Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model...Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model of marine steam generator feedwater control system was developed which includes mathematical models of two steam generators and parallel turbine-driven feed pumps as well as mathematical models of feedwater pipes and feed regulating valves. The operating condition points of the parallel ttu-bine-driven feed pumps were calculated by the Chebyshev curve fit method. A water level controller for the steam generator and a rotary speed controller for the turbine-driven feed pumps were also included in the model. The accuracy of the mathematical models and their controllers was verified by comparing their results with those from a simulator.展开更多
Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level ...Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.展开更多
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no...An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.展开更多
Conversion of methane by steam reforming was carried out by means of dielectric-barrier discharge.A systemic procedure was employed to determine the suitable experimental conditions.It was found that one of the plasma...Conversion of methane by steam reforming was carried out by means of dielectric-barrier discharge.A systemic procedure was employed to determine the suitable experimental conditions.It was found that one of the plasma generators can match the system best.A higher power input can always bring a higher conversion,but the selectivity to C2H6 decreased from 52.48% to 39.43% as the power increased from 20W to 49W.When discharge distance was 4mm,selectivities to almost all main products reached the max.The inner electrode made of stainless steel and the outer electrode with aluminum foil were one of the best options which can obviously enhance the conversion of methane.A larger flow rate always resulted in a lower conversion of methane.In the most time,19.93% steam promoted conversion of methane.展开更多
This paper presents some opportunities to improve feedwater system efficiency for industrial boilers, usually consisting of multistage centrifugal pumps driven by three-phase induction motors. There is abundant litera...This paper presents some opportunities to improve feedwater system efficiency for industrial boilers, usually consisting of multistage centrifugal pumps driven by three-phase induction motors. There is abundant literature on the efficiency in steam boilers. However, few deal exclusively with feedwater systems. The total horsepower in boiler feed pumps and the corresponding energy consumption estimated for Brazilian industries are as follows: 110.5 MWE of motor driven power and a yearly electricity consumption of 442 GWh for a population of 7,800 steam boilers, approximately. It is estimated that there can be an efficiency improvement in feedwater systems for industrial boilers of 30% on average. To a large extent, these opportunities reside in older boilers that are very common in the Brazilian industrial sector. The most common causes for the low efficiency of feedwater systems are: the control loop of the feedwater, oversized boilers and excessive operational pressure set. Sometimes, the boiler feedwater system can present more than one problem simultaneously. Any kind of solution involves some speed regulation, new pump and number of pumps. Each problem generation facilities were selected in which common inefficiencies cases, the improvement in efficiency can get to 37%. form of intervention in boiler feed pumps, such as: impeller trim, may have more than one solution. Three distinct industrial steam are present. The suggested solutions were analyzed. In these three展开更多
文摘Parallel turbine-driven feedwater pumps are needed when ships travel at high speed. In order to study marine steam generator feedwater control systems which use parallel turbine-driven feed pumps, a mathematical model of marine steam generator feedwater control system was developed which includes mathematical models of two steam generators and parallel turbine-driven feed pumps as well as mathematical models of feedwater pipes and feed regulating valves. The operating condition points of the parallel ttu-bine-driven feed pumps were calculated by the Chebyshev curve fit method. A water level controller for the steam generator and a rotary speed controller for the turbine-driven feed pumps were also included in the model. The accuracy of the mathematical models and their controllers was verified by comparing their results with those from a simulator.
基金Project(51276023) supported by the National Natural Science Foundation of ChinaProject(09k069) supported by the Open Project Funded by Universities Innovation Platform, Hunan Province, ChinaProject(2011GK311) supported by the Office of Science and Technology of Hunan Province, China
文摘Drum level sloshing is the latest discovery in the application of heat recovery steam generator (HRSG) in combined cycle, and shows certain negative influence on drum level controlling. In order to improve drum level controlling, influence factors on the drum level sloshing were investigated. Firstly, drum sub-modules were developed using the method of modularization modeling, and then the model of drum level sloshing was set up as well. Experiments were carried out on the experimental rig, and the model was validated using the obtained experimental results. Dynamic simulation was made based on the model to get a 3-D graph of drum level sloshing, which shows a vivid procedure of drum level sloshing. The effect of feed-water flow rate, main-steam flow rate and heating quantity on the drum level sloshing was analyzed. The simulation results indicate that the signals with frequency higher than 0.05 Hz are that of drum level sloshing, the signals with frequency of 0.0-0.05 Hz are that of drum level trendy and "false water level", and variation of the feed-water flow rates, main-steam flow rates and heating quantities can change the frequency of drum level sloshing, i.e., the frequency of sloshing increases with the increase of feed-water flow rate, or the decrease of the main-steam flow rate and the heating quantity. This research work is fundamental to improve signal-to-noise ratio of drum level signal and precise controlling of drum level.
基金Supported by National Natural Science Foundation of China (No. 50376044)
文摘An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.
基金Supported by the National iqatural Science Foundation of China (20606023, 20490203).
文摘Conversion of methane by steam reforming was carried out by means of dielectric-barrier discharge.A systemic procedure was employed to determine the suitable experimental conditions.It was found that one of the plasma generators can match the system best.A higher power input can always bring a higher conversion,but the selectivity to C2H6 decreased from 52.48% to 39.43% as the power increased from 20W to 49W.When discharge distance was 4mm,selectivities to almost all main products reached the max.The inner electrode made of stainless steel and the outer electrode with aluminum foil were one of the best options which can obviously enhance the conversion of methane.A larger flow rate always resulted in a lower conversion of methane.In the most time,19.93% steam promoted conversion of methane.
文摘This paper presents some opportunities to improve feedwater system efficiency for industrial boilers, usually consisting of multistage centrifugal pumps driven by three-phase induction motors. There is abundant literature on the efficiency in steam boilers. However, few deal exclusively with feedwater systems. The total horsepower in boiler feed pumps and the corresponding energy consumption estimated for Brazilian industries are as follows: 110.5 MWE of motor driven power and a yearly electricity consumption of 442 GWh for a population of 7,800 steam boilers, approximately. It is estimated that there can be an efficiency improvement in feedwater systems for industrial boilers of 30% on average. To a large extent, these opportunities reside in older boilers that are very common in the Brazilian industrial sector. The most common causes for the low efficiency of feedwater systems are: the control loop of the feedwater, oversized boilers and excessive operational pressure set. Sometimes, the boiler feedwater system can present more than one problem simultaneously. Any kind of solution involves some speed regulation, new pump and number of pumps. Each problem generation facilities were selected in which common inefficiencies cases, the improvement in efficiency can get to 37%. form of intervention in boiler feed pumps, such as: impeller trim, may have more than one solution. Three distinct industrial steam are present. The suggested solutions were analyzed. In these three