A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubb...A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubble frequency and bubble interface velocity. The authors paid special attention to the probe design and construction for minimizing measurement errors. Measures were also taken in the design of sensor ends for preventing corrosions in the flow. This is an effort to improve the current double-sensor probe technique to meet the ever-increasing needs to local parameter measurements in gas-liquid two-phase flows.展开更多
In this paper, the equilibrium surface tension and the dynamic surface tension of aqueous Triton X-100 solution at temperature 25 ℃ were measured by means of Wilhelmy plate method and maximal bubble pressure method r...In this paper, the equilibrium surface tension and the dynamic surface tension of aqueous Triton X-100 solution at temperature 25 ℃ were measured by means of Wilhelmy plate method and maximal bubble pressure method respectively. The determined critical micellar concentration(cmc) of Triton X-100 at 25 ℃ is (2.2×10-4) mol/dm3. The adsorption mechanics of Triton X-100 at air/solution was determined. For the submicellar concentrations it is diffusion-controlled. The diffusion coefficient was calculated from the experimental data in the range of short limit. In the range of long time adsorption, the subsurface concentration is fitted from the measured dynamic surface tensions.展开更多
基金Supported by the National Natural Science Foundation of China(No.59876032)and the Doctorate Foundation of Xi'an Jiaotong University(DFXJU-17).
文摘A double-sensor probe was used to measure local interfacial parameters of a gas-liquid bubbly flow in a horizontal tube. The parameters included void fraction, interfacial concentration, bubble size distribution, bubble frequency and bubble interface velocity. The authors paid special attention to the probe design and construction for minimizing measurement errors. Measures were also taken in the design of sensor ends for preventing corrosions in the flow. This is an effort to improve the current double-sensor probe technique to meet the ever-increasing needs to local parameter measurements in gas-liquid two-phase flows.
文摘In this paper, the equilibrium surface tension and the dynamic surface tension of aqueous Triton X-100 solution at temperature 25 ℃ were measured by means of Wilhelmy plate method and maximal bubble pressure method respectively. The determined critical micellar concentration(cmc) of Triton X-100 at 25 ℃ is (2.2×10-4) mol/dm3. The adsorption mechanics of Triton X-100 at air/solution was determined. For the submicellar concentrations it is diffusion-controlled. The diffusion coefficient was calculated from the experimental data in the range of short limit. In the range of long time adsorption, the subsurface concentration is fitted from the measured dynamic surface tensions.