Traditional methods for detecting lactoperoxidase (LP) are complex and time-consuming, so a test strip was made based on the enzymatic reaction principle to enable quick and convenient detection of LP in raw milk. I...Traditional methods for detecting lactoperoxidase (LP) are complex and time-consuming, so a test strip was made based on the enzymatic reaction principle to enable quick and convenient detection of LP in raw milk. In this study 0.1 mol/L citric acid (CA)/0.2 mol/L disodium hydrogen phosphate (NAP) buffer solution (pH 5.0), 22 mmol/L 3,3',5,5'-tetramethylbenzidine (TMB), 0.6 mmol/L hydrogen peroxide (H202), and 0.5% Tween-20 or 0.3% cetyltri- methyl ammonium bromide (CTAB) were optimal for preparing a quick, sensitive, and accurate LP test strip. The coefficient of variation (CV) of the estimated LP concentrations ranged from 2.47% to 6.72% and the minimum LP concentration detected by the test strip was 1-2 mg/L. Estimates of active LP in sixteen raw milk samples obtained using the test strip or the TMB method showed a good correlation (c=0.9776). So the test strip provides a quick, convenient, and accurate method for detecting the LP concentration of raw milk.展开更多
基金supported by the National "Twelfth Five-Year" Plan for Science and Technology Support Program of China(No.2013BAD18B06)the Open Research Fund for the Key Laboratory of Dairy Science of Northeast Agricultural University(No.KLDS201201)the Innovative Research Team of Higher Education of Heilongjiang Province(No.2010td11),China
文摘Traditional methods for detecting lactoperoxidase (LP) are complex and time-consuming, so a test strip was made based on the enzymatic reaction principle to enable quick and convenient detection of LP in raw milk. In this study 0.1 mol/L citric acid (CA)/0.2 mol/L disodium hydrogen phosphate (NAP) buffer solution (pH 5.0), 22 mmol/L 3,3',5,5'-tetramethylbenzidine (TMB), 0.6 mmol/L hydrogen peroxide (H202), and 0.5% Tween-20 or 0.3% cetyltri- methyl ammonium bromide (CTAB) were optimal for preparing a quick, sensitive, and accurate LP test strip. The coefficient of variation (CV) of the estimated LP concentrations ranged from 2.47% to 6.72% and the minimum LP concentration detected by the test strip was 1-2 mg/L. Estimates of active LP in sixteen raw milk samples obtained using the test strip or the TMB method showed a good correlation (c=0.9776). So the test strip provides a quick, convenient, and accurate method for detecting the LP concentration of raw milk.