期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
轴流压气机非定常气动响应模型分析研究
1
作者 张韬 乔渭阳 +1 位作者 陈伟杰 栾长春 《推进技术》 EI CAS CSCD 北大核心 2023年第2期83-93,共11页
压气机非定常气动响应模型是进行航空发动机气动稳定性分析的基础,本文基于经典的独立叶片动态失速模型,根据压气机基元级做功原理,建立了压气机非定常气动响应模型,推导了压气机非定常气动响应计算公式,并基于多台发动机进气畸变实验... 压气机非定常气动响应模型是进行航空发动机气动稳定性分析的基础,本文基于经典的独立叶片动态失速模型,根据压气机基元级做功原理,建立了压气机非定常气动响应模型,推导了压气机非定常气动响应计算公式,并基于多台发动机进气畸变实验数据确定了非定常气动响应模型的时间常数,数值计算分析了多种形式稳态周向压力畸变对压气机动态响应特性的影响。计算结果表明,动态气动响应模型的二阶系统时间常数分别取τ_(1)=2.5,τ_(2)=2.0较为合适,在相同的进气畸变强度下,低压区范围越大,有效增压比就会越大;在同样低压区范围的情况下,低压区数目越多,有效增压比会越小;而在同样畸变度和低压区范围情况下,低压区向高压区的气流变化越平缓,则有效增压比会越小。本文给出的压气机非定常气动响应模型能准确捕捉到压气机气动响应基本规律。 展开更多
关键词 压气机 动态失速 气动响应模型 进气畸变 气动稳定性 非定常流
下载PDF
Wind-induced responses of super-large cooling towers 被引量:3
2
作者 柯世堂 葛耀君 +2 位作者 赵林 陈少林 Y.Tamura 《Journal of Central South University》 SCIE EI CAS 2013年第11期3216-3228,共13页
Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formula... Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers. 展开更多
关键词 super-large cooling towers wind-induced responses wind vibration coefficients aero-elastic model consistent coupled method
下载PDF
上一页 1 下一页 到第