With the aim to find an absorbing liquid suitable for the gas cleaning system in the application of gasification unit in a remote area, three types of oil were tested using a bubble column and a wetted wall column. Ai...With the aim to find an absorbing liquid suitable for the gas cleaning system in the application of gasification unit in a remote area, three types of oil were tested using a bubble column and a wetted wall column. Air streams containing toluene vapour with flowrates of 13.6 mL-min1 or 27.6 mL.min^-1 were bubbled through a 50 mL static oil in a glass tube at a temperature of 30 ℃ or 60 ℃. In experiments using the wetted wall column, air streams containing toluene were contacted with a falling thin film ofoil on the outer wall of a column with a diameter of 6.4 cm and two different contacting heights of 60 cm or 80 cm. Toluene concentrations in the air stream were adjusted in the range of 700-3000 ppm corresponding to a typical tars concentration in the producer gas. The phase equilibrium of toluene was represented as values of 1/tl of 326, 220 and 182 respectively for lubrication oil, palm oil and sunflower oil (H is Henry's constant with the toluene concentrations in g.L^-1 for liquid phase and g.Nm^-3 for gas phase). From experiments using the bubble column, it was found that the overall mass transfer coefficient (Kc, a) was in the order of 10.3 cm3-min^-1 and the overall liquid phase mass transfer coefficient (KLa)was about 10.3 cm3.min^-1. Although lubrication oil had a slightly better absorption capacity than the other two tested oils, it had a lower mass trasfer coefficient than that of palm oil. All three proposed oils had a much better absorption capacity and absorption rate than that of water used conventionally as a scrubbing liquid in a small biomass gasification plant.展开更多
In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorpti...In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.展开更多
This study describes the development and validation of a sensitive and reliable method for determination of polybrominated diphenyl ethers(PBDEs)in atmospheric particulate matter using selective pressurized liquid e...This study describes the development and validation of a sensitive and reliable method for determination of polybrominated diphenyl ethers(PBDEs)in atmospheric particulate matter using selective pressurized liquid extraction(SPLE)and gas chromatography–mass spectrometry with a negative chemical ionization(GC-NCI-MS).Extraction and clean-up were performed using PLE with 2 g florisil and 3 g silica placed in the extraction cells.Under optimal conditions,14 PBDEs were extracted at 70℃ using hexane/dichloromethane(50:50,v/v)as solvent.Validation of SPLE returned excellent recoveries for most analytes,with relative standard deviations mostly below20%.Method detection limits ranged from 0.13 to15.38 ng·mL^-1 for the GC-MS analyses.The method was successfully applied to atmospheric particulate matter of Beijing,where analytes were detected in the range of182.79 to 468.99 pg·m^-3.展开更多
An analytical method was developed to quantitatively determine selected monohydroxy metabolites of polycyclic aromatic hydrocarbons(PAHs) in human urine. The procedure included enzymatic hydrolysis to cleave the conju...An analytical method was developed to quantitatively determine selected monohydroxy metabolites of polycyclic aromatic hydrocarbons(PAHs) in human urine. The procedure included enzymatic hydrolysis to cleave the conjugated metabolites, solid-phase microextraction enrichment, and gas chromatography-mass spectrometry analysis. The method proved to be sensitive enough to detect the selected PAH metabolites in human urine.展开更多
文摘With the aim to find an absorbing liquid suitable for the gas cleaning system in the application of gasification unit in a remote area, three types of oil were tested using a bubble column and a wetted wall column. Air streams containing toluene vapour with flowrates of 13.6 mL-min1 or 27.6 mL.min^-1 were bubbled through a 50 mL static oil in a glass tube at a temperature of 30 ℃ or 60 ℃. In experiments using the wetted wall column, air streams containing toluene were contacted with a falling thin film ofoil on the outer wall of a column with a diameter of 6.4 cm and two different contacting heights of 60 cm or 80 cm. Toluene concentrations in the air stream were adjusted in the range of 700-3000 ppm corresponding to a typical tars concentration in the producer gas. The phase equilibrium of toluene was represented as values of 1/tl of 326, 220 and 182 respectively for lubrication oil, palm oil and sunflower oil (H is Henry's constant with the toluene concentrations in g.L^-1 for liquid phase and g.Nm^-3 for gas phase). From experiments using the bubble column, it was found that the overall mass transfer coefficient (Kc, a) was in the order of 10.3 cm3-min^-1 and the overall liquid phase mass transfer coefficient (KLa)was about 10.3 cm3.min^-1. Although lubrication oil had a slightly better absorption capacity than the other two tested oils, it had a lower mass trasfer coefficient than that of palm oil. All three proposed oils had a much better absorption capacity and absorption rate than that of water used conventionally as a scrubbing liquid in a small biomass gasification plant.
基金the support of the National Natural Science Foundation of China(Nos.51674158,51604168 and 51504142)the Natural Science Foundation of Shandong Province(No.ZR2016EEQ18)+2 种基金the SDUST Research Fund(No.2015JQJH105)the Qingdao Postdoctoral Applied Research Project(No.2015204)the Taishan Scholar Talent Team Support Plan for Advantaged&Unique Discipline Areas
文摘In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.
基金supported by the National Natural Science Foundation of China(41325010)
文摘This study describes the development and validation of a sensitive and reliable method for determination of polybrominated diphenyl ethers(PBDEs)in atmospheric particulate matter using selective pressurized liquid extraction(SPLE)and gas chromatography–mass spectrometry with a negative chemical ionization(GC-NCI-MS).Extraction and clean-up were performed using PLE with 2 g florisil and 3 g silica placed in the extraction cells.Under optimal conditions,14 PBDEs were extracted at 70℃ using hexane/dichloromethane(50:50,v/v)as solvent.Validation of SPLE returned excellent recoveries for most analytes,with relative standard deviations mostly below20%.Method detection limits ranged from 0.13 to15.38 ng·mL^-1 for the GC-MS analyses.The method was successfully applied to atmospheric particulate matter of Beijing,where analytes were detected in the range of182.79 to 468.99 pg·m^-3.
基金supported by the National Natural Science Foundation of China(21227006,21275088)the China Equipment and Education Resources System(CERS-1-75)
文摘An analytical method was developed to quantitatively determine selected monohydroxy metabolites of polycyclic aromatic hydrocarbons(PAHs) in human urine. The procedure included enzymatic hydrolysis to cleave the conjugated metabolites, solid-phase microextraction enrichment, and gas chromatography-mass spectrometry analysis. The method proved to be sensitive enough to detect the selected PAH metabolites in human urine.