The flow and the temperature in the threestream mixing flow of the lobed nozzle mixer-ejector with double-wall diffuser are numerically investigated. The domain of computation is divided into sub-domalns according to ...The flow and the temperature in the threestream mixing flow of the lobed nozzle mixer-ejector with double-wall diffuser are numerically investigated. The domain of computation is divided into sub-domalns according to the shapes of the double-plate and lobed nozzle. The three-dimensional body-fitted coordinated grids are generated respectively in these sub-domains by solving Lapalace's equations. Grids are dense on the boundaries and orthogonal at the lobe. The grids of all sub-domains compose the whole grid of the domain. In order to avoid the divergence of the computation as the serious non-orthogonality of the grid from the lobe, the co-located grid, SIMPLEC and Chen-Kim modified k-εturbulence model are applied. The great viscosity, the linear and simultaneous cooperation under-relaxation factors are used to solve the coupling of the fluid and solid. Results show that the air is ejected into the double wall section to form the cooling flow. The wall temperature of the double-wall diffuser is lower than that of the single-wall diffuser. The average wall temperature goes down as the diffuser angle increases at the range of 0~5°,otherwise, the result at the range of 5~10°is opposite.展开更多
文摘The flow and the temperature in the threestream mixing flow of the lobed nozzle mixer-ejector with double-wall diffuser are numerically investigated. The domain of computation is divided into sub-domalns according to the shapes of the double-plate and lobed nozzle. The three-dimensional body-fitted coordinated grids are generated respectively in these sub-domains by solving Lapalace's equations. Grids are dense on the boundaries and orthogonal at the lobe. The grids of all sub-domains compose the whole grid of the domain. In order to avoid the divergence of the computation as the serious non-orthogonality of the grid from the lobe, the co-located grid, SIMPLEC and Chen-Kim modified k-εturbulence model are applied. The great viscosity, the linear and simultaneous cooperation under-relaxation factors are used to solve the coupling of the fluid and solid. Results show that the air is ejected into the double wall section to form the cooling flow. The wall temperature of the double-wall diffuser is lower than that of the single-wall diffuser. The average wall temperature goes down as the diffuser angle increases at the range of 0~5°,otherwise, the result at the range of 5~10°is opposite.