期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
栗茶间作茶园主要生态因子特性的研究 被引量:9
1
作者 万云 刘桂华 周敏 《经济林研究》 2009年第3期57-60,共4页
通过定位观测对栗茶间作园的主要生态因子进行比较分析。结果表明:栗茶间作能降低茶园的光照强度,有利于调节茶园的温湿度,并且改善了茶园的土壤性状。在春季和夏季,栗间茶园的光强分别为纯茶园的73.81%、58.51%。温度分别比纯茶园低0.... 通过定位观测对栗茶间作园的主要生态因子进行比较分析。结果表明:栗茶间作能降低茶园的光照强度,有利于调节茶园的温湿度,并且改善了茶园的土壤性状。在春季和夏季,栗间茶园的光强分别为纯茶园的73.81%、58.51%。温度分别比纯茶园低0.4~2.5℃、0.9~3.7℃、相对湿度分别比纯茶园高2.03%~15.75%、4.87%~18.67%。 展开更多
关键词 栗茶间作 光照强度 气温、大气湿度 土壤养分
下载PDF
PRELIMINARY STUDY OF INDOOR FEATURES OF TEMPERATURE AND HUMIDITY FOR ROOMS FACING NORTH-SOUTH IN WINTER IN A LOW-LATITUDE PLATEAU CITY
2
作者 张一平 李佑荣 +2 位作者 王进欣 刘玉洪 马友鑫 《Journal of Tropical Meteorology》 SCIE 2002年第1期85-92,共8页
Analyzing observations of wintertime air temperature in both indoor and outdoor surroundings in Kunming, a city lying in low latitudes, characteristics of temperature and humidity have been studied for the interior of... Analyzing observations of wintertime air temperature in both indoor and outdoor surroundings in Kunming, a city lying in low latitudes, characteristics of temperature and humidity have been studied for the interior of rooms facing north-south under different weather conditions. Significant warming effect has been identified in terms of lowest and daily-mean indoor temperature in the area of Kunming. The heating amplitude ranges from 7.7C to 10.0C and from 4.6C to 5.8C for the interior part of rooms facing the south and from 4.6C to 7.0C and from 1.3C to 4.4C for the interior part of rooms facing the north, respectively for the two elements. The highest air temperature is higher indoor than outdoor for rooms facing the south, but otherwise is usually true for rooms facing the north. Additional findings point out that buildings not only help maintain relatively warm indoor temperature but delay its variation. The diurnal cycle of temperature indoor is smaller and ranges by 40% ~ 48% for south-facing rooms, and by 20% ~ 30% for north-facing rooms, than outdoor, and the highest temperature is about 2 hours late inside the room than outside. It shows how inertly indoor temperature varies. The work also finds that relative humidity is less indoor in southward rooms than in northward ones and difference is the largest on fine days but the smallest when it is overcast. For the diurnal variation, the indoor relative humidity is large at nighttime with small amplitude but small during daytime with large amplitude. The above-presented results can be served as scientific foundation for more research on climate in low-latitude cities and rational design of urban architectures. 展开更多
关键词 orientation of room air temperature and humidity different weather condition WINTER low-latitude plateau city
下载PDF
Verification of the stomatal conductance of Nebbiolo grapevine
3
作者 Stefania PRINO Federico SPANNA Claudio CASSARDO 《Journal of Chongqing University》 CAS 2009年第1期17-24,共8页
Wine is one of the most important Italian export products,and Nebbiolo is one of the most respected Italian grapes. In the summer of 2007,a measurement campaign was carried out in a Nebbiolo vineyard located in Vezza ... Wine is one of the most important Italian export products,and Nebbiolo is one of the most respected Italian grapes. In the summer of 2007,a measurement campaign was carried out in a Nebbiolo vineyard located in Vezza d’Alba,near Cuneo,Italy. Using a gauge of trade gases and some other instruments,we recorded the stomatal conductance and also some physiological parameters useful for estimating the dependence of stomatal conductance on environmental variables. The goal of this experiment was improving the parameterization of grapevine evapotranspiration through the assessment of the stomatal conductance and,in particular,of the functional dependence of the stomatal conductance on the following variables:the photosynthetically active radiation,the atmospheric temperature,the atmospheric moisture deficit,and the carbon dioxide concentration. The observations allowed us to check and,in some cases,to adapt the existing general parameterizations found in literature. The results showed some significant differences with the existing parameterizations concerning the atmospheric temperature,the atmospheric moisture deficit,and the carbon dioxide concentration. The parameterizations obtained in this experiment,although referring to a specific plant and site(namely the Nebbiolo at Vezza d’Alba),could allow assessment of the best environmental conditions under which the Nebbiolo grapevine production is the best,and in future could be tested for other grapevines or climates. 展开更多
关键词 GRAPEVINE EVAPOTRANSPIRATION stomatal conductance photosynthetically active radiation
下载PDF
Analysis of long-term variations of fog and haze in China in recent 50 years and their relations with atmospheric humidity 被引量:80
4
作者 DING YiHui LIU YanJu 《Science China Earth Sciences》 SCIE EI CAS 2014年第1期36-46,共11页
Our analysis of fog and haze observations from the surface weather stations in China in recent 50 years (from 196l to 2011) shows that the number of fog days has experienced two-stage variations, with an increasing ... Our analysis of fog and haze observations from the surface weather stations in China in recent 50 years (from 196l to 2011) shows that the number of fog days has experienced two-stage variations, with an increasing trend before 1980 and a decreasing trend after 1990. Especially, an obvious decreasing trend after 1990 can be clearly seen, which is consistent with the decreas- ing trend of the surface relative humidity. However, the number of haze days has demonstrated an increasing trend. As such, the role of reduction of atmospheric relative humidity in the transition process from fog into haze has been further investigated. It is estimated that the mean relative humidity of haze days is about 69%, lower than previously estimated, which implies that it is more difficult for the haze particles to transform into fog drops. This is possibly one of the major environmental factors leading to the reduction of number of fog days. The threshold of the relative humidity for transition from fog into haze is about 82%, also lower than previously estimated. Thus, the reduction of the surface relative humidity in China mainly due to the in- crease of the surface temperature and the saturation specific humidity may exert an obvious impact on the environmental con- ditions for the formations of fog and haze. In addition, our investigation of the relationship between haze and visibility reveals that with the increase of haze days, the visibility has declined markedly. Since 1961, the mean visibility has dropped from 4-10 to 2-4 kin, about a half of the previous horizontal distance of visibility. 展开更多
关键词 fog and haze VISIBILITY relative humidity transition from fog into haze
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部