The main role of water treatment plants is to supply high-quality safe drinking water. Coagulation is one of the most important stages of surface water treatment. The photometric dispersion analyzer(PDA) is a new opti...The main role of water treatment plants is to supply high-quality safe drinking water. Coagulation is one of the most important stages of surface water treatment. The photometric dispersion analyzer(PDA) is a new optical method for flocculation monitoring, and is feasible to realize coagulation feedback control. The on line modification of the coagulation control system' s set point( or optimum dosing coagulant) has influenced the application of this technology in water treatment plant for a long time. A fuzzy control system incorporating the photometric dispersion analyzer was utilized in this coagulation control system. Proposed is a fuzzy logic inference control system by using Takagi and Sugeno' s fuzzy if-then rule for the self-correction of set point on line. Programmed is the dosing rate fuzzy control system in SIEMENS small-scale programmable logic controller. A 400 L/min middle-scale water treatment plant was utilized to simulate the reaction. With the changes of raw water quality, the set point was modified correctly in time, as well as coagulant dosing rate, and residual turbility before filtration was eligible and stable. Results show that this fuzzy inference and control system performs well on the coagulation control system through PDA.展开更多
In order to overcome difficulty of tuning parameters of fuzzy controller, a chaos optimal design method based on annealing strategy is proposed. First, apply the chaotic variables to search for parameters of fuzzy con...In order to overcome difficulty of tuning parameters of fuzzy controller, a chaos optimal design method based on annealing strategy is proposed. First, apply the chaotic variables to search for parameters of fuzzy contro-(ller,) and transform the optimal variables into chaotic variables by carrier-wave method. Making use of the intrinsic stochastic property and ergodicity of chaos movement to escape from the local minimum and direct optimization searching within global range, an approximate global optimal solution is obtained. Then, the chaos local searching and optimization based on annealing strategy are cited, the parameters are optimized again within the limits of the approximate global optimal solution, the optimization is realized by means of combination of global and partial chaos searching, which can converge quickly to global optimal value. Finally, the third order system and discrete nonlinear system are simulated and compared with traditional method of fuzzy control. The results show that the new chaos optimal design method is superior to fuzzy control method, and that the control results are of high precision, with no overshoot and fast response.展开更多
基金Sponsored by the China Postdoctoral Science Foundation (Grant No. 2003033332)Scientific Research Foundation of Harbin Institute of Technology (Grant No. HIT2002.24)
文摘The main role of water treatment plants is to supply high-quality safe drinking water. Coagulation is one of the most important stages of surface water treatment. The photometric dispersion analyzer(PDA) is a new optical method for flocculation monitoring, and is feasible to realize coagulation feedback control. The on line modification of the coagulation control system' s set point( or optimum dosing coagulant) has influenced the application of this technology in water treatment plant for a long time. A fuzzy control system incorporating the photometric dispersion analyzer was utilized in this coagulation control system. Proposed is a fuzzy logic inference control system by using Takagi and Sugeno' s fuzzy if-then rule for the self-correction of set point on line. Programmed is the dosing rate fuzzy control system in SIEMENS small-scale programmable logic controller. A 400 L/min middle-scale water treatment plant was utilized to simulate the reaction. With the changes of raw water quality, the set point was modified correctly in time, as well as coagulant dosing rate, and residual turbility before filtration was eligible and stable. Results show that this fuzzy inference and control system performs well on the coagulation control system through PDA.
文摘In order to overcome difficulty of tuning parameters of fuzzy controller, a chaos optimal design method based on annealing strategy is proposed. First, apply the chaotic variables to search for parameters of fuzzy contro-(ller,) and transform the optimal variables into chaotic variables by carrier-wave method. Making use of the intrinsic stochastic property and ergodicity of chaos movement to escape from the local minimum and direct optimization searching within global range, an approximate global optimal solution is obtained. Then, the chaos local searching and optimization based on annealing strategy are cited, the parameters are optimized again within the limits of the approximate global optimal solution, the optimization is realized by means of combination of global and partial chaos searching, which can converge quickly to global optimal value. Finally, the third order system and discrete nonlinear system are simulated and compared with traditional method of fuzzy control. The results show that the new chaos optimal design method is superior to fuzzy control method, and that the control results are of high precision, with no overshoot and fast response.