The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed...The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed by conductivity probes to determine the liquid slug length distribution. The data covered both the slug and plug flow regimes. From experimental results, the mean liquid slug lengths were relatively insensitive to gas and liquid flow rates in the higher mixture velocity range. But in the lower mixture velocity range, the mean liquid slug length decreased and then increased with mixture velocity. It shows that the development length of slug flow was longer than x/D=1157. A slug tracking model was adapted to study the evolution of liquid slug length distribution in a horizontal pipeline. In the present model, the wake effect of elongated bubble and the pressure drop due to accel-eration are taken into account and random slug lengths are introduced at the entrance. The results of the model are compared with the measured slug length distributions of slug flow regime. It shows that the predicted mean and maximum slug lengths are in agreement with the experimental data at x/D=1157 and the form of the slug length distributions is also predicted well by the model.展开更多
The prediction of slug frequency has important significance on gas-liquid two-phase flow. A hydrody-namic modei was put forward to evaluate slug frequency for horizontal two-phase flow, based on the dependence of slug...The prediction of slug frequency has important significance on gas-liquid two-phase flow. A hydrody-namic modei was put forward to evaluate slug frequency for horizontal two-phase flow, based on the dependence of slug frequency on the frequency of unstable interfacial wave. Using air and water, experimental verification of the modei was carried out in a large range of flow parameters. Six electrical probes were installed at different positions of a horizontal plexiglass pipe to detect slug frequency development. The pipe is 30m long and its inner diameter is 24 mm. It is observed experimentally that the interfacial wave frequency at the inlet is about l to 3 times the frequency of stable slug. The slug frequencies predicted by the modei fit well with Tronconi (1990) modei and the experimental data. The combination of the hydrodynamic modei and the experimental data results in a conclusion that the frequency of equilibrium liquid slug is approximately half the miniraum frequency of interfacial wave.展开更多
基金Supported by the National Natural Science Foundation of China (No.50536020 and 50323001).
文摘The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed by conductivity probes to determine the liquid slug length distribution. The data covered both the slug and plug flow regimes. From experimental results, the mean liquid slug lengths were relatively insensitive to gas and liquid flow rates in the higher mixture velocity range. But in the lower mixture velocity range, the mean liquid slug length decreased and then increased with mixture velocity. It shows that the development length of slug flow was longer than x/D=1157. A slug tracking model was adapted to study the evolution of liquid slug length distribution in a horizontal pipeline. In the present model, the wake effect of elongated bubble and the pressure drop due to accel-eration are taken into account and random slug lengths are introduced at the entrance. The results of the model are compared with the measured slug length distributions of slug flow regime. It shows that the predicted mean and maximum slug lengths are in agreement with the experimental data at x/D=1157 and the form of the slug length distributions is also predicted well by the model.
基金National Natural Science Foundation of China(No.50206016)
文摘The prediction of slug frequency has important significance on gas-liquid two-phase flow. A hydrody-namic modei was put forward to evaluate slug frequency for horizontal two-phase flow, based on the dependence of slug frequency on the frequency of unstable interfacial wave. Using air and water, experimental verification of the modei was carried out in a large range of flow parameters. Six electrical probes were installed at different positions of a horizontal plexiglass pipe to detect slug frequency development. The pipe is 30m long and its inner diameter is 24 mm. It is observed experimentally that the interfacial wave frequency at the inlet is about l to 3 times the frequency of stable slug. The slug frequencies predicted by the modei fit well with Tronconi (1990) modei and the experimental data. The combination of the hydrodynamic modei and the experimental data results in a conclusion that the frequency of equilibrium liquid slug is approximately half the miniraum frequency of interfacial wave.