In the infrared spectrum absorbed type gas concentration sensor,voltage signal obtained from the two-channel thermopile infrared detector TPS2534 is very weak.In order to solve this problem,the authors have establishe...In the infrared spectrum absorbed type gas concentration sensor,voltage signal obtained from the two-channel thermopile infrared detector TPS2534 is very weak.In order to solve this problem,the authors have established the structure of the sensor and designed weak signal detecting circuit of the sensor based on infrared spectrum absorption principle,differential de-noising principle and weak signal detecting principle.The authors have made experiments using CH4 gas.The results show that the circuit can remove noise effectively and detect weak electrical signal obtained from the detector.展开更多
In the field of near infrared H2O sensing, the acquisition of the absorption signal usually is from a noisy background, thus it is important to adopt an effective signal demodulation method. This study introduced the ...In the field of near infrared H2O sensing, the acquisition of the absorption signal usually is from a noisy background, thus it is important to adopt an effective signal demodulation method. This study introduced the research progress in the field of trace water vapor detection, covering different individual gas detection techniques. On the basis of the conventional double-beam differential absorption, the division method in voltage and the dual-peak method based on the differential value of two adjacent absorption lines have been studied. Voltage division has an excellent stability to temperature variation, mechanical extrusion, and fiber bend loss. The dual-peak method proved a linear relation with the water vapor concentration, and this method provided a way to measure the concentration at high pressure. Furthermore, the so called balanced ratiometer detection (BRD) was introduced. It has an outstanding self-adjusting capability, and it can also avoid an excess phase difference caused by the current-to-voltage converting circuit, thus this method has a high sensitivity. In addition, the second harmonic technique applied to gas detection was introduced, and for the high-frequency modulation via driving current, l/f was suppressed apparently; as a result, this technique realized a better sensitive detection by one to two orders of magnitude.展开更多
文摘In the infrared spectrum absorbed type gas concentration sensor,voltage signal obtained from the two-channel thermopile infrared detector TPS2534 is very weak.In order to solve this problem,the authors have established the structure of the sensor and designed weak signal detecting circuit of the sensor based on infrared spectrum absorption principle,differential de-noising principle and weak signal detecting principle.The authors have made experiments using CH4 gas.The results show that the circuit can remove noise effectively and detect weak electrical signal obtained from the detector.
基金This work was supported by the Natural Science Foundation of China (60977058 & 61307101), Independent Innovation Foundation of Shandong University (IIFSDU2012JC015), the key technology projects of Shandong Province (2010GGX10137), and promotive research fund for excellent young and middle-aged scientists of Shandong Province (BS2010DX028).
文摘In the field of near infrared H2O sensing, the acquisition of the absorption signal usually is from a noisy background, thus it is important to adopt an effective signal demodulation method. This study introduced the research progress in the field of trace water vapor detection, covering different individual gas detection techniques. On the basis of the conventional double-beam differential absorption, the division method in voltage and the dual-peak method based on the differential value of two adjacent absorption lines have been studied. Voltage division has an excellent stability to temperature variation, mechanical extrusion, and fiber bend loss. The dual-peak method proved a linear relation with the water vapor concentration, and this method provided a way to measure the concentration at high pressure. Furthermore, the so called balanced ratiometer detection (BRD) was introduced. It has an outstanding self-adjusting capability, and it can also avoid an excess phase difference caused by the current-to-voltage converting circuit, thus this method has a high sensitivity. In addition, the second harmonic technique applied to gas detection was introduced, and for the high-frequency modulation via driving current, l/f was suppressed apparently; as a result, this technique realized a better sensitive detection by one to two orders of magnitude.