land-sea thermodynamic differences, it facilitates the formation of out-breaking onset characteristics of SCS summer monsoon in the SCS area.展开更多
Medical ultrasound contrast imaging is a powerful modality undergoing successive developments in the last decade to date Lately, pulse inversion has been used in both ultrasound tissue harmonic and contrast imaging. H...Medical ultrasound contrast imaging is a powerful modality undergoing successive developments in the last decade to date Lately, pulse inversion has been used in both ultrasound tissue harmonic and contrast imaging. However, there was a tradeoff between resolution and penetration. Chirp excitations partially solved the tradeoff, but the chirp setting parameters were not optimized. The present work proposes for the first time combining chirp inversion with ultrasound contrast imaging, with the motivation to improve the contrast, by automatically optimizing the setting parameters of chirp excitation, it is thus an optimal command problem. Linear chirps, 5 μm diameter microbubbles and gradient ascent algorithm were simulated to optimize the chirp setting parameters. Simulations exhibited a gain of 5 dB by automatic optimization of chirp inversion relative to pulse inversion. The automatic optimization process was quite fast. Combining chirp inversion with ultrasound contrast imaging led to a maximum backscattered power permitting high contrast outcomes and optimum parameters.展开更多
基金National Natural Science Foundation of China (40175021 40233037)
文摘The important effects of local land-sea thermodynamic contrast between the South China Sea (SCS) and Indochina Peninsula on SCS summer monsoon onset are preliminarily studied by using two sets of SSTA tests and two ideal tests in s-p regional climate model. The result shows that warm SST in the SCS in winter and spring is favorable for the formation of monsoon circulation throughout all levels of the atmosphere over the sea, which hastens the onset of SCS summer monsoon. The effects of cold SST are generally the opposite. The local land-sea contrast in the SCS is one of the possible reasons for SCS summer monsoon onset. Superposed upon large-scale land-sea thermodynamic differences, it facilitates the formation of out-breaking onset characteristics of SCS summer monsoon in the SCS area.
文摘Medical ultrasound contrast imaging is a powerful modality undergoing successive developments in the last decade to date Lately, pulse inversion has been used in both ultrasound tissue harmonic and contrast imaging. However, there was a tradeoff between resolution and penetration. Chirp excitations partially solved the tradeoff, but the chirp setting parameters were not optimized. The present work proposes for the first time combining chirp inversion with ultrasound contrast imaging, with the motivation to improve the contrast, by automatically optimizing the setting parameters of chirp excitation, it is thus an optimal command problem. Linear chirps, 5 μm diameter microbubbles and gradient ascent algorithm were simulated to optimize the chirp setting parameters. Simulations exhibited a gain of 5 dB by automatic optimization of chirp inversion relative to pulse inversion. The automatic optimization process was quite fast. Combining chirp inversion with ultrasound contrast imaging led to a maximum backscattered power permitting high contrast outcomes and optimum parameters.