This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of thi...This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.展开更多
In order to measure the location of medical micro-devices in the gastrointestinal tract, electro-magnetic methods were developed considering the magnetic permeability of human bodies. Two varieties of electromagnetic ...In order to measure the location of medical micro-devices in the gastrointestinal tract, electro-magnetic methods were developed considering the magnetic permeability of human bodies. Two varieties of electromagnetic localization methods have been implemented: one uses direct current(DC) to generate the elec-tromagnetic field, and the other uses alternating current (AC). The two varieties of the localization principle were analyzed and relevant experiments were made. The experiments show that the alternating electromagnetic method acquires higher accuracy, higher stability and wider measurement range.展开更多
文摘This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.
基金the Specialized Research Fundfor the Doctoral Program of Higher Education(No. 20040248033)the National High Technology Research and Development Program (863) of China(No. 2006AA04Z368)
文摘In order to measure the location of medical micro-devices in the gastrointestinal tract, electro-magnetic methods were developed considering the magnetic permeability of human bodies. Two varieties of electromagnetic localization methods have been implemented: one uses direct current(DC) to generate the elec-tromagnetic field, and the other uses alternating current (AC). The two varieties of the localization principle were analyzed and relevant experiments were made. The experiments show that the alternating electromagnetic method acquires higher accuracy, higher stability and wider measurement range.