AIM: To investigate the effect of N-acetyl cysteine (NAC)on acute viral hepatitis (AVH).METHODS: We administered 200 mg oral NAC three times daily (600 mg/day) to the study group and placebo capsules to the control gr...AIM: To investigate the effect of N-acetyl cysteine (NAC)on acute viral hepatitis (AVH).METHODS: We administered 200 mg oral NAC three times daily (600 mg/day) to the study group and placebo capsules to the control group. All patients were hospitalized and diagnosed as AVH. Blood total and direct bilirubin, ALT, AST,alkaline phosphatese, albumin and globulin levels of each patient were measured twice weekly until total bilirubin level dropped under 2 mg/dl, ALT level under 100 U/L, follow up was continued and then the patients were discharged.RESULTS: A total of 41(13 female and 28 male) AVH patients were included in our study. The period for normalization of ALT and total bilirubin in the study group was 19.7±6.9 days and 13.7±8.5 days respectively. In the control group it was 20.4±6.5 days and 16.9±7.8 days respectively (P>0.05).CONCLUSION: NAC administration effected neither the time necessary for normalization of ALT and total bilirubin values nor duration of hospitalization, so we could not suggest NAC for the treatment of icteric AVH cases. However, our results have shown that this drug is not harmful to patients with AVH.展开更多
Objective- To compare the consistency of the results from detecting HIV-1 antibody in the paired urine and serum specimens from drug users by ELISA. Methods: The paired urine and serum specimens from 273 drug users de...Objective- To compare the consistency of the results from detecting HIV-1 antibody in the paired urine and serum specimens from drug users by ELISA. Methods: The paired urine and serum specimens from 273 drug users detained at a detoxification unit were collected, and the HIV-1 antibodies in the specimens of them were screened by urine and serum ELISA kits, respectively. Results: Of 273 serum specimens, 94 ones showed positive reaction and among 94 counterpart urine specimens, 93 ones also appeared positive reaction. Taking the results together,the consistent rate of HIV-1 antibody screened by urine and serum ELISA kits was 99.6%. Conclusion: The urine ELISA kit, which screened HIV-1 antibody of urine showing almost the same results tested by serum ELISA kit, is reliable. It is proposed that urine ELISA be introduced in many fields.展开更多
Based on current research, there are three technologies during the test of bacterial endotoxin of liposomes:(1) extraction of bacterial endotoxin from liposomes;(2) addition of bacterial endotoxin in the process ...Based on current research, there are three technologies during the test of bacterial endotoxin of liposomes:(1) extraction of bacterial endotoxin from liposomes;(2) addition of bacterial endotoxin in the process of recovery test; and(3) elimination of the interference factors from drugs and excipients. In the present study, we pointed out that the key technologies to test bacterial endotoxin from paclitaxel liposome included following steps: extraction of bacterial endotoxins from ethanol-dissolved liposomes; preparation of positive control of recovery solution by adding 0.01 m L standard endotoxins in 1 m L liposome ethanol solution; and the use of 0.5% human albumin to eliminate the interference from detection, and accurate detection of the bacterial endotoxin of liposomes.展开更多
文摘AIM: To investigate the effect of N-acetyl cysteine (NAC)on acute viral hepatitis (AVH).METHODS: We administered 200 mg oral NAC three times daily (600 mg/day) to the study group and placebo capsules to the control group. All patients were hospitalized and diagnosed as AVH. Blood total and direct bilirubin, ALT, AST,alkaline phosphatese, albumin and globulin levels of each patient were measured twice weekly until total bilirubin level dropped under 2 mg/dl, ALT level under 100 U/L, follow up was continued and then the patients were discharged.RESULTS: A total of 41(13 female and 28 male) AVH patients were included in our study. The period for normalization of ALT and total bilirubin in the study group was 19.7±6.9 days and 13.7±8.5 days respectively. In the control group it was 20.4±6.5 days and 16.9±7.8 days respectively (P>0.05).CONCLUSION: NAC administration effected neither the time necessary for normalization of ALT and total bilirubin values nor duration of hospitalization, so we could not suggest NAC for the treatment of icteric AVH cases. However, our results have shown that this drug is not harmful to patients with AVH.
文摘Objective- To compare the consistency of the results from detecting HIV-1 antibody in the paired urine and serum specimens from drug users by ELISA. Methods: The paired urine and serum specimens from 273 drug users detained at a detoxification unit were collected, and the HIV-1 antibodies in the specimens of them were screened by urine and serum ELISA kits, respectively. Results: Of 273 serum specimens, 94 ones showed positive reaction and among 94 counterpart urine specimens, 93 ones also appeared positive reaction. Taking the results together,the consistent rate of HIV-1 antibody screened by urine and serum ELISA kits was 99.6%. Conclusion: The urine ELISA kit, which screened HIV-1 antibody of urine showing almost the same results tested by serum ELISA kit, is reliable. It is proposed that urine ELISA be introduced in many fields.
基金The National Major Scientific and Technological Special Project for"Significant New Drugs Development"of China(Grant No.2015ZX09303001)Sub-task"study on methods for detection and evaluation of pyrogen substances in new preparations"(Grant No.2015ZX093030012002)
文摘Based on current research, there are three technologies during the test of bacterial endotoxin of liposomes:(1) extraction of bacterial endotoxin from liposomes;(2) addition of bacterial endotoxin in the process of recovery test; and(3) elimination of the interference factors from drugs and excipients. In the present study, we pointed out that the key technologies to test bacterial endotoxin from paclitaxel liposome included following steps: extraction of bacterial endotoxins from ethanol-dissolved liposomes; preparation of positive control of recovery solution by adding 0.01 m L standard endotoxins in 1 m L liposome ethanol solution; and the use of 0.5% human albumin to eliminate the interference from detection, and accurate detection of the bacterial endotoxin of liposomes.