As an environmentally harmless and feasible alternate refrigerant, CO 2 has attracted worldwide attention, especially in the area of automobile air conditioning (AAC). The thermal property of CO 2 and its trans cr...As an environmentally harmless and feasible alternate refrigerant, CO 2 has attracted worldwide attention, especially in the area of automobile air conditioning (AAC). The thermal property of CO 2 and its trans critical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO 2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO 2 AAC system.展开更多
Lateral solid mixing was investigated experimentally in the dense zone of a 900mm×100mm×5.2m rectangular circulating fluidized bed riser.Using heated tracer injection,the lateral solid dispersion was determ...Lateral solid mixing was investigated experimentally in the dense zone of a 900mm×100mm×5.2m rectangular circulating fluidized bed riser.Using heated tracer injection,the lateral solid dispersion was determined by measuring the temperature response at different lateral positions. Furthermore, a one-dimensional dispersion model,which describes the solid mixing in the dense zone,is presented.The experimental results were used to determine the lateral particle dispersion coefficient under various operating conditions. A correlation of dispersion coefficient with bed height, gas velocity,and particle size is also proposed.展开更多
文摘As an environmentally harmless and feasible alternate refrigerant, CO 2 has attracted worldwide attention, especially in the area of automobile air conditioning (AAC). The thermal property of CO 2 and its trans critical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO 2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO 2 AAC system.
文摘Lateral solid mixing was investigated experimentally in the dense zone of a 900mm×100mm×5.2m rectangular circulating fluidized bed riser.Using heated tracer injection,the lateral solid dispersion was determined by measuring the temperature response at different lateral positions. Furthermore, a one-dimensional dispersion model,which describes the solid mixing in the dense zone,is presented.The experimental results were used to determine the lateral particle dispersion coefficient under various operating conditions. A correlation of dispersion coefficient with bed height, gas velocity,and particle size is also proposed.